Ștefan Răileanu
Research Subjects
Research Interests
Ștefan Răileanu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Amelia Maria Găman
Department of Pathophysiology, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania
1 shared publication - Andrei Biţă
Drug Research Center, Faculty of Pharmacy, University of Medicine and Pharmacy of Craiova, 2 Petru Rareş Street, 200349 Craiova, Romania
1 shared publication - Costel Valentin Manda
Faculty of Pharmacy, University of Medicine and Pharmacy of Craiova, 200638 Craiova, Romania
1 shared publication - Daniela Maria Calucică
Department of General and Inorganic Chemistry, Faculty of Pharmacy, University of Medicine and Pharmacy of Craiova, 2 Petru Rareș Street, 200349 Craiova, Romania
1 shared publication - Garofiţa Olivia Mateescu
Laboratory of Pathology, “Filantropia” Clinical Municipal Hospital, 200143 Craiova, Romania
1 shared publication - Liliana Stanca
Department of Forensic Medicine, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania
1 shared publication
Latest Publications
- Open Access
Development of a SPE-LC-MS Method for the Quantitation of Palbociclib and Abemaciclib in Human Plasma
Palbociclib and abemaciclib are two cyclin-dependent kinases 4 and 6 used for breast cancer treatment. Levels of these medicines present a significant interindividual variability, so monitoring those concentrations might be necessary in therapy. Most of the methods presented so far in the literature use simple protein precipitation of plasma proteins as sample preparation method followed by direct injection of the supernatant into the LC instrument, preceded or not by a simple filtration step. Within that approach, the probability of injecting proteins in the chromatographic system is increased. With the purpose of obtaining a cleaner extract of the drugs, we developed and validated a simple and accurate LC-MS method for determining palbociclib and abemaciclib in human plasma. Solid phase extraction (SPE) using Oasis PRiME HLB® cartridges was used for plasma sample preparation. The method provided clean extracts with a recovery extraction higher than 85% for both compounds. Separation was achieved by high-performance liquid chromatography (HPLC), using a C18 (4.6 × 50 mm) column, with a gradient elution of ammonium acetate/acetic acid-acetonitrile as the mobile phase. Detection was performed by mass spectrometry (MS) in single ion recording (SIR) mode. Intra-day and inter-day precision data for both analytes were 3.8–7.2% and 3.6–7.4%, respectively. Calibration curves were both linear between 2 and 400 ng/mL with a correlation coefficient higher than 0.998. The LC-MS method can be used to quantify the drugs in human plasma in routine analysis. The method proved to be useful in determining real plasma levels in patients involved in cancer therapy. Drug concentrations were determined in a 10 min run-time, including re-equilibration of the column.
Open AccessDevelopment of a SPE-LC-MS Method for the Quantitation of Palbociclib and Abemaciclib in Human Plasma
Palbociclib and abemaciclib are two cyclin-dependent kinases 4 and 6 used for breast cancer treatment. Levels of these medicines present a significant interindividual variability, so monitoring those concentrations might be necessary in therapy. Most of the methods presented so far in the literature use simple protein precipitation of plasma proteins as sample preparation method followed by direct injection of the supernatant into the LC instrument, preceded or not by a simple filtration step. Within that approach, the probability of injecting proteins in the chromatographic system is increased. With the purpose of obtaining a cleaner extract of the drugs, we developed and validated a simple and accurate LC-MS method for determining palbociclib and abemaciclib in human plasma. Solid phase extraction (SPE) using Oasis PRiME HLB® cartridges was used for plasma sample preparation. The method provided clean extracts with a recovery extraction higher than 85% for both compounds. Separation was achieved by high-performance liquid chromatography (HPLC), using a C18 (4.6 × 50 mm) column, with a gradient elution of ammonium acetate/acetic acid-acetonitrile as the mobile phase. Detection was performed by mass spectrometry (MS) in single ion recording (SIR) mode. Intra-day and inter-day precision data for both analytes were 3.8–7.2% and 3.6–7.4%, respectively. Calibration curves were both linear between 2 and 400 ng/mL with a correlation coefficient higher than 0.998. The LC-MS method can be used to quantify the drugs in human plasma in routine analysis. The method proved to be useful in determining real plasma levels in patients involved in cancer therapy. Drug concentrations were determined in a 10 min run-time, including re-equilibration of the column.