Senthil Selvan Subramanian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Senthil Selvan Subramanian has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Janaki Venkatesan
Department of Civil Engineering, College of Engineering and Technology SRM Institute of Science and Technology Kattankulathur Tamil Nadu India
6 shared publications - Anitha Krishnan
Department of Civil Engineering, SRM Institute of Science and Technology, Kattankulathur, India
2 shared publications - Florence More Dattu Shanker More
Department of Civil Engineering, SRM Institute of Science and Technology, Kattankulathur 603203, India
2 shared publications - Gopal Premkumar
Department of Civil Engineering, India
2 shared publications - V. Ganga
Department of Civil Engineering, Thiagarajar College of Engineering, Madurai, India
2 shared publications - Vijaya Bhoopathy
Department of Civil Engineering, Dr. M.G.R. Educational and Research Institute, Chennai, India
2 shared publications
Latest Publications
- 26 October 2026
- Published by Wiley in Structural Concrete
Axial compression behavior of hybrid fiber reinforced concrete encased cold‐formed steel composite columns: An experimental and theoretical investigation
Concrete encased steel composite columns conventionally comprise an encased steel section, reinforcement cage, and surrounding concrete. However, reinforcement congestion may create difficulties during concrete placement and compaction. This study examines the axial compression behavior of silica fume modified hybrid fiber reinforced concrete encased cold‐formed light gauge steel composite columns. Three concrete systems, namely conventional concrete (CC), steel–polypropylene hybrid fiber reinforced concrete (SP), and steel–coir hybrid fiber reinforced concrete (SC) incorporating sodium carbonate treated coir fibers, were considered. Channel, Z, and hat‐shaped cold‐formed steel sections with and without lip configurations were tested under concentric axial loading. Compared with CC specimens, SP and SC specimens exhibited increases in ultimate axial capacity of 11.8%–14.1% and 19.0%–23.0%, respectively. The incorporation of lip stiffeners increased axial capacity by 1.7%–3.2%, while the SC‐H‐L specimen achieved the highest load carrying capacity of 874.38 kN. A proposed ultimate load prediction model incorporating section geometry, lip configuration, and hybrid fiber interaction effects produced predicted‐to‐experimental capacity ratios ranging from 0.976 to 1.071. The results indicate that both hybrid fiber reinforcement and cold‐formed steel section configuration influenced the axial compression behavior of the composite columns.
- 26 October 2026
- Published by Wiley in Structural Concrete
Axial compression behavior of hybrid fiber reinforced concrete encased cold‐formed steel composite columns: An experimental and theoretical investigation
Concrete encased steel composite columns conventionally comprise an encased steel section, reinforcement cage, and surrounding concrete. However, reinforcement congestion may create difficulties during concrete placement and compaction. This study examines the axial compression behavior of silica fume modified hybrid fiber reinforced concrete encased cold‐formed light gauge steel composite columns. Three concrete systems, namely conventional concrete (CC), steel–polypropylene hybrid fiber reinforced concrete (SP), and steel–coir hybrid fiber reinforced concrete (SC) incorporating sodium carbonate treated coir fibers, were considered. Channel, Z, and hat‐shaped cold‐formed steel sections with and without lip configurations were tested under concentric axial loading. Compared with CC specimens, SP and SC specimens exhibited increases in ultimate axial capacity of 11.8%–14.1% and 19.0%–23.0%, respectively. The incorporation of lip stiffeners increased axial capacity by 1.7%–3.2%, while the SC‐H‐L specimen achieved the highest load carrying capacity of 874.38 kN. A proposed ultimate load prediction model incorporating section geometry, lip configuration, and hybrid fiber interaction effects produced predicted‐to‐experimental capacity ratios ranging from 0.976 to 1.071. The results indicate that both hybrid fiber reinforcement and cold‐formed steel section configuration influenced the axial compression behavior of the composite columns.
