Yue Zhang
Yue Zhang has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Li Zhu
School of Equipment Management and Support, Engineering University of PAP, Xi’an 710086, China
1 shared publication - Xiaofeng Hu
National Key Laboratory of Electromagnetic Environmental Effects, Army Engineering University, Shijiazhuang 050003, China
1 shared publication - Yu Dong
Storage and Supply Center, Shijiazhuang 050000, China
1 shared publication
Latest Publications
- Open Access
- 5 December 2022
- Published by MDPI AG in Electronics
- Vol. 11 (23) , 4034
Improved High-Order Cumulant TDE Parameter Accumulation Algorithm for Locating UHF Signals of Pulsed Electromagnetic Source
Ultra-high frequency (UHF) signal detection is one of the most effective methods for spatial orientation and partial discharge fault diagnosis. However, when the background noise, especially Gaussian white noise and narrow-band interference, is very high, or the detection region is remote, location accuracy may decrease. To improve this, a location system based on the improved higher-order cumulant time delay estimation (TDE) method combined with energy accumulation is proposed. In the system, the UHF waves are received by a four-antenna array. Improved fourth-order cumulants with a smoothed coherence transform (SCOT) window are used in the TDE, by which Gaussian white noise and narrow-band interference can be efficiently suppressed. The energy accumulation algorithm is applied to the cross-correlation results, by which the accuracy of TDE can be enhanced. The applicability of the proposed localization algorithm is evaluated by simulation and experiment. The simulation results show that the improved fourth-order cumulant TDE-parameter accumulation algorithm is superior in accuracy to traditional location methods. In the experimental measurements, two partial discharge measurement points located in a complex electromagnetic environment are tested. The results illustrate that the proposed method can effectively suppress Gaussian white and narrow-band noise, and the location results can satisfy accuracy requirements when the measurement point is within 70 m.
- 5 December 2022
- Published by MDPI AG in Electronics
- Vol. 11 (23) , 4034
Open AccessImproved High-Order Cumulant TDE Parameter Accumulation Algorithm for Locating UHF Signals of Pulsed Electromagnetic Source
Ultra-high frequency (UHF) signal detection is one of the most effective methods for spatial orientation and partial discharge fault diagnosis. However, when the background noise, especially Gaussian white noise and narrow-band interference, is very high, or the detection region is remote, location accuracy may decrease. To improve this, a location system based on the improved higher-order cumulant time delay estimation (TDE) method combined with energy accumulation is proposed. In the system, the UHF waves are received by a four-antenna array. Improved fourth-order cumulants with a smoothed coherence transform (SCOT) window are used in the TDE, by which Gaussian white noise and narrow-band interference can be efficiently suppressed. The energy accumulation algorithm is applied to the cross-correlation results, by which the accuracy of TDE can be enhanced. The applicability of the proposed localization algorithm is evaluated by simulation and experiment. The simulation results show that the improved fourth-order cumulant TDE-parameter accumulation algorithm is superior in accuracy to traditional location methods. In the experimental measurements, two partial discharge measurement points located in a complex electromagnetic environment are tested. The results illustrate that the proposed method can effectively suppress Gaussian white and narrow-band noise, and the location results can satisfy accuracy requirements when the measurement point is within 70 m.
- Open Access
- 1 May 2016
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 52 (10) , 859-861
Short‐wave infrared photodetector with high responsivity and signal‐to‐noise ratio
Short‐wave infrared photodetectors with a p‐charge layer and double barrier structure are designed and fabricated by molecular beam epitaxy. The current intensity is lowered by three orders of magnitude compared with the detector without the p‐charge layer. The tested responsivity of the detector is 485 A/W at 0.31 V, when the power of the incident light is 10 nW. By adding the p‐charge layer, the signal‐to‐noise ratio of the detector is promoted by 30 times, which reaches 1712 at 0.3 V, when the power of the incident light is 1 nW.
- 1 May 2016
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 52 (10) , 859-861
Open AccessShort‐wave infrared photodetector with high responsivity and signal‐to‐noise ratio
Short‐wave infrared photodetectors with a p‐charge layer and double barrier structure are designed and fabricated by molecular beam epitaxy. The current intensity is lowered by three orders of magnitude compared with the detector without the p‐charge layer. The tested responsivity of the detector is 485 A/W at 0.31 V, when the power of the incident light is 10 nW. By adding the p‐charge layer, the signal‐to‐noise ratio of the detector is promoted by 30 times, which reaches 1712 at 0.3 V, when the power of the incident light is 1 nW.