Masoud Soroush Bathaei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Masoud Soroush Bathaei has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
Ahmed Hjazi
2 shared publicationsA. K. Kareem
Biomedical Engineering Department, College of Engineering and Technologies, Al-Mustaqbal University, Hillah, Iraq
1 shared publication- Abbas Firras Alamula
College of technical engineering, The Islamic university, Najaf, Iraq
1 shared publication - Abbas Firras Almuala
International NIMETOX Center, Sichuan Provincial Center for Mental Health, Sichuan Provincial People’s Hospital, School of Medicine, University of Electronic Science and Technology of China, Chengdu 610072, China
1 shared publication Abduladheem Turki Jalil
Medical Laboratories Techniques Department, Al-Mustaqbal University College, Babylon, Hilla, 51001, Iraq
1 shared publicationAbed J. Kadhim
Department of Medical Engineering, Al-Nisour University College, Baghdad, Iraq
1 shared publication
Latest Publications
- 7 December 2025
- Published by Springer Nature in Transactions of the Indian Institute of Metals
- Vol. 79 (1) , 2
Biodegradable Zinc-Based Alloys for Biomedical Implant Applications: A Review
- 7 December 2025
- Published by Springer Nature in Transactions of the Indian Institute of Metals
- Vol. 79 (1) , 2
Biodegradable Zinc-Based Alloys for Biomedical Implant Applications: A Review
- Open Access
- 8 December 2023
- Published by MDPI AG in Lubricants
- Vol. 11 (12) , 519
Unveiling the Effect of Particle Incorporation in PEO Coatings on the Corrosion and Wear Performance of Magnesium Implants
Magnesium has been a focal point of significant exploration in the biomedical engineering domain for many years due to its exceptional attributes, encompassing impressive specific strength, low density, excellent damping abilities, biodegradability, and the sought-after quality of biocompatibility. The primary drawback associated with magnesium-based implants is their susceptibility to corrosion and wear in physiological environments, which represents a significant limitation. Research findings have established that plasma electrolytic oxidation (PEO) induces substantial modifications in the surface characteristics and corrosion behavior of magnesium and its alloy counterparts. By subjecting the surface to high voltages, a porous ceramic coating is formed, resulting in not only altered surface properties and corrosion resistance, but also enhanced wear resistance. However, a drawback of the PEO process is that excessive pore formation and porosity within the shell could potentially undermine the coating’s corrosion and wear resistances. Altering the electrolyte conditions by introducing micro- and nano-particles can serve as a valuable approach to decrease coating porosity and enhance their ultimate characteristics. This paper evaluates the particle adhesion, composition, corrosion, and wear performances of particle-incorporated coatings applied to magnesium alloys through the PEO method.
- 8 December 2023
- Published by MDPI AG in Lubricants
- Vol. 11 (12) , 519
Open AccessUnveiling the Effect of Particle Incorporation in PEO Coatings on the Corrosion and Wear Performance of Magnesium Implants
Magnesium has been a focal point of significant exploration in the biomedical engineering domain for many years due to its exceptional attributes, encompassing impressive specific strength, low density, excellent damping abilities, biodegradability, and the sought-after quality of biocompatibility. The primary drawback associated with magnesium-based implants is their susceptibility to corrosion and wear in physiological environments, which represents a significant limitation. Research findings have established that plasma electrolytic oxidation (PEO) induces substantial modifications in the surface characteristics and corrosion behavior of magnesium and its alloy counterparts. By subjecting the surface to high voltages, a porous ceramic coating is formed, resulting in not only altered surface properties and corrosion resistance, but also enhanced wear resistance. However, a drawback of the PEO process is that excessive pore formation and porosity within the shell could potentially undermine the coating’s corrosion and wear resistances. Altering the electrolyte conditions by introducing micro- and nano-particles can serve as a valuable approach to decrease coating porosity and enhance their ultimate characteristics. This paper evaluates the particle adhesion, composition, corrosion, and wear performances of particle-incorporated coatings applied to magnesium alloys through the PEO method.
- 2 August 2023
- Published by Elsevier in Ceramics International
- Vol. 49 (21) , 33598-33606
Synthesis of TiO2/rGO composite coatings on titanium alloys with enhanced anticorrosion performance in palmitic acid-incorporated physiological solutions
- 2 August 2023
- Published by Elsevier in Ceramics International
- Vol. 49 (21) , 33598-33606
Synthesis of TiO2/rGO composite coatings on titanium alloys with enhanced anticorrosion performance in palmitic acid-incorporated physiological solutions
- Open Access
- 9 January 2023
- Published by MDPI AG in Pharmaceutics
- Vol. 15 (1) , 223
Recent Advancements in Metallic Drug-Eluting Implants
Over the past decade, metallic drug-eluting implants have gained significance in orthopedic and dental applications for controlled drug release, specifically for preventing infection associated with implants. Recent studies showed that metallic implants loaded with drugs were substituted for conventional bare metal implants to achieve sustained and controlled drug release, resulting in a desired local therapeutic concentration. A number of secondary features can be provided by the incorporated active molecules, including the promotion of osteoconduction and angiogenesis, the inhibition of bacterial invasion, and the modulation of host body reaction. This paper reviews recent trends in the development of the metallic drug-eluting implants with various drug delivery systems in the past three years. There are various types of drug-eluting implants that have been developed to meet this purpose, depending on the drug or agents that have been loaded on them. These include anti-inflammatory drugs, antibiotics agents, growth factors, and anti-resorptive drugs.
