Juan Lv
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Juan Lv has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Haiyan Chen
School of Environment and Resource, Southwest University of Science and Technology, Mianyang 621010, China
3 shared publications - Xue Li
School of Environment and Resource, Southwest University of Science and Technology, Mianyang 621010, China
2 shared publications - Huan Cheng
School of Environment and Resource, Southwest University of Science and Technology, Mianyang 621010, China
1 shared publication - Jianbo Wang
Key Laboratory of Solid Waste Treatment and Resource Recycle, Ministry of Education, and Sichuan Engineering Lab of Non-metallic Mineral Powder Modification and High-value Utilization, and School of Environment and Resource, Southwest University of Science and Technology, 59 Qinglong Road, Mianyang, Sichuan 621010, People’s Republic of China
1 shared publication - Longyuan Lin
School of Environment and Resource, Southwest University of Science and Technology, Mianyang 621010, China
1 shared publication - Shenglong Huang
School of Environment and Resource, Southwest University of Science and Technology, Mianyang 621010, China
1 shared publication
Latest Publications
- Open Access
- 22 April 2024
- Published by MDPI AG in Atmosphere
- Vol. 15 (4) , 510
The Synergistic Effect of the Filtration Area Controlled by the Electromagnetic Valve and Injection Pressure on Pulse-Jet Dust Cleaning Performance
In engineering pulse-jet dust collector applications, the filtration area and injection pressure are chosen mostly based on experience. The peak pressure is tested under different injection pressures and filtration areas controlled by an electromagnetic valve, and then comprehensively analyzes the effects of dust intensity, uniformity, and air consumption on dust cleaning to obtain a better filtration area controlled by an electromagnetic valve and injection pressure. The results show that considering the uniformity and intensity of dust cleaning, the filtration area of 33 m2 under the injection pressure of 0.4 MPa should be preferentially selected, with a standard deviation of 0.246 and a variance of 0.061. The filtration area of 27 m2 under the injection pressure of 0.3 MPa should be preferentially selected considering the unit air consumption, uniformity, and intensity of dust cleaning, the standard deviation of 0.252, and the variance of 0.064. The paper presents a theoretical foundation for selecting the optimal injection pressure and filter area regulated by an electromagnetic valve in pulse-jet dust collector systems.
- 22 April 2024
- Published by MDPI AG in Atmosphere
- Vol. 15 (4) , 510
Open AccessThe Synergistic Effect of the Filtration Area Controlled by the Electromagnetic Valve and Injection Pressure on Pulse-Jet Dust Cleaning Performance
In engineering pulse-jet dust collector applications, the filtration area and injection pressure are chosen mostly based on experience. The peak pressure is tested under different injection pressures and filtration areas controlled by an electromagnetic valve, and then comprehensively analyzes the effects of dust intensity, uniformity, and air consumption on dust cleaning to obtain a better filtration area controlled by an electromagnetic valve and injection pressure. The results show that considering the uniformity and intensity of dust cleaning, the filtration area of 33 m2 under the injection pressure of 0.4 MPa should be preferentially selected, with a standard deviation of 0.246 and a variance of 0.061. The filtration area of 27 m2 under the injection pressure of 0.3 MPa should be preferentially selected considering the unit air consumption, uniformity, and intensity of dust cleaning, the standard deviation of 0.252, and the variance of 0.064. The paper presents a theoretical foundation for selecting the optimal injection pressure and filter area regulated by an electromagnetic valve in pulse-jet dust collector systems.
- Open Access
- 6 February 2023
- Published by MDPI AG in Atmosphere
- Vol. 14 (2) , 325
Synergistic Effect Evaluation of Slot-Type Nozzle Area, Jet Pressure and Jet Distance on Improving Deashing Performance of Flat CARTRIDGE Filter
The difference of deashing performance between the areas of positive-to-blowing holes and that of non-positive-to-blowing holes is an important problem that causes a non-uniform deashing performance to a flat box filter cartridge, which limits the improvement of raising the ash cleaning efficiency to this kind of filter. In order to solve the above problems, the influence of blowing pressure, blowing distance and blowing hole area on cleaning performance was studied. Industrial coating test was also carried out to investigate and verify the actual ash cleaning performance under the optimal conditions obtained from the above investigations. Finally, the design method of the size of the slotted blowing hole was optimized. The results showed that at 0.3 MPa of the pulse pressure, the cleaning performance can meet the cleaning requirements and the best cleaning uniformity can be obtained. With the increase in slot-type nozzle area, the pressure at the areas facing the non-positive nozzles increased significantly, and thus the overall cleaning uniformity increased. The slot-type nozzle area of 273, 546 and 819 mm2 had the best cleaning effects at the jet distances of 40, 20~40 and 20 mm, respectively. The findings of this study are of great significance and can provide theoretical and experimental reference for important parameters selection of the flat cartridges filter in industrial application to improve the efficiency of dust removal.
