Xiujun Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xiujun Liu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Zhanguo Ma
State Key Laboratory for Geomechanics and Deep Underground Engineering, China University of Mining and Technology, Xuzhou, China
2 shared publications- Zhanguo Ma
State Key Laboratory of Intelligent Construction and Healthy Operation, Maintenance of Deep Underground Engineering, China University of Mining and Technology, Xuzhou, China
2 shared publications - Dongyang Zhang
School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, 430070, China
1 shared publication - Jun Yuan
College of Chemistry and Chemical Engineering Central South University Changsha China
1 shared publication - Wenchao Huang
Key State Laboratory of Advanced Technology for Materials Synthesis and Processing School of Materials Science and Engineering Wuhan University of Technology Wuhan China
1 shared publication Xiangda Liu
School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, 430070, China
1 shared publication
Latest Publications
- 29 May 2024
- Published by Elsevier in Materials Today Energy
- Vol. 44, 101614
A semitransparent organic solar cell with a bifacial factor of 99.1%
- 29 May 2024
- Published by Elsevier in Materials Today Energy
- Vol. 44, 101614
A semitransparent organic solar cell with a bifacial factor of 99.1%
- 1 February 2023
- Published by Springer Nature in Arabian Journal of Geosciences
- Vol. 16 (2) , 1-11
Mechanical behavior analysis of vertical fully grouted anchor under pullout load
- 1 February 2023
- Published by Springer Nature in Arabian Journal of Geosciences
- Vol. 16 (2) , 1-11
Mechanical behavior analysis of vertical fully grouted anchor under pullout load
- Open Access
- 9 January 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-23
Mechanical behavior analysis of fully grouted bolt under axial load
Based on the idea of discretization and the force balance analysis of each mass spring element, a spring-element analysis method for bolt is proposed. By analyzing the mechanical behavior of the bond interface of the fully grouted bolt, three coupling models of the bond interface, the slider model, the spring model and the spring-slider model, are proposed. Using the spring-element method, five load transfer models, namely the slider model, the spring model, the modified spring model, the spring-pulled slider model, and the spring-slider model, were deduced. And get the bolt displacement distribution function, axial force distribution function and shear stress distribution function under each model. The five proposed models are verified, analyzed and discussed by using the pull-out test of the smooth steel bolt and the threaded steel bolt. It is verified by experiments that this study is helpful to comprehensively understand the mechanical behavior of fully grouted bolts under axial load. The proposed spring element analysis method is simple and easy to understand and the results are reasonable.
- 9 January 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-23
Open AccessMechanical behavior analysis of fully grouted bolt under axial load
Based on the idea of discretization and the force balance analysis of each mass spring element, a spring-element analysis method for bolt is proposed. By analyzing the mechanical behavior of the bond interface of the fully grouted bolt, three coupling models of the bond interface, the slider model, the spring model and the spring-slider model, are proposed. Using the spring-element method, five load transfer models, namely the slider model, the spring model, the modified spring model, the spring-pulled slider model, and the spring-slider model, were deduced. And get the bolt displacement distribution function, axial force distribution function and shear stress distribution function under each model. The five proposed models are verified, analyzed and discussed by using the pull-out test of the smooth steel bolt and the threaded steel bolt. It is verified by experiments that this study is helpful to comprehensively understand the mechanical behavior of fully grouted bolts under axial load. The proposed spring element analysis method is simple and easy to understand and the results are reasonable.
- Open Access
Mechanical Behavior Analysis of Fully Grouted Ground Anchor in Soft-Hard Alternating Stratum
Assuming that the ground anchor is connected with the rock–soil of the sidewall by a tangential linear spring, the load transfer model of the fully grouted ground anchor is established by using the spring element method, and the analytical solutions of the displacement, axial force, and shear stress distribution of the ground anchor in the upper and lower parallel strata foundation and sandwich foundation are given, respectively. Corresponding to the above two kinds of alternating strata, the mechanical behavior of the vertical fully grouted ground anchor in the soft–hard alternating stratum is analyzed using the four conditions in Case 1 and the six conditions in Case 2, respectively. Through the case analysis, it can be concluded that the mechanical behavior of the round anchor is greatly affected by the shear modulus of the shallow stratum, and is less affected by the shear modulus of the deep stratum. The depth of the stratum interface and the thickness of the interlayer have some influence on the mechanical behavior of the whole ground anchor but have little influence on the displacement and axial force distribution of the ground anchor. This paper has certain guidance and reference significance for the design of vertical fully grouted ground anchors in the alternating strata.
