Makrand A. Rakshe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Makrand A. Rakshe has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Abhijit Majumder
Department of Chemical Engineering, Indian Institute of Technology Bombay, India
1 shared publication Hari M Varma
Indian Institute of Technology Bombay
1 shared publicationKetaki Bachal
Department of Chemical Engineering, Indian Institute of Technology Bombay 1 , Mumbai, India
1 shared publication- Nixon M. Abraham
Department of Biology, Laboratory of Neural Circuits and Behaviour (LNCB) Indian Institute of Science Education and Research (IISER) Pune Maharashtra India
1 shared publication - Prasanna S. Gandhi
Suman Mashruwala Advanced Microengineering Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Bombay, Mumbai, India
1 shared publication - Pratik Tawade
Electronic Components Technology and Materials Department of Microelectronics Delft University of Technology Mekelweg 4 2628CD Delft Netherlands
1 shared publication
Latest Publications
- Open Access
Vascular tree structure-based perfusion phantom fabrication using modified Hele-Shaw Cell technique
Tissue phantoms that mimic microvasculature and perfusion are essential for modelling vascular function, guiding interventions, and calibrating imaging systems, which require faithful replication of vascular geometry and flow. Conventional fabrication strategies, including wire based molding, lithographic micromachining, and additive manufacturing, offer useful capabilities but remain constrained by predefined designs, rectangular channel cross sections, limited scalability, and high production costs. Reliance on predefined digital vascular models restricts design flexibility and limits the ability to capture the natural variability and complexity of real vascular systems. Here, we present a lithography-free, fractal-generating approach based on a modified Lifted Hele Shaw Cell (LHSC) technique, in which vascular networks emerge spontaneously via interfacial fluid instabilities. Unlike pre-designed methods, these structures are governed by fluid properties and flow conditions, enabling adaptive, physiologically relevant geometries with smooth Gaussian cross sections and natural diameter tapering. We demonstrate four phantom designs: a planar vascular tree, an anatomically guided cerebral network, a retinal vascular model, and a conformable curved substrate phantom. Validation using Laser Speckle Contrast Imaging confirms structural fidelity and physiologically relevant flow consistent with Murray law. This platform uniquely integrates realistic vascular architecture with emergent, fractal driven formation, highlighting its potential as a reproducible and biologically relevant alternative to conventional vascular phantom fabrication. Furthermore, the availability of such realistic in vitro vascular models can reduce reliance on animal experiments and contribute towards more ethical and sustainable preclinical research.
Open AccessVascular tree structure-based perfusion phantom fabrication using modified Hele-Shaw Cell technique
Tissue phantoms that mimic microvasculature and perfusion are essential for modelling vascular function, guiding interventions, and calibrating imaging systems, which require faithful replication of vascular geometry and flow. Conventional fabrication strategies, including wire based molding, lithographic micromachining, and additive manufacturing, offer useful capabilities but remain constrained by predefined designs, rectangular channel cross sections, limited scalability, and high production costs. Reliance on predefined digital vascular models restricts design flexibility and limits the ability to capture the natural variability and complexity of real vascular systems. Here, we present a lithography-free, fractal-generating approach based on a modified Lifted Hele Shaw Cell (LHSC) technique, in which vascular networks emerge spontaneously via interfacial fluid instabilities. Unlike pre-designed methods, these structures are governed by fluid properties and flow conditions, enabling adaptive, physiologically relevant geometries with smooth Gaussian cross sections and natural diameter tapering. We demonstrate four phantom designs: a planar vascular tree, an anatomically guided cerebral network, a retinal vascular model, and a conformable curved substrate phantom. Validation using Laser Speckle Contrast Imaging confirms structural fidelity and physiologically relevant flow consistent with Murray law. This platform uniquely integrates realistic vascular architecture with emergent, fractal driven formation, highlighting its potential as a reproducible and biologically relevant alternative to conventional vascular phantom fabrication. Furthermore, the availability of such realistic in vitro vascular models can reduce reliance on animal experiments and contribute towards more ethical and sustainable preclinical research.
- 1 December 2022
- Published by AIP Publishing in Biomicrofluidics
- Vol. 16 (6) , 064103
Scalable large-area mesh-structured microfluidic gradient generator for drug testing applications
Microfluidic concentration gradient generators are useful in drug testing, drug screening, and other cellular applications to avoid manual errors, save time, and labor. However, expensive fabrication techniques make such devices prohibitively costly. Here, in the present work, we developed a microfluidic concentration gradient generator (μCGG) using a recently proposed non-conventional photolithography-less method. In this method, ceramic suspension fluid was shaped into a square mesh by controlling Saffman Taylor instability in a multiport lifted Hele–Shaw cell (MLHSC). Using the shaped ceramic structure as the template, μCGG was prepared by soft lithography. The concentration gradient was characterized and effect of the flow rates was studied using COMSOL simulations. The simulation result was further validated by creating a fluorescein dye (fluorescein isothiocanate) gradient in the fabricated μCGG. To demonstrate the use of this device for drug testing, we created various concentrations of an anticancer drug—curcumin—using the device and determined its inhibitory concentration on cervical cancer cell-line HeLa. We found that the IC50 of curcumin for HeLa matched well with the conventional multi-well drug testing method. This method of μCGG fabrication has multiple advantages over conventional photolithography such as: (i) the channel layout and inlet-outlet arrangements can be changed by simply wiping the ceramic fluid before it solidifies, (ii) it is cost effective, (iii) large area patterning is easily achievable, and (iv) the method is scalable. This technique can be utilized to achieve a broad range of concentration gradient to be used for various biological and non-biological applications.
- 1 December 2022
- Published by AIP Publishing in Biomicrofluidics
- Vol. 16 (6) , 064103
Scalable large-area mesh-structured microfluidic gradient generator for drug testing applications
Microfluidic concentration gradient generators are useful in drug testing, drug screening, and other cellular applications to avoid manual errors, save time, and labor. However, expensive fabrication techniques make such devices prohibitively costly. Here, in the present work, we developed a microfluidic concentration gradient generator (μCGG) using a recently proposed non-conventional photolithography-less method. In this method, ceramic suspension fluid was shaped into a square mesh by controlling Saffman Taylor instability in a multiport lifted Hele–Shaw cell (MLHSC). Using the shaped ceramic structure as the template, μCGG was prepared by soft lithography. The concentration gradient was characterized and effect of the flow rates was studied using COMSOL simulations. The simulation result was further validated by creating a fluorescein dye (fluorescein isothiocanate) gradient in the fabricated μCGG. To demonstrate the use of this device for drug testing, we created various concentrations of an anticancer drug—curcumin—using the device and determined its inhibitory concentration on cervical cancer cell-line HeLa. We found that the IC50 of curcumin for HeLa matched well with the conventional multi-well drug testing method. This method of μCGG fabrication has multiple advantages over conventional photolithography such as: (i) the channel layout and inlet-outlet arrangements can be changed by simply wiping the ceramic fluid before it solidifies, (ii) it is cost effective, (iii) large area patterning is easily achievable, and (iv) the method is scalable. This technique can be utilized to achieve a broad range of concentration gradient to be used for various biological and non-biological applications.