Richie Ranaisa Daru
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Richie Ranaisa Daru has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Ashfaq Adnan
Mechanical and Aerospace Engineering, University of Texas at Arlington, Arlington, USA
2 shared publications - Kamesh Subbarao
Department of Mechanical and Aerospace Engineering, The University of Texas at Arlington, Arlington, USA
1 shared publication Kristin Tighe
Mechanical and Aerospace Engineering, University of Texas at Arlington, Arlington, TX, USA
1 shared publication- Monjur Morshed Rabby
Department of Mechanical and Aerospace Engineering, University of Texas at Arlington, Arlington, TX 76019, USA
1 shared publication - Rassel Raihan
Department of Mechanical and Aerospace Engineering, University of Texas at Arlington, Arlington, TX 76019, USA
1 shared publication - Saina Namazifard
Department of Neuroscience, Baylor College of Medicine, Houston, TX 77030, USA
1 shared publication
Latest Publications
- Open Access
- 15 March 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (6) , 2495
Electrically Equivalent Head Tissue Materials for Electroencephalogram Study on Head Surrogates
With the recent advent of smart wearable sensors for monitoring brain activities in real-time, the scopes for using Electroencephalograms (EEGs) and Magnetoencephalography (MEG) in mobile and dynamic environments have become more relevant. However, their application in dynamic and open environments, typical of mobile wearable use, poses challenges. Presently, there is limited clinical data on using EEG/MEG as wearables. To advance these technologies at a time when large-scale clinical trials are not feasible, many researchers have turned to realistic phantom heads to further explore EEG and MEG capabilities. However, to achieve translational results, such phantom heads should have matching geometric features and electrical properties. Here, we have designed and fabricated multilayer chopped carbon fiber–PDMS reinforced composites to represent phantom head tissues. Two types of phantom layers are fabricated, namely seven-layer and four-layer systems with a goal to achieve matching electrical conductivities in each layer. Desired electrical conductivities are obtained by varying the weight fraction of the carbon fibers in PDMS. Then, the prototype system was calibrated and tested with a 32-electrode EEG cap. The test results demonstrated that the phantom effectively generates a variety of scalp potential patterns, achieved through a finite number of internal dipole generators within the phantom sample. This innovative design holds potential as a valuable test platform for assessing wearable EEG technology as well as developing an EEG analysis process.
- 15 March 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (6) , 2495
Open AccessElectrically Equivalent Head Tissue Materials for Electroencephalogram Study on Head Surrogates
With the recent advent of smart wearable sensors for monitoring brain activities in real-time, the scopes for using Electroencephalograms (EEGs) and Magnetoencephalography (MEG) in mobile and dynamic environments have become more relevant. However, their application in dynamic and open environments, typical of mobile wearable use, poses challenges. Presently, there is limited clinical data on using EEG/MEG as wearables. To advance these technologies at a time when large-scale clinical trials are not feasible, many researchers have turned to realistic phantom heads to further explore EEG and MEG capabilities. However, to achieve translational results, such phantom heads should have matching geometric features and electrical properties. Here, we have designed and fabricated multilayer chopped carbon fiber–PDMS reinforced composites to represent phantom head tissues. Two types of phantom layers are fabricated, namely seven-layer and four-layer systems with a goal to achieve matching electrical conductivities in each layer. Desired electrical conductivities are obtained by varying the weight fraction of the carbon fibers in PDMS. Then, the prototype system was calibrated and tested with a 32-electrode EEG cap. The test results demonstrated that the phantom effectively generates a variety of scalp potential patterns, achieved through a finite number of internal dipole generators within the phantom sample. This innovative design holds potential as a valuable test platform for assessing wearable EEG technology as well as developing an EEG analysis process.
- Open Access
- 21 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 124154-124166
Method for Identification of Multiple Low-Voltage Signal Sources Transmitted Through a Conductive Medium
Accurate detection of oscillatory electrical signals emitted from remote sources is necessary in many applications but poses several challenges. The major challenge is attributed to the source voltage and conductivity of the medium through which signals must transmit before they can be sensed by the receiving electrodes/sensors. This study introduces a novel algorithm to optimize source identification where low-voltage (mV range) signals transmit through a conductive medium. The proposed algorithm uses the measured data from different oscillatory signal sources and solves an inverse problem by minimizing a cost function to estimate all the signal properties, including the locations, frequencies, and phases. To increase the overall signal accuracy for a wide range of initial guess frequencies, we have utilized the Lomb-Scargle spectral analysis along with the Least Squares error optimization method. The data utilized in this study comes from an experimental setup that includes a bucket filled with salt-water as the conductive medium, multiple low-voltage signal sources and 32 remotely located sensors. The sources generate sine waves with amplitude of 10 mV and frequencies between 10 – 40 Hz. The average signal-to-noise ratio is approximately 10 dB. The algorithm has been validated using a single-source and multi-source setup. We observed that our algorithm can identify the source location within 10 mm from the actual source immersed inside the bucket of radius =~ 90 mm. Moreover, the frequency estimation error is nearly zero, which justifies the effectiveness of our proposed method.
- 21 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 124154-124166
Open AccessMethod for Identification of Multiple Low-Voltage Signal Sources Transmitted Through a Conductive Medium
Accurate detection of oscillatory electrical signals emitted from remote sources is necessary in many applications but poses several challenges. The major challenge is attributed to the source voltage and conductivity of the medium through which signals must transmit before they can be sensed by the receiving electrodes/sensors. This study introduces a novel algorithm to optimize source identification where low-voltage (mV range) signals transmit through a conductive medium. The proposed algorithm uses the measured data from different oscillatory signal sources and solves an inverse problem by minimizing a cost function to estimate all the signal properties, including the locations, frequencies, and phases. To increase the overall signal accuracy for a wide range of initial guess frequencies, we have utilized the Lomb-Scargle spectral analysis along with the Least Squares error optimization method. The data utilized in this study comes from an experimental setup that includes a bucket filled with salt-water as the conductive medium, multiple low-voltage signal sources and 32 remotely located sensors. The sources generate sine waves with amplitude of 10 mV and frequencies between 10 – 40 Hz. The average signal-to-noise ratio is approximately 10 dB. The algorithm has been validated using a single-source and multi-source setup. We observed that our algorithm can identify the source location within 10 mm from the actual source immersed inside the bucket of radius =~ 90 mm. Moreover, the frequency estimation error is nearly zero, which justifies the effectiveness of our proposed method.