- Open Access
- 9 October 2026
- Published by MDPI AG in Construction Materials
- Vol. 6 (5) , 80
Fire Performance of Hybrid Fibre Reinforced Concrete with Steel and Sodium Carbonate-Treated Natural Fibres Under Standard Fire Exposure
This study investigates the fire behaviour of hybrid fibre reinforced concrete (HFRC) incorporating steel fibres combined with coir, polypropylene (PP), ramie, and sisal fibres under the ISO 834 standard fire curve. Concrete specimens were exposed to fire for 15, 30, and 60 min, and their residual compressive, split tensile, and flexural strengths were evaluated. Mass loss and a Thermal Performance Index (TPI) were determined to quantify fire-induced deterioration, while thermogravimetric analysis (TGA), X-ray diffraction (XRD), and scanning electron microscopy (SEM) were performed to characterize the thermal, phase, and microstructural changes after fire exposure. The results showed that all concrete mixtures experienced progressive reductions in mechanical properties with increasing fire exposure duration. After 60 min of fire exposure, the compressive strength reductions were 45.9%, 42.9%, 37.9%, 45.1%, and 43.8% for CC, SPP, SCO, SSI, and SRA, respectively. The SCO mixture retained 62.1% of its compressive strength, exhibited the lowest mass loss (8.2%), and achieved the highest Thermal Performance Index (7.57). The TGA, XRD, and SEM analyses indicated lower thermal and microstructural deterioration in the hybrid fibre reinforced mixtures than in the control concrete. The findings demonstrate that hybrid fibre reinforcement improves the residual performance of concrete subjected to standard fire exposure.
- 9 October 2026
- Published by MDPI AG in Construction Materials
- Vol. 6 (5) , 80
Open AccessFire Performance of Hybrid Fibre Reinforced Concrete with Steel and Sodium Carbonate-Treated Natural Fibres Under Standard Fire Exposure
This study investigates the fire behaviour of hybrid fibre reinforced concrete (HFRC) incorporating steel fibres combined with coir, polypropylene (PP), ramie, and sisal fibres under the ISO 834 standard fire curve. Concrete specimens were exposed to fire for 15, 30, and 60 min, and their residual compressive, split tensile, and flexural strengths were evaluated. Mass loss and a Thermal Performance Index (TPI) were determined to quantify fire-induced deterioration, while thermogravimetric analysis (TGA), X-ray diffraction (XRD), and scanning electron microscopy (SEM) were performed to characterize the thermal, phase, and microstructural changes after fire exposure. The results showed that all concrete mixtures experienced progressive reductions in mechanical properties with increasing fire exposure duration. After 60 min of fire exposure, the compressive strength reductions were 45.9%, 42.9%, 37.9%, 45.1%, and 43.8% for CC, SPP, SCO, SSI, and SRA, respectively. The SCO mixture retained 62.1% of its compressive strength, exhibited the lowest mass loss (8.2%), and achieved the highest Thermal Performance Index (7.57). The TGA, XRD, and SEM analyses indicated lower thermal and microstructural deterioration in the hybrid fibre reinforced mixtures than in the control concrete. The findings demonstrate that hybrid fibre reinforcement improves the residual performance of concrete subjected to standard fire exposure.
- Open Access
- 16 June 2026
- Published by Elsevier in Case Studies in Construction Materials
- Vol. 25
Influence of low-alkali surface modified natural fibres on the performance, microstructure and sustainability of hybrid fibre reinforced concrete
- 16 June 2026
- Published by Elsevier in Case Studies in Construction Materials
- Vol. 25
Open AccessInfluence of low-alkali surface modified natural fibres on the performance, microstructure and sustainability of hybrid fibre reinforced concrete
- Open Access
- 27 April 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Performance evaluation of light-gauge CFST columns incorporating expansive self-compacting concrete
This study conducts an extensive analysis of the axial compressive performance of rectangular light-gauge steel tube columns filled with expansive self-compacting concrete (ESCC). Thirty-six concrete-filled steel tube (CFST) samples, comprising conventional self-compacting concrete (SCC) and type K expansive cement-based SCC, as well as six hollow control samples, were subjected to monotonic axial loading tests. The experimental program included modifications in steel tube thickness (2 mm, 3 mm, and 4 mm), concrete grade (M30, M40, and M50), and column slenderness ratio to evaluate their impact on structural performance. The use of expansive agents successfully generated self-stress in the concrete core, hence improving the interaction among steel and concrete composites, as validated by strain measurements and analytical models. The ESCC-filled columns demonstrated enhanced confinement effects, delayed the initiation of local buckling,and significant improvements in load-bearing capability, resulting in strength increases of up to 21% compared with their SCC-filled equivalents. Finite element models created in ABAQUS precisely mirrored the experimental behaviour, with prediction discrepancies confined to a 10% margin. Additionally, a revised theoretical model adjusted to incorporate self-stress and confinement effects exhibited a robust association with the empirical results. The performance metrics, including strength enhancement, confinement efficiency, ductility, and concrete contribution, validate the efficiency of expansive self-compacting concrete in refining the structural integrity of CFST columns. The results highlight the promise of expansive self-compacting concrete as a pivotal material innovation for enhancing the reliability and load-bearing capacity of light-gauge steel–concrete composite columns.
