Avinash Eranki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Avinash Eranki has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Inayathullah Ghori
Department of Cardiology, Kamineni Hospital, Department of Cardiology, Kamineni Hospital, Hyderabad, Telangana, Hyderabad, Telangana, India
3 shared publications - Renu John
Indian Institute of Technology Hyderabad
3 shared publications - Vidya Gopal T V
Indian Institute of Technology Hyderabad
3 shared publications - Ari Partanen
Profound Medical, Mississauga, Ontario, CANADA
2 shared publications - Bradford J. Wood
Center for Interventional Oncology, NCI, NIH, Bethesda, MD, USA
2 shared publications AeRang Kim
Sheikh Zayed Institute for Pediatric Surgical Innovation, Children's National Health System, Washington DC, United States of America
1 shared publication
Latest Publications
- 18 May 2025
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 24 (4) , 1279-1294
Effect of focused ultrasound on shearwave production in a hyperelastic media
Focused ultrasound (FUS) is an emerging noninvasive modality for treating various medical conditions. It encompasses both therapeutic and diagnostic applications, utilizing ultrasound waves at different intensities. In diagnostic modalities, ultrasound energy is deposited at the focus to generate acoustic radiation force (ARF), resulting in the generation of shear stress and waves, which are utilized in elastography to evaluate the mechanical properties of tissue. However, therapeutic modalities utilizing higher intensities may lead to elevated shear stress levels. The shear stress induced in the focal region during FUS procedures can potentially affect biological processes, such as cell membrane permeability and gene regulation. To better understand the mechanical stress generated during FUS procedures, we developed a finite element model (FEM) to simulate sonication using a single-element FUS transducer. We modeled soft tissue using a neo-Hookean hyperelastic constitutive behavior, offering a more realistic representation of tissue behavior compared to the linear elasticity assumptions commonly employed in ultrasound-based elastography techniques. Operational parameters were varied to simulate different acoustic powers of the transducer by applying mechanical surface pressure at various operating frequencies. The model depicted FUS wave propagation with amplified surface pressure at the focus, generating relevant focal pressures consistent with clinical setups. The focal beam size within the soft tissue material was characterized and exhibited dependency on the operating frequency of the transducer. As the FUS wave converged at the focus, an ARF was exerted, resulting in displacement and induced shear stress around the focal region, which were quantified. The displacement and shear stress that were analyzed were dependent on the applied transducer surface pressure. These findings deepen the understanding of the mechanics of low-intensity FUS and provide valuable insights into its shear-related effects due to displacement and deformation of the media.
- 18 May 2025
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 24 (4) , 1279-1294
Effect of focused ultrasound on shearwave production in a hyperelastic media
Focused ultrasound (FUS) is an emerging noninvasive modality for treating various medical conditions. It encompasses both therapeutic and diagnostic applications, utilizing ultrasound waves at different intensities. In diagnostic modalities, ultrasound energy is deposited at the focus to generate acoustic radiation force (ARF), resulting in the generation of shear stress and waves, which are utilized in elastography to evaluate the mechanical properties of tissue. However, therapeutic modalities utilizing higher intensities may lead to elevated shear stress levels. The shear stress induced in the focal region during FUS procedures can potentially affect biological processes, such as cell membrane permeability and gene regulation. To better understand the mechanical stress generated during FUS procedures, we developed a finite element model (FEM) to simulate sonication using a single-element FUS transducer. We modeled soft tissue using a neo-Hookean hyperelastic constitutive behavior, offering a more realistic representation of tissue behavior compared to the linear elasticity assumptions commonly employed in ultrasound-based elastography techniques. Operational parameters were varied to simulate different acoustic powers of the transducer by applying mechanical surface pressure at various operating frequencies. The model depicted FUS wave propagation with amplified surface pressure at the focus, generating relevant focal pressures consistent with clinical setups. The focal beam size within the soft tissue material was characterized and exhibited dependency on the operating frequency of the transducer. As the FUS wave converged at the focus, an ARF was exerted, resulting in displacement and induced shear stress around the focal region, which were quantified. The displacement and shear stress that were analyzed were dependent on the applied transducer surface pressure. These findings deepen the understanding of the mechanics of low-intensity FUS and provide valuable insights into its shear-related effects due to displacement and deformation of the media.