Open AccessMechanical Behavior Analysis of Fully Grouted Ground Anchor in Soft-Hard Alternating Stratum
Assuming that the ground anchor is connected with the rock–soil of the sidewall by a tangential linear spring, the load transfer model of the fully grouted ground anchor is established by using the spring element method, and the analytical solutions of the displacement, axial force, and shear stress distribution of the ground anchor in the upper and lower parallel strata foundation and sandwich foundation are given, respectively. Corresponding to the above two kinds of alternating strata, the mechanical behavior of the vertical fully grouted ground anchor in the soft–hard alternating stratum is analyzed using the four conditions in Case 1 and the six conditions in Case 2, respectively. Through the case analysis, it can be concluded that the mechanical behavior of the round anchor is greatly affected by the shear modulus of the shallow stratum, and is less affected by the shear modulus of the deep stratum. The depth of the stratum interface and the thickness of the interlayer have some influence on the mechanical behavior of the whole ground anchor but have little influence on the displacement and axial force distribution of the ground anchor. This paper has certain guidance and reference significance for the design of vertical fully grouted ground anchors in the alternating strata.
- Open Access
Mechanical Behavior Analysis of Fully Grouted Bolts under Axial Cyclic Load
Fully grouted bolts are widely used in engineering. In order to deeply understand the load-transfer mechanism of a fully grouted bolt, it is necessary to analyze and study its mechanical behavior under axial cyclic load. First of all, based on the idea of discretization and the force balance analysis of each mass spring element, this study proposes a method for analyzing the force of the bolt—the spring element method. Second, the load-transfer model of the fully grouted bolt is established by using the spring element method, assuming that the bolt and the sidewall rock and soil are connected by tangential linear springs. The analytical solutions for the displacement, axial force, and shear-stress distribution of the bolt before and after the damage of the sidewall spring are given. It is found that the analysis results of the analytical model proposed in this paper have a great relationship with λ, which is the square root of the ratio of sidewall spring stiffness k′u to bolt stiffness ku. Further analysis found that this model is more suitable for the two working conditions of λ ≈ 0 and λ ≈ 1, and the relationship between sidewall spring stiffness k′u and pull-out stiffness K of the bolt was established under these two working conditions. Finally, the rationality and accuracy of the analytical model proposed in this study are verified by an analysis of two typical test cases under the two working conditions of λ ≈ 0 and λ ≈ 1.
Open AccessMechanical Behavior Analysis of Fully Grouted Bolts under Axial Cyclic Load
Fully grouted bolts are widely used in engineering. In order to deeply understand the load-transfer mechanism of a fully grouted bolt, it is necessary to analyze and study its mechanical behavior under axial cyclic load. First of all, based on the idea of discretization and the force balance analysis of each mass spring element, this study proposes a method for analyzing the force of the bolt—the spring element method. Second, the load-transfer model of the fully grouted bolt is established by using the spring element method, assuming that the bolt and the sidewall rock and soil are connected by tangential linear springs. The analytical solutions for the displacement, axial force, and shear-stress distribution of the bolt before and after the damage of the sidewall spring are given. It is found that the analysis results of the analytical model proposed in this paper have a great relationship with λ, which is the square root of the ratio of sidewall spring stiffness k′u to bolt stiffness ku. Further analysis found that this model is more suitable for the two working conditions of λ ≈ 0 and λ ≈ 1, and the relationship between sidewall spring stiffness k′u and pull-out stiffness K of the bolt was established under these two working conditions. Finally, the rationality and accuracy of the analytical model proposed in this study are verified by an analysis of two typical test cases under the two working conditions of λ ≈ 0 and λ ≈ 1.