- 27 April 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessPerformance evaluation of light-gauge CFST columns incorporating expansive self-compacting concrete
This study conducts an extensive analysis of the axial compressive performance of rectangular light-gauge steel tube columns filled with expansive self-compacting concrete (ESCC). Thirty-six concrete-filled steel tube (CFST) samples, comprising conventional self-compacting concrete (SCC) and type K expansive cement-based SCC, as well as six hollow control samples, were subjected to monotonic axial loading tests. The experimental program included modifications in steel tube thickness (2 mm, 3 mm, and 4 mm), concrete grade (M30, M40, and M50), and column slenderness ratio to evaluate their impact on structural performance. The use of expansive agents successfully generated self-stress in the concrete core, hence improving the interaction among steel and concrete composites, as validated by strain measurements and analytical models. The ESCC-filled columns demonstrated enhanced confinement effects, delayed the initiation of local buckling,and significant improvements in load-bearing capability, resulting in strength increases of up to 21% compared with their SCC-filled equivalents. Finite element models created in ABAQUS precisely mirrored the experimental behaviour, with prediction discrepancies confined to a 10% margin. Additionally, a revised theoretical model adjusted to incorporate self-stress and confinement effects exhibited a robust association with the empirical results. The performance metrics, including strength enhancement, confinement efficiency, ductility, and concrete contribution, validate the efficiency of expansive self-compacting concrete in refining the structural integrity of CFST columns. The results highlight the promise of expansive self-compacting concrete as a pivotal material innovation for enhancing the reliability and load-bearing capacity of light-gauge steel–concrete composite columns.
- Open Access
- 7 August 2025
- Published by Frontiers Media SA in Frontiers in Built Environment
- Vol. 11, 1610115
Prediction of mechanical properties of steel fibre-reinforced concrete under elevated temperature using artificial neural network techniques (ann)
This study investigates the mechanical performance of Steel Fibre-Reinforced Concrete (SFRC) subjected to elevated temperatures using artificial neural network (ANN) modeling. While existing literature mainly emphasizes the prediction of compressive strength, limited efforts have been made to predict other key mechanical properties under thermal stress. A comprehensive ANN framework was developed to simultaneously predict compressive strength, flexural strength, split tensile strength, and bond strength. The model was trained and validated using 967 experimental datasets encompassing a wide range of concrete mix designs and exposure conditions. The ANN architecture employed fully connected feedforward networks with ReLU activation in hidden layers and was individually optimized for each target parameter. The ANN model exhibited high predictive accuracy, with R² values of 0.85 (RMSE = 6.25 N/mm²) for compressive strength, 0.88 (RMSE = 5.74 N/mm²) for split tensile strength, 0.86 (RMSE = 6.18 N/mm²) for flexural strength, and 0.86 (RMSE = 6.08 N/mm²) for bond strength. These outcomes affirm the model's robustness in capturing complex nonlinear interactions between constituent materials, elevated temperature exposure, and mechanical behaviour. The proposed ANN-based framework provides an efficient and unified tool for predicting multiple mechanical properties of SFRC under thermal loading, requiring just 10 minutes for full analysis. This advancement fills a critical research gap and offers practical insights for the structural design of concrete in high-temperature environments.