- 6 February 2023
- Published by MDPI AG in Atmosphere
- Vol. 14 (2) , 325
Open AccessSynergistic Effect Evaluation of Slot-Type Nozzle Area, Jet Pressure and Jet Distance on Improving Deashing Performance of Flat CARTRIDGE Filter
The difference of deashing performance between the areas of positive-to-blowing holes and that of non-positive-to-blowing holes is an important problem that causes a non-uniform deashing performance to a flat box filter cartridge, which limits the improvement of raising the ash cleaning efficiency to this kind of filter. In order to solve the above problems, the influence of blowing pressure, blowing distance and blowing hole area on cleaning performance was studied. Industrial coating test was also carried out to investigate and verify the actual ash cleaning performance under the optimal conditions obtained from the above investigations. Finally, the design method of the size of the slotted blowing hole was optimized. The results showed that at 0.3 MPa of the pulse pressure, the cleaning performance can meet the cleaning requirements and the best cleaning uniformity can be obtained. With the increase in slot-type nozzle area, the pressure at the areas facing the non-positive nozzles increased significantly, and thus the overall cleaning uniformity increased. The slot-type nozzle area of 273, 546 and 819 mm2 had the best cleaning effects at the jet distances of 40, 20~40 and 20 mm, respectively. The findings of this study are of great significance and can provide theoretical and experimental reference for important parameters selection of the flat cartridges filter in industrial application to improve the efficiency of dust removal.
- Open Access
- 5 December 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (12) , 2040
An Efficient Ash Cleaning Method for Flat Box Cartridge Filter: Structure, Parameters and Cleaning Mechanism of Slotted Blowing
The problem of serious ash accumulation at the lower part of flat box filter cartridges is an important limitation for the improvement of ash cleaning efficiency in this kind of filter. To solve the above-mentioned problem, the type of slotted blowing hole impacting the performance of the ash removing under the same ash cleaning area was studied. In the present work, a total of four types of slotted blowing holes with different length were designed. The influence of blowing distance and blowing pressure on dust removal performance were investigated. Numerical simulation was conducted to demonstrate the mechanism of the dust removal process. An industrial coating test was also carried out to investigate and verify the actual ash cleaning performance under the optimal conditions as obtained from the above investigations. The results showed that: (1) the performance of dust cleaning produced by a three-slit blowhole was better than that by a four-slit blowhole; (2) 0.2 MPa was determined to be the optimal blowing pressure, which meets the requirement of ash cleaning; (3) 20 mm was selected as the optimal blowing distance, as this was the distance at which the surface side wall pressure at the non-positive-to-blow hole area was obviously increased, indicating that the whole performance of ash cleaning could be improved. The results obtained in this study are of great significance for improving the efficiency of dust removal in the use of flat box filters, promoting the development of dust removal technology, protection of environment, and reduction of human health damage.
- 5 December 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (12) , 2040
Open AccessAn Efficient Ash Cleaning Method for Flat Box Cartridge Filter: Structure, Parameters and Cleaning Mechanism of Slotted Blowing
The problem of serious ash accumulation at the lower part of flat box filter cartridges is an important limitation for the improvement of ash cleaning efficiency in this kind of filter. To solve the above-mentioned problem, the type of slotted blowing hole impacting the performance of the ash removing under the same ash cleaning area was studied. In the present work, a total of four types of slotted blowing holes with different length were designed. The influence of blowing distance and blowing pressure on dust removal performance were investigated. Numerical simulation was conducted to demonstrate the mechanism of the dust removal process. An industrial coating test was also carried out to investigate and verify the actual ash cleaning performance under the optimal conditions as obtained from the above investigations. The results showed that: (1) the performance of dust cleaning produced by a three-slit blowhole was better than that by a four-slit blowhole; (2) 0.2 MPa was determined to be the optimal blowing pressure, which meets the requirement of ash cleaning; (3) 20 mm was selected as the optimal blowing distance, as this was the distance at which the surface side wall pressure at the non-positive-to-blow hole area was obviously increased, indicating that the whole performance of ash cleaning could be improved. The results obtained in this study are of great significance for improving the efficiency of dust removal in the use of flat box filters, promoting the development of dust removal technology, protection of environment, and reduction of human health damage.