- Open Access
- 16 May 2025
- Published by Association for Computing Machinery (ACM)
- p. 10-15
Non-Invasive Detection of Cerebrovascular Diseases via Doppler Acoustic Signals and Machine Learning Approaches
- 16 May 2025
- Published by Association for Computing Machinery (ACM)
- p. 10-15
Open AccessNon-Invasive Detection of Cerebrovascular Diseases via Doppler Acoustic Signals and Machine Learning Approaches
- 2 March 2025
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 45 (2) , 198-210
Analysis of Doppler Audio Signals from the Carotid Artery
- 2 March 2025
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 45 (2) , 198-210
Analysis of Doppler Audio Signals from the Carotid Artery
- 4 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (23) , 39719-39726
Low-Cost Desktop Printed Sensors for Therapeutic Ultrasound Applications
High-intensity focused ultrasound (HIFU) is a non-invasive technology that uses acoustic waves to thermally ablate or mechanically disrupt solid tumors with high spatial precision. However, the focused ultrasound waves can cause a localized increase in temperature around the treated zone, often risking unsafe temperature elevation while treating tumors closer to the skin surface. Flexible sensors attached to the therapy transducer are a cost-effective approach to avoid skin burns and to get real-time feedback on changes in pressure and temperature during the HIFU treatment. Herein, we report low-cost inkjet-printed flexible sensors, integrated with the HIFU transducer to monitor pressure and temperature. The temperature sensors were fabricated as meandering structures using a desktop inkjet printer and nano-silver conductive ink on a polyethylene terephthalate (PET) flexible substrate designed for low-temperature applications. The temperature coefficient of resistance has been studied in the range of 30-70°C, showing linear characteristics with a mean sensitivity of ~0.03 Ω/°C. For the pressure/contact sensor, a carbon layer was printed over the silver interdigitated electrode layer, showing changes in resistance when deformed by uniaxial forces. Despite the defects in the printed films, the sensors showed a quick response (2-3 seconds) and recovery (5-6 seconds) times, with a mean sensitivity of about 24 N -1 , 16 N -1 , 8 N -1 for 1g, 2g and 5g weights, respectively. These sensors have significant potential to be quickly prototyped without relying on the traditional requirements of cleanroom and photolithography facilities for HIFU applications.
- 4 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (23) , 39719-39726
Low-Cost Desktop Printed Sensors for Therapeutic Ultrasound Applications
High-intensity focused ultrasound (HIFU) is a non-invasive technology that uses acoustic waves to thermally ablate or mechanically disrupt solid tumors with high spatial precision. However, the focused ultrasound waves can cause a localized increase in temperature around the treated zone, often risking unsafe temperature elevation while treating tumors closer to the skin surface. Flexible sensors attached to the therapy transducer are a cost-effective approach to avoid skin burns and to get real-time feedback on changes in pressure and temperature during the HIFU treatment. Herein, we report low-cost inkjet-printed flexible sensors, integrated with the HIFU transducer to monitor pressure and temperature. The temperature sensors were fabricated as meandering structures using a desktop inkjet printer and nano-silver conductive ink on a polyethylene terephthalate (PET) flexible substrate designed for low-temperature applications. The temperature coefficient of resistance has been studied in the range of 30-70°C, showing linear characteristics with a mean sensitivity of ~0.03 Ω/°C. For the pressure/contact sensor, a carbon layer was printed over the silver interdigitated electrode layer, showing changes in resistance when deformed by uniaxial forces. Despite the defects in the printed films, the sensors showed a quick response (2-3 seconds) and recovery (5-6 seconds) times, with a mean sensitivity of about 24 N -1 , 16 N -1 , 8 N -1 for 1g, 2g and 5g weights, respectively. These sensors have significant potential to be quickly prototyped without relying on the traditional requirements of cleanroom and photolithography facilities for HIFU applications.