- 7 August 2025
- Published by Frontiers Media SA in Frontiers in Built Environment
- Vol. 11, 1610115
Open AccessPrediction of mechanical properties of steel fibre-reinforced concrete under elevated temperature using artificial neural network techniques (ann)
This study investigates the mechanical performance of Steel Fibre-Reinforced Concrete (SFRC) subjected to elevated temperatures using artificial neural network (ANN) modeling. While existing literature mainly emphasizes the prediction of compressive strength, limited efforts have been made to predict other key mechanical properties under thermal stress. A comprehensive ANN framework was developed to simultaneously predict compressive strength, flexural strength, split tensile strength, and bond strength. The model was trained and validated using 967 experimental datasets encompassing a wide range of concrete mix designs and exposure conditions. The ANN architecture employed fully connected feedforward networks with ReLU activation in hidden layers and was individually optimized for each target parameter. The ANN model exhibited high predictive accuracy, with R² values of 0.85 (RMSE = 6.25 N/mm²) for compressive strength, 0.88 (RMSE = 5.74 N/mm²) for split tensile strength, 0.86 (RMSE = 6.18 N/mm²) for flexural strength, and 0.86 (RMSE = 6.08 N/mm²) for bond strength. These outcomes affirm the model's robustness in capturing complex nonlinear interactions between constituent materials, elevated temperature exposure, and mechanical behaviour. The proposed ANN-based framework provides an efficient and unified tool for predicting multiple mechanical properties of SFRC under thermal loading, requiring just 10 minutes for full analysis. This advancement fills a critical research gap and offers practical insights for the structural design of concrete in high-temperature environments.
- 14 April 2025
- Published by World Scientific Pub Co Pte Ltd in International Journal of Computational Methods
Investigation and Prediction of Buckling and Flexural Behavior in Perforated Staggered Cold-Formed Steel Beams
This paper investigates the prediction of buckling and flexural behavior in cold-formed steel (CFS) sections, specifically focusing on built-up SupaCee and lipped Cue (C) sections through experimental analysis. CFS beams with staggered slotted perforations are being used more often in light gauge steel construction to improve fire and energy performance. However, CFS beams’ load-bearing capability is compromised due to the lack of conclusive assessments in previous studies regarding design expressions for predicting the structural performance of slotted perforated CFS flexural elements. Parameters like the size of CFS beams, spacing between groups, rows of slots, and yield strength are crucial criteria. The study delves into the effects of dimensions of CFS beams, rows and row groupings of slots, staggered slotted perforations, and yield strength on the potential for local buckling of perforated staggered slotted CFS beams during bending. Additionally, a comprehensive nonlinear finite element modeling is conducted. The findings indicate that geometric parameters have nearly equal contributions to the flexural capacity and the specimens’ deflection.
- 14 April 2025
- Published by World Scientific Pub Co Pte Ltd in International Journal of Computational Methods
Investigation and Prediction of Buckling and Flexural Behavior in Perforated Staggered Cold-Formed Steel Beams
This paper investigates the prediction of buckling and flexural behavior in cold-formed steel (CFS) sections, specifically focusing on built-up SupaCee and lipped Cue (C) sections through experimental analysis. CFS beams with staggered slotted perforations are being used more often in light gauge steel construction to improve fire and energy performance. However, CFS beams’ load-bearing capability is compromised due to the lack of conclusive assessments in previous studies regarding design expressions for predicting the structural performance of slotted perforated CFS flexural elements. Parameters like the size of CFS beams, spacing between groups, rows of slots, and yield strength are crucial criteria. The study delves into the effects of dimensions of CFS beams, rows and row groupings of slots, staggered slotted perforations, and yield strength on the potential for local buckling of perforated staggered slotted CFS beams during bending. Additionally, a comprehensive nonlinear finite element modeling is conducted. The findings indicate that geometric parameters have nearly equal contributions to the flexural capacity and the specimens’ deflection.