- 9 January 2023
- Published by MDPI AG in Pharmaceutics
- Vol. 15 (1) , 223
Open AccessRecent Advancements in Metallic Drug-Eluting Implants
Over the past decade, metallic drug-eluting implants have gained significance in orthopedic and dental applications for controlled drug release, specifically for preventing infection associated with implants. Recent studies showed that metallic implants loaded with drugs were substituted for conventional bare metal implants to achieve sustained and controlled drug release, resulting in a desired local therapeutic concentration. A number of secondary features can be provided by the incorporated active molecules, including the promotion of osteoconduction and angiogenesis, the inhibition of bacterial invasion, and the modulation of host body reaction. This paper reviews recent trends in the development of the metallic drug-eluting implants with various drug delivery systems in the past three years. There are various types of drug-eluting implants that have been developed to meet this purpose, depending on the drug or agents that have been loaded on them. These include anti-inflammatory drugs, antibiotics agents, growth factors, and anti-resorptive drugs.
- Open Access
- 10 December 2022
- Published by MDPI AG in Journal of Manufacturing and Materials Processing
- Vol. 6 (6) , 158
Laser-Based Additive Manufacturing of Magnesium Alloys for Bone Tissue Engineering Applications: From Chemistry to Clinic
Metallic biomedical implants are made from materials such as stainless steel, titanium, magnesium, and cobalt-based alloys. As a degradable biometal, magnesium (Mg) and its alloys are becoming more popular for applications in bone tissue engineering. Mg-based alloys have been found to be biocompatible, bioabsorbable, and bioactive, allowing them to be used as orthopedic implants with a low Young’s modulus. Computer-aided design can be used to design scaffolds with intricate porous structures based on patient-specific anatomical data. These models can be materialized rapidly and with reasonably acceptable dimensional accuracy by additive manufacturing (AM) techniques. It is known that lasers are the most widely investigated energy source for AM’ed Mg, as they offer some distinct advantages over other forms of energy. Recent studies have focused on developing biodegradable Mg scaffolds by using laser-based AM techniques. In this paper, we aim to review the recent progress of laser-based AM for Mg alloys and survey challenges in the research and future development of AM’ed Mg scaffolds for clinical applications.
- 10 December 2022
- Published by MDPI AG in Journal of Manufacturing and Materials Processing
- Vol. 6 (6) , 158
Open AccessLaser-Based Additive Manufacturing of Magnesium Alloys for Bone Tissue Engineering Applications: From Chemistry to Clinic
Metallic biomedical implants are made from materials such as stainless steel, titanium, magnesium, and cobalt-based alloys. As a degradable biometal, magnesium (Mg) and its alloys are becoming more popular for applications in bone tissue engineering. Mg-based alloys have been found to be biocompatible, bioabsorbable, and bioactive, allowing them to be used as orthopedic implants with a low Young’s modulus. Computer-aided design can be used to design scaffolds with intricate porous structures based on patient-specific anatomical data. These models can be materialized rapidly and with reasonably acceptable dimensional accuracy by additive manufacturing (AM) techniques. It is known that lasers are the most widely investigated energy source for AM’ed Mg, as they offer some distinct advantages over other forms of energy. Recent studies have focused on developing biodegradable Mg scaffolds by using laser-based AM techniques. In this paper, we aim to review the recent progress of laser-based AM for Mg alloys and survey challenges in the research and future development of AM’ed Mg scaffolds for clinical applications.
- Open Access
- 1 December 2022
- Published by IOP Publishing in Materials Research Express
- Vol. 9 (12) , 125401
Effect of PMMA sealing treatment on the corrosion behavior of plasma electrolytic oxidized titanium dental implants in fluoride-containing saliva solution
Titanium (Ti) and its alloys are widely used as dental implant materials because of their high mechanical properties, biocompatibility, and corrosion resistance. This research was undertaken to study the effect of polymethyl-methacrylate (PMMA) sealing layer on the corrosion performance of plasma electrolytic oxidation (PEO)-coated titanium-based dental implants in pure saliva and fluoride-containing saliva solutions. The phase structure, chemical composition, and microstructure of coatings were investigated via x-ray diffraction, Fourier transform infrared spectroscopy, and scanning electron microscopy, respectively. The corrosion behavior of the samples was evaluated by open circuit potential, potentiodynamic polarization, and electrochemical impedance spectroscopy tests. The deposition of the PMMA layer on the PEO-coated Ti dental implants was found to effectively seal the micropores and microcracks of the TiO2 coatings and block corrosive ions’ penetration routes through the coating. Thereby, the results indicated that better corrosion performance was observed when the PMMA layer is applied on PEO-coated Ti dental implants than on the simple PEO coatings.
- 1 December 2022
- Published by IOP Publishing in Materials Research Express
- Vol. 9 (12) , 125401
Open AccessEffect of PMMA sealing treatment on the corrosion behavior of plasma electrolytic oxidized titanium dental implants in fluoride-containing saliva solution
Titanium (Ti) and its alloys are widely used as dental implant materials because of their high mechanical properties, biocompatibility, and corrosion resistance. This research was undertaken to study the effect of polymethyl-methacrylate (PMMA) sealing layer on the corrosion performance of plasma electrolytic oxidation (PEO)-coated titanium-based dental implants in pure saliva and fluoride-containing saliva solutions. The phase structure, chemical composition, and microstructure of coatings were investigated via x-ray diffraction, Fourier transform infrared spectroscopy, and scanning electron microscopy, respectively. The corrosion behavior of the samples was evaluated by open circuit potential, potentiodynamic polarization, and electrochemical impedance spectroscopy tests. The deposition of the PMMA layer on the PEO-coated Ti dental implants was found to effectively seal the micropores and microcracks of the TiO2 coatings and block corrosive ions’ penetration routes through the coating. Thereby, the results indicated that better corrosion performance was observed when the PMMA layer is applied on PEO-coated Ti dental implants than on the simple PEO coatings.