- Open Access
- 13 September 2024
- Published by Association for Computing Machinery (ACM)
- p. 106-112
Haemodynamic Parameters Analysis through Audio Signal Processing Analysis of Doppler Audio Signals for Carotid Artery Assessment
Limitations of traditional auscultation for vascular assessment prompt the exploration of alternative methods. This study investigates the potential of Doppler ultrasound signal analysis as a non-invasive and potentially cost-effective tool for screening carotid artery health. We analyzed Doppler data from 216 individuals (18-59 years) and identified distinct frequency ranges associated with blood flow. Statistical analysis revealed significant correlations between these frequencies and hemodynamic parameters, suggesting a link to vascular health. These findings hold promise for developing a novel screening method for early detection of carotid artery stenosis.
- 13 September 2024
- Published by Association for Computing Machinery (ACM)
- p. 106-112
Open AccessHaemodynamic Parameters Analysis through Audio Signal Processing Analysis of Doppler Audio Signals for Carotid Artery Assessment
Limitations of traditional auscultation for vascular assessment prompt the exploration of alternative methods. This study investigates the potential of Doppler ultrasound signal analysis as a non-invasive and potentially cost-effective tool for screening carotid artery health. We analyzed Doppler data from 216 individuals (18-59 years) and identified distinct frequency ranges associated with blood flow. Statistical analysis revealed significant correlations between these frequencies and hemodynamic parameters, suggesting a link to vascular health. These findings hold promise for developing a novel screening method for early detection of carotid artery stenosis.
- Open Access
- 6 December 2022
- Published by Frontiers Media SA in Frontiers in Genetics
- Vol. 13, 1071352
Analysis of single-nucleotide polymorphisms in genes associated with triple-negative breast cancer
Triple-negative breast cancer (TNBC) is a rare variant of breast cancer (BC) known to be aggressive and refractory. TNBC lacks effective early diagnostic and therapeutic options leading to poorer outcomes. The genomic landscape and alterations leading to BC and TNBC are vast and unclear. Single nucleotide polymorphisms (SNPs) are a widespread form of genetic alterations with a multi-faceted impact on multiple diseases, including BC and TNBC. In this study, we attempted to construct a framework that could identify genes associated with TNBC and screen the SNPs reported in these genes using a set of computational predictors. This framework helped identifyBRCA1, BRCA2, EGFR, PIK3CA, PTEN,andTP53as recurrent genes associated with TNBC. We found 2%–29% of reported SNPs across genes to be typed pathogenic by all the predictors in the framework. We demonstrate that our framework prediction on BC samples identifies 99% of alterations as pathogenic by at least one predictor and 32% as pathogenic by all the predictors. Our framework could be an initial step in developing an early diagnosis of TNBC and potentially help improve the understanding of therapeutic resistance and sensitivity.
- 6 December 2022
- Published by Frontiers Media SA in Frontiers in Genetics
- Vol. 13, 1071352
Open AccessAnalysis of single-nucleotide polymorphisms in genes associated with triple-negative breast cancer
Triple-negative breast cancer (TNBC) is a rare variant of breast cancer (BC) known to be aggressive and refractory. TNBC lacks effective early diagnostic and therapeutic options leading to poorer outcomes. The genomic landscape and alterations leading to BC and TNBC are vast and unclear. Single nucleotide polymorphisms (SNPs) are a widespread form of genetic alterations with a multi-faceted impact on multiple diseases, including BC and TNBC. In this study, we attempted to construct a framework that could identify genes associated with TNBC and screen the SNPs reported in these genes using a set of computational predictors. This framework helped identifyBRCA1, BRCA2, EGFR, PIK3CA, PTEN,andTP53as recurrent genes associated with TNBC. We found 2%–29% of reported SNPs across genes to be typed pathogenic by all the predictors in the framework. We demonstrate that our framework prediction on BC samples identifies 99% of alterations as pathogenic by at least one predictor and 32% as pathogenic by all the predictors. Our framework could be an initial step in developing an early diagnosis of TNBC and potentially help improve the understanding of therapeutic resistance and sensitivity.
- Open Access
- 22 February 2018
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 34 (8) , 1213-1224
Mechanical fractionation of tissues using microsecond-long HIFU pulses on a clinical MR-HIFU system
Purpose: High intensity focussed ultrasound (HIFU) can non-invasively treat tumours with minimal or no damage to intervening tissues. While continuous-wave HIFU thermally ablates target tissue, the effect of hundreds of microsecond-long pulsed sonications is examined in this work. The objective of this study was to characterise sonication parameter-dependent thermomechanical bioeffects to provide the foundation for future preclinical studies and facilitate clinical translation. Methods and materials: Acoustic power, number of cycles/pulse, sonication time and pulse repetition frequency (PRF) were varied on a clinical magnetic resonance imaging (MRI)-guided HIFU (MR-HIFU) system. Ex vivo porcine liver, kidney and cardiac muscle tissue samples were sonicated (3 × 3 grid pattern, 1 mm spacing). Temperature, thermal dose and T2 relaxation times were quantified using MRI. Lesions were histologically analysed using H&E and vimentin stains for lesion structure and viability. Results: Thermomechanical HIFU bioeffects produced distinct types of fractionated tissue lesions: solid/thermal, paste-like and vacuolated. Sonications at 20 or 60 Hz PRF generated substantial tissue damage beyond the focal region, with reduced viability on vimentin staining, whereas H&E staining indicated intact tissue. Same sonication parameters produced dissimilar lesions in different tissue types, while significant differences in temperature, thermal dose and T2 were observed between the parameter sets. Conclusion: Clinical MR-HIFU system was utilised to generate distinct types of lesions and to produce targeted thermomechanical bioeffects in ex vivo tissues. The results guide HIFU research on thermomechanical tissue bioeffects, inform future studies and advice sonication parameter selection for direct tumour ablation or immunomodulation using a clinical MR-HIFU system.
- 22 February 2018
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 34 (8) , 1213-1224
Open AccessMechanical fractionation of tissues using microsecond-long HIFU pulses on a clinical MR-HIFU system
Purpose: High intensity focussed ultrasound (HIFU) can non-invasively treat tumours with minimal or no damage to intervening tissues. While continuous-wave HIFU thermally ablates target tissue, the effect of hundreds of microsecond-long pulsed sonications is examined in this work. The objective of this study was to characterise sonication parameter-dependent thermomechanical bioeffects to provide the foundation for future preclinical studies and facilitate clinical translation. Methods and materials: Acoustic power, number of cycles/pulse, sonication time and pulse repetition frequency (PRF) were varied on a clinical magnetic resonance imaging (MRI)-guided HIFU (MR-HIFU) system. Ex vivo porcine liver, kidney and cardiac muscle tissue samples were sonicated (3 × 3 grid pattern, 1 mm spacing). Temperature, thermal dose and T2 relaxation times were quantified using MRI. Lesions were histologically analysed using H&E and vimentin stains for lesion structure and viability. Results: Thermomechanical HIFU bioeffects produced distinct types of fractionated tissue lesions: solid/thermal, paste-like and vacuolated. Sonications at 20 or 60 Hz PRF generated substantial tissue damage beyond the focal region, with reduced viability on vimentin staining, whereas H&E staining indicated intact tissue. Same sonication parameters produced dissimilar lesions in different tissue types, while significant differences in temperature, thermal dose and T2 were observed between the parameter sets. Conclusion: Clinical MR-HIFU system was utilised to generate distinct types of lesions and to produce targeted thermomechanical bioeffects in ex vivo tissues. The results guide HIFU research on thermomechanical tissue bioeffects, inform future studies and advice sonication parameter selection for direct tumour ablation or immunomodulation using a clinical MR-HIFU system.
