Ruixin Luo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ruixin Luo has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Minpeng Xu
Tianjin University
5 shared publications Dong Ming
4 shared publications- Xiaolin Xiao
Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, China
4 shared publications - Dong Ming
Tianjin University
3 shared publications Yongzhi Huang
3 shared publications- Dian Li
Tianjin International Joint Research Center for Neural Engineering, Academy of Medical Engineering and Translational Medicine, Tianjin, People's Republic of China, Tianjin, 300072, CHINA
2 shared publications
Latest Publications
- 11 October 2025
- Published by Elsevier in Measurement
- Vol. 258
Active concentric ring electrode for high-resolution electrophysiological signal acquisition and analysis
- 11 October 2025
- Published by Elsevier in Measurement
- Vol. 258
Active concentric ring electrode for high-resolution electrophysiological signal acquisition and analysis
- 1 February 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (1) , 016043
Enhancing detection of SSVEPs using discriminant compacted network
Objective. Steady-state visual evoked potential-based brain–computer interfaces (SSVEP-BCIs) have gained significant attention due to their simplicity, high signal to noise ratio and high information transfer rates (ITRs). Currently, accurate detection is a critical issue for enhancing the performance of SSVEP-BCI systems. Approach. This study proposed a novel decoding method called Discriminant Compacted Network (Dis-ComNet), which exploited the advantages of both spatial filtering and deep learning (DL). Specifically, this study enhanced SSVEP features using global template alignment and discriminant spatial pattern, and then designed a compacted temporal-spatio module (CTSM) to extract finer features. The proposed method was evaluated on a self-collected high-frequency dataset, a public Benchmark dataset and a public wearable dataset. Main Results. The results showed that Dis-ComNet significantly outperformed state-of-the-art spatial filtering methods, DL methods, and other fusion methods. Remarkably, Dis-ComNet improved the classification accuracy by 3.9%, 3.5%, 3.2%, 13.3%, 17.4%, 37.5%, and 2.5% when comparing with eTRCA, eTRCA-R, TDCA, DNN, EEGnet, Ensemble-DNN, and TRCA-Net respectively in the high-frequency dataset. The achieved results were 4.7%, 4.6%, 23.6%, 52.5%, 31.7%, and 7.0% higher than those of eTRCA, eTRCA-R, DNN, EEGnet, Ensemble-DNN, and TRCA-Net, respectively, and were comparable to those of TDCA in Benchmark dataset. The accuracy of Dis-ComNet in the wearable dataset was 9.5%, 7.1%, 36.1%, 26.3%, 15.7% and 4.7% higher than eTRCA, eTRCA-R, DNN, EEGnet, Ensemble-DNN, and TRCA-Net respectively, and comparable to TDCA. Besides, our model achieved the ITRs up to 126.0 bits/min, 236.4 bits/min and 103.6 bits/min in the high-frequency, Benchmark and the wearable datasets respectively. Significance. This study develops an effective model for the detection of SSVEPs, facilitating the development of high accuracy SSVEP-BCI systems.
- 1 February 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (1) , 016043
Enhancing detection of SSVEPs using discriminant compacted network
Objective. Steady-state visual evoked potential-based brain–computer interfaces (SSVEP-BCIs) have gained significant attention due to their simplicity, high signal to noise ratio and high information transfer rates (ITRs). Currently, accurate detection is a critical issue for enhancing the performance of SSVEP-BCI systems. Approach. This study proposed a novel decoding method called Discriminant Compacted Network (Dis-ComNet), which exploited the advantages of both spatial filtering and deep learning (DL). Specifically, this study enhanced SSVEP features using global template alignment and discriminant spatial pattern, and then designed a compacted temporal-spatio module (CTSM) to extract finer features. The proposed method was evaluated on a self-collected high-frequency dataset, a public Benchmark dataset and a public wearable dataset. Main Results. The results showed that Dis-ComNet significantly outperformed state-of-the-art spatial filtering methods, DL methods, and other fusion methods. Remarkably, Dis-ComNet improved the classification accuracy by 3.9%, 3.5%, 3.2%, 13.3%, 17.4%, 37.5%, and 2.5% when comparing with eTRCA, eTRCA-R, TDCA, DNN, EEGnet, Ensemble-DNN, and TRCA-Net respectively in the high-frequency dataset. The achieved results were 4.7%, 4.6%, 23.6%, 52.5%, 31.7%, and 7.0% higher than those of eTRCA, eTRCA-R, DNN, EEGnet, Ensemble-DNN, and TRCA-Net, respectively, and were comparable to those of TDCA in Benchmark dataset. The accuracy of Dis-ComNet in the wearable dataset was 9.5%, 7.1%, 36.1%, 26.3%, 15.7% and 4.7% higher than eTRCA, eTRCA-R, DNN, EEGnet, Ensemble-DNN, and TRCA-Net respectively, and comparable to TDCA. Besides, our model achieved the ITRs up to 126.0 bits/min, 236.4 bits/min and 103.6 bits/min in the high-frequency, Benchmark and the wearable datasets respectively. Significance. This study develops an effective model for the detection of SSVEPs, facilitating the development of high accuracy SSVEP-BCI systems.
