Hong Liang
Hong Liang has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
Yaling Ding
2 shared publications- Biao Han
Department of Thoracic Surgery, the First Hospital of Lanzhou University, Lanzhou, Gansu, China
1 shared publication - Bowen Chen
Department of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, Orthopedic Laboratory of Chongqing Medical University, Chongqing, China
1 shared publication - Chaojie Wang
Department of Cardiovascular Surgery, Guangdong Provincial Hospital of Chinese Medicine, the Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
1 shared publication Chunlei Song
Chengdu Rongsheng Pharmaceuticals Co. Ltd., 610041, Chengdu, China
1 shared publicationCongyan Shu
1 shared publication
Latest Publications
- 5 December 2022
- Published by Elsevier in Biochemical and Biophysical Research Communications
- Vol. 640, 80-87
Biological activity of a new recombinant human coagulation factor VIII and its efficacy in a small animal model
- 5 December 2022
- Published by Elsevier in Biochemical and Biophysical Research Communications
- Vol. 640, 80-87
Biological activity of a new recombinant human coagulation factor VIII and its efficacy in a small animal model
- Open Access
- 20 November 2022
- Published by Hindawi Limited in Journal of Cardiac Surgery
- Vol. 37 (12) , 5034-5040
Reconstruction of aortic sinus using patches in patients with acute type A aortic dissection
Acute type A aortic dissection involving the aortic sinus is often combined with varying degrees of aortic regurgitation, while the structure of the aortic valve is often undamaged. The aim of this study was to evaluate the clinical effects of reconstruction of the aortic sinus using patches in patients with acute type A aortic dissection. From January 2016 to December 2019, 52 patients with acute type A aortic dissection involving the aortic sinus were treated with aortic sinus reconstruction using pericardial or artificial vascular patches. The clinical and follow-up data were summarized. Bovine pericardial patches were used in 31 cases and artificial vascular patches were used in 21 cases for aortic sinus reconstruction. Cardiopulmonary bypass time was (250.4 ± 65.7) min, aortic cross clamp time was (143.7 ± 42.3) min, and hypothermic circulatory arrest time was (9.6 ± 8.1) min. Three patients died in hospital, with a mortality rate of 5.8%. Fifteen patients (28.8%) had mild postoperative aortic regurgitation. The follow-up duration was 40 ± 12 (range, 21-66) months. Five patients (10.2%) developed moderate to severe aortic regurgitation and 3 (6.1%) died during the follow-up period. The application of patches for aortic sinus reconstruction is a relatively easy method in aortic valve-sparing root reconstruction for acute type A aortic dissection involving the aortic sinus. The clinical and follow-up results are favorable.
- 20 November 2022
- Published by Hindawi Limited in Journal of Cardiac Surgery
- Vol. 37 (12) , 5034-5040
Open AccessReconstruction of aortic sinus using patches in patients with acute type A aortic dissection
Acute type A aortic dissection involving the aortic sinus is often combined with varying degrees of aortic regurgitation, while the structure of the aortic valve is often undamaged. The aim of this study was to evaluate the clinical effects of reconstruction of the aortic sinus using patches in patients with acute type A aortic dissection. From January 2016 to December 2019, 52 patients with acute type A aortic dissection involving the aortic sinus were treated with aortic sinus reconstruction using pericardial or artificial vascular patches. The clinical and follow-up data were summarized. Bovine pericardial patches were used in 31 cases and artificial vascular patches were used in 21 cases for aortic sinus reconstruction. Cardiopulmonary bypass time was (250.4 ± 65.7) min, aortic cross clamp time was (143.7 ± 42.3) min, and hypothermic circulatory arrest time was (9.6 ± 8.1) min. Three patients died in hospital, with a mortality rate of 5.8%. Fifteen patients (28.8%) had mild postoperative aortic regurgitation. The follow-up duration was 40 ± 12 (range, 21-66) months. Five patients (10.2%) developed moderate to severe aortic regurgitation and 3 (6.1%) died during the follow-up period. The application of patches for aortic sinus reconstruction is a relatively easy method in aortic valve-sparing root reconstruction for acute type A aortic dissection involving the aortic sinus. The clinical and follow-up results are favorable.
- Open Access
- 1 January 2017
- Published by China Engineering Science Press Co. Ltd. in Strategic Study of CAE
- Vol. 19 (2) , 55-61
Establishing an Innovation-Oriented National Preventive Medicine System in China
- 1 January 2017
- Published by China Engineering Science Press Co. Ltd. in Strategic Study of CAE
- Vol. 19 (2) , 55-61
Open AccessEstablishing an Innovation-Oriented National Preventive Medicine System in China