- Open Access
- 16 March 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (3) , e0173867
Boiling histotripsy lesion characterization on a clinical magnetic resonance imaging-guided high intensity focused ultrasound system
High intensity focused ultrasound (HIFU) is a non-invasive therapeutic technique that can thermally ablate tumors. Boiling histotripsy (BH) is a HIFU approach that can emulsify tissue in a few milliseconds. Lesion volume and temperature effects for different BH sonication parameters are currently not well characterized. In this work, lesion volume, temperature distribution, and area of lethal thermal dose were characterized for varying BH sonication parameters in tissue-mimicking phantoms (TMP) and demonstrated in ex vivo tissues. The following BH sonication parameters were varied using a clinical MR-HIFU system (Sonalleve V2, Philips, Vantaa, Finland): acoustic power, number of cycles/pulse, total sonication time, and pulse repetition frequency (PRF). A 3×3×3 pattern was sonicated inside TMP’s and ex vivo tissues. Post sonication, lesion volumes were quantified using 3D ultrasonography and temperature and thermal dose distributions were analyzed offline. Ex vivo tissues were sectioned and stained with H&E post sonication to assess tissue damage. Significant increase in lesion volume was observed while increasing the number of cycles/pulse and PRF. Other sonication parameters had no significant effect on lesion volume. Temperature full width at half maximum at the end of sonication increased significantly with all parameters except total sonication time. Positive correlation was also found between lethal thermal dose and lesion volume for all parameters except number of cycles/pulse. Gross pathology of ex vivo tissues post sonication displayed either completely or partially damaged tissue at the focal region. Surrounding tissues presented sharp boundaries, with little or no structural damage to adjacent critical structures such as bile duct and nerves. Our characterization of effects of HIFU sonication parameters on the resulting lesion demonstrates the ability to control lesion morphologic and thermal characteristics with a clinical MR-HIFU system in TMP’s and ex vivo tissues. We demonstrate that this system can produce spatially precise lesions in both phantoms and ex vivo tissues. The results provide guidance on a preliminary set of BH sonication parameters for this system, with a potential to facilitate BH translation to the clinic.
- 16 March 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (3) , e0173867
Open AccessBoiling histotripsy lesion characterization on a clinical magnetic resonance imaging-guided high intensity focused ultrasound system
High intensity focused ultrasound (HIFU) is a non-invasive therapeutic technique that can thermally ablate tumors. Boiling histotripsy (BH) is a HIFU approach that can emulsify tissue in a few milliseconds. Lesion volume and temperature effects for different BH sonication parameters are currently not well characterized. In this work, lesion volume, temperature distribution, and area of lethal thermal dose were characterized for varying BH sonication parameters in tissue-mimicking phantoms (TMP) and demonstrated in ex vivo tissues. The following BH sonication parameters were varied using a clinical MR-HIFU system (Sonalleve V2, Philips, Vantaa, Finland): acoustic power, number of cycles/pulse, total sonication time, and pulse repetition frequency (PRF). A 3×3×3 pattern was sonicated inside TMP’s and ex vivo tissues. Post sonication, lesion volumes were quantified using 3D ultrasonography and temperature and thermal dose distributions were analyzed offline. Ex vivo tissues were sectioned and stained with H&E post sonication to assess tissue damage. Significant increase in lesion volume was observed while increasing the number of cycles/pulse and PRF. Other sonication parameters had no significant effect on lesion volume. Temperature full width at half maximum at the end of sonication increased significantly with all parameters except total sonication time. Positive correlation was also found between lethal thermal dose and lesion volume for all parameters except number of cycles/pulse. Gross pathology of ex vivo tissues post sonication displayed either completely or partially damaged tissue at the focal region. Surrounding tissues presented sharp boundaries, with little or no structural damage to adjacent critical structures such as bile duct and nerves. Our characterization of effects of HIFU sonication parameters on the resulting lesion demonstrates the ability to control lesion morphologic and thermal characteristics with a clinical MR-HIFU system in TMP’s and ex vivo tissues. We demonstrate that this system can produce spatially precise lesions in both phantoms and ex vivo tissues. The results provide guidance on a preliminary set of BH sonication parameters for this system, with a potential to facilitate BH translation to the clinic.
- Open Access
- 1 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2009 (1094687X) , 2963-2966
Measurement of rectus femoris muscle velocities during patellar tendon jerk using vector tissue doppler imaging
We have developed a vector tissue Doppler imaging (TDI) system based on a clinical scanner that can be used to measure muscle velocities independent of the direction of motion. This method overcomes the limitations of conventional Doppler ultrasound, which can only measure velocity components along the ultrasound beam. In this study, we utilized this method to investigate the rectus femoris muscle velocities during a patellar tendon jerk test. Our goal was to investigate whether the muscle elongation velocities during a brisk tendon tap fall within the normal range of velocities that are expected due to rapid stretch of limb segments. In a preliminary study, we recruited six healthy volunteers (three men and three women) following informed consent. The stretch reflex response to tendon tap was evaluated by measuring: (1) the tapping force using an accelerometer instrumented to the neurological hammer (2) the angular velocities of the knee extension and flexion using a electrogoniometer (3) reflex activation using electromyography (EMG) and (4) muscle elongation, extension and flexion velocities using vector TDI. The passive joint angular velocity was linearly related to the passive muscle elongation velocity (R2=0.88). The maximum estimated joint angular velocity corresponding to muscle elongation due to tendon tap was less than 8.25 radians/s. This preliminary study demonstrates the feasibility of vector TDI for measuring longitudinal muscle velocities and indicates that the muscle elongation velocities during a clinical tendon tap test are within the normal range of values for rapid limb stretch encountered in daily life. With further refinement, vector TDI could become a powerful method for quantitative evaluation of muscle motion in musculoskeletal disorders.
- 1 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2009 (1094687X) , 2963-2966
Open AccessMeasurement of rectus femoris muscle velocities during patellar tendon jerk using vector tissue doppler imaging
We have developed a vector tissue Doppler imaging (TDI) system based on a clinical scanner that can be used to measure muscle velocities independent of the direction of motion. This method overcomes the limitations of conventional Doppler ultrasound, which can only measure velocity components along the ultrasound beam. In this study, we utilized this method to investigate the rectus femoris muscle velocities during a patellar tendon jerk test. Our goal was to investigate whether the muscle elongation velocities during a brisk tendon tap fall within the normal range of velocities that are expected due to rapid stretch of limb segments. In a preliminary study, we recruited six healthy volunteers (three men and three women) following informed consent. The stretch reflex response to tendon tap was evaluated by measuring: (1) the tapping force using an accelerometer instrumented to the neurological hammer (2) the angular velocities of the knee extension and flexion using a electrogoniometer (3) reflex activation using electromyography (EMG) and (4) muscle elongation, extension and flexion velocities using vector TDI. The passive joint angular velocity was linearly related to the passive muscle elongation velocity (R2=0.88). The maximum estimated joint angular velocity corresponding to muscle elongation due to tendon tap was less than 8.25 radians/s. This preliminary study demonstrates the feasibility of vector TDI for measuring longitudinal muscle velocities and indicates that the muscle elongation velocities during a clinical tendon tap test are within the normal range of values for rapid limb stretch encountered in daily life. With further refinement, vector TDI could become a powerful method for quantitative evaluation of muscle motion in musculoskeletal disorders.