- Open Access
- 8 November 2024
- Published by Association for Computing Machinery (ACM)
- p. 120-124
An Investigation of the Spatial Properties of Steady-state Visual Evoked Potentials around the Ear
Objective: Electroencephalography (EEG) around the ear is promising for building practical steady-state visual evoked potential (SSVEP)-based brain-computer interfaces (BCIs). However, the SSVEPs collected around the ear exhibit weak features and low signal-to-noise ratio (SNR), posing challenges for practical applications. Currently, there is a lack of efficient encoding methods to enhance the discriminability of periauricular SSVEPs. Method: This study conducted a spatial-coding experiment for SSVEP-BCIs around the ear, which contained four single-flicker targets placed in four spatial directions, i.e., up, down, left, and right. The collected periauricular SSVEPs were analyzed in time, frequency, and spatial domains, and classified using task-related component analysis (TRCA). Results: The periauricular SSVEPs elicited by stimuli of different directions were varying in amplitude, phase, and spatial distribution. Besides, the binary classification accuracy of periauricular SSVEPs achieved up to 80.33% for the up and down stimuli, and 77.27% for the left and right stimuli. The quaternary classification accuracy of all four stimuli for single-subject was up to 86%. Conclusion: These results demonstrate the feasibility of spatial coding for SSVEP-BCIs around the ear. Significance: This study has potential applications in developing practical BCIs.
- 8 November 2024
- Published by Association for Computing Machinery (ACM)
- p. 120-124
Open AccessAn Investigation of the Spatial Properties of Steady-state Visual Evoked Potentials around the Ear
Objective: Electroencephalography (EEG) around the ear is promising for building practical steady-state visual evoked potential (SSVEP)-based brain-computer interfaces (BCIs). However, the SSVEPs collected around the ear exhibit weak features and low signal-to-noise ratio (SNR), posing challenges for practical applications. Currently, there is a lack of efficient encoding methods to enhance the discriminability of periauricular SSVEPs. Method: This study conducted a spatial-coding experiment for SSVEP-BCIs around the ear, which contained four single-flicker targets placed in four spatial directions, i.e., up, down, left, and right. The collected periauricular SSVEPs were analyzed in time, frequency, and spatial domains, and classified using task-related component analysis (TRCA). Results: The periauricular SSVEPs elicited by stimuli of different directions were varying in amplitude, phase, and spatial distribution. Besides, the binary classification accuracy of periauricular SSVEPs achieved up to 80.33% for the up and down stimuli, and 77.27% for the left and right stimuli. The quaternary classification accuracy of all four stimuli for single-subject was up to 86%. Conclusion: These results demonstrate the feasibility of spatial coding for SSVEP-BCIs around the ear. Significance: This study has potential applications in developing practical BCIs.
- Open Access
- 8 November 2024
- Published by Association for Computing Machinery (ACM)
- p. 97-103
EEG Signal Acquisition based on Laplacian Electrodes for Human SSVEP Research
Electroencephalography (EEG) is a technique that measures electrophysiological activity in the human brain, providing non-invasive monitoring with high temporal resolution. However, its spatial resolution is relatively low, presenting a significant challenge for improvement. Compared to traditional DISC electrodes, bipolar concentric ring electrodes (BCRE) can achieve surface Laplacian estimation. This study introduces BCRE made from sintered Ag/AgCl to investigate their effectiveness in detecting steady-state visually evoked potentials (SSVEP) for the first time. Long-term stability tests and noise analyses indicate that the sintered Ag/AgCl BCRE exhibits 64% less drift and about 29% lower noise than traditional gold BCRE. Additionally, this study successfully used BCRE to identify SSVEP signals at five frequencies: 14 Hz, 18 Hz, 22 Hz, and 26 Hz. This research lays the groundwork for enhancing EEG spatial resolution, promoting the use of Laplacian electrodes, and exploring new EEG features.
- 8 November 2024
- Published by Association for Computing Machinery (ACM)
- p. 97-103
Open AccessEEG Signal Acquisition based on Laplacian Electrodes for Human SSVEP Research
Electroencephalography (EEG) is a technique that measures electrophysiological activity in the human brain, providing non-invasive monitoring with high temporal resolution. However, its spatial resolution is relatively low, presenting a significant challenge for improvement. Compared to traditional DISC electrodes, bipolar concentric ring electrodes (BCRE) can achieve surface Laplacian estimation. This study introduces BCRE made from sintered Ag/AgCl to investigate their effectiveness in detecting steady-state visually evoked potentials (SSVEP) for the first time. Long-term stability tests and noise analyses indicate that the sintered Ag/AgCl BCRE exhibits 64% less drift and about 29% lower noise than traditional gold BCRE. Additionally, this study successfully used BCRE to identify SSVEP signals at five frequencies: 14 Hz, 18 Hz, 22 Hz, and 26 Hz. This research lays the groundwork for enhancing EEG spatial resolution, promoting the use of Laplacian electrodes, and exploring new EEG features.
- Open Access
- 4 December 2023
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 168, 107806
MetaBCI: An open-source platform for brain–computer interfaces
- 4 December 2023
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 168, 107806
Open AccessMetaBCI: An open-source platform for brain–computer interfaces
- 22 November 2023
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 20 (6) , 066013
Almost free of calibration for SSVEP-based brain-computer interfaces
Objective. Steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) is a promising technology that can achieve high information transfer rate (ITR) with supervised algorithms such as ensemble task-related component analysis (eTRCA) and task-discriminant component analysis (TDCA). However, training individual models requires a tedious and time-consuming calibration process, which hinders the real-life use of SSVEP-BCIs. A recent data augmentation method, called source aliasing matrix estimation (SAME), can generate new EEG samples from a few calibration trials. But SAME does not exploit the information across stimuli as well as only reduces the number of calibration trials per command, so it still has some limitations. Approach. This study proposes an extended version of SAME, called multi-stimulus SAME (msSAME), which exploits the similarity of the aliasing matrix across frequencies to enhance the performance of SSVEP-BCI with insufficient calibration trials. We also propose a semi-supervised approach based on msSAME that can further reduce the number of SSVEP frequencies needed for calibration. We evaluate our method on two public datasets, Benchmark and BETA, and an online experiment. Main results. The results show that msSAME outperforms SAME for both eTRCA and TDCA on the public datasets. Moreover, the semi-supervised msSAME-based method achieves comparable performance to the fully calibrated methods and outperforms the conventional free-calibrated methods. Remarkably, our method only needs 24 s to calibrate 40 targets in the online experiment and achieves an average ITR of 213.8 bits min−1 with a peak of 242.6 bits min−1. Significance. This study significantly reduces the calibration effort for individual SSVEP-BCIs, which is beneficial for developing practical plug-and-play SSVEP-BCIs.
- 22 November 2023
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 20 (6) , 066013
Almost free of calibration for SSVEP-based brain-computer interfaces
Objective. Steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) is a promising technology that can achieve high information transfer rate (ITR) with supervised algorithms such as ensemble task-related component analysis (eTRCA) and task-discriminant component analysis (TDCA). However, training individual models requires a tedious and time-consuming calibration process, which hinders the real-life use of SSVEP-BCIs. A recent data augmentation method, called source aliasing matrix estimation (SAME), can generate new EEG samples from a few calibration trials. But SAME does not exploit the information across stimuli as well as only reduces the number of calibration trials per command, so it still has some limitations. Approach. This study proposes an extended version of SAME, called multi-stimulus SAME (msSAME), which exploits the similarity of the aliasing matrix across frequencies to enhance the performance of SSVEP-BCI with insufficient calibration trials. We also propose a semi-supervised approach based on msSAME that can further reduce the number of SSVEP frequencies needed for calibration. We evaluate our method on two public datasets, Benchmark and BETA, and an online experiment. Main results. The results show that msSAME outperforms SAME for both eTRCA and TDCA on the public datasets. Moreover, the semi-supervised msSAME-based method achieves comparable performance to the fully calibrated methods and outperforms the conventional free-calibrated methods. Remarkably, our method only needs 24 s to calibrate 40 targets in the online experiment and achieves an average ITR of 213.8 bits min−1 with a peak of 242.6 bits min−1. Significance. This study significantly reduces the calibration effort for individual SSVEP-BCIs, which is beneficial for developing practical plug-and-play SSVEP-BCIs.
- 6 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (6) , 1775-1785
Data Augmentation of SSVEPs Using Source Aliasing Matrix Estimation for Brain–Computer Interfaces
Objective: Currently, ensemble task-related component analysis (eTRCA) and task discriminative component analysis (TDCA) are the state-of-the-art algorithms for steady-state visual evoked potential (SSVEP)-based brain-computer interfaces (BCIs). However, training the BCIs requires multiple calibration trials. With insufficient calibration data, the accuracy of the BCI will degrade, or even become invalid with only one calibration trial. However, collecting a large amount of electroencephalography (EEG) data for calibration is a time-consuming and laborious process, which hinders the practical use of eTRCA and TDCA. Methods: This study proposed a novel method, namely Source Aliasing Matrix Estimation (SAME), to augment the calibration data for SSVEP-BCIs. SAME could generate artificial EEG trials with the featured SSVEPs. Its effectiveness was evaluated using two public datasets (i.e., Benchmark, BETA). Results: When combined with SAME, both eTRCA and TDCA had significantly improved performance with a limited number of calibration data. Specifically, SAME increased the average accuracy of eTRCA and TDCA by about 12% and 3%, respectively, with as few as two calibration trials. Notably, SAME enabled eTRCA and TDCA to work well with a single calibration trial, achieving an average accuracy >90% for the Benchmark dataset and >70% for the BETA dataset with 1-second EEG. Conclusion: SAME is an effective method for SSVEP-BCIs to augment the calibration data, thereby significantly enhancing the performance of eTRCA and TDCA. Significance: We propose a new data-augmentation method that is compatible with the state-of-the-art algorithms of SSVEP-based BCIs. It can significantly reduce the efforts required to calibrate SSVEP-BCIs, which is promising for the development of practical BCIs.
- 6 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (6) , 1775-1785
Data Augmentation of SSVEPs Using Source Aliasing Matrix Estimation for Brain–Computer Interfaces
Objective: Currently, ensemble task-related component analysis (eTRCA) and task discriminative component analysis (TDCA) are the state-of-the-art algorithms for steady-state visual evoked potential (SSVEP)-based brain-computer interfaces (BCIs). However, training the BCIs requires multiple calibration trials. With insufficient calibration data, the accuracy of the BCI will degrade, or even become invalid with only one calibration trial. However, collecting a large amount of electroencephalography (EEG) data for calibration is a time-consuming and laborious process, which hinders the practical use of eTRCA and TDCA. Methods: This study proposed a novel method, namely Source Aliasing Matrix Estimation (SAME), to augment the calibration data for SSVEP-BCIs. SAME could generate artificial EEG trials with the featured SSVEPs. Its effectiveness was evaluated using two public datasets (i.e., Benchmark, BETA). Results: When combined with SAME, both eTRCA and TDCA had significantly improved performance with a limited number of calibration data. Specifically, SAME increased the average accuracy of eTRCA and TDCA by about 12% and 3%, respectively, with as few as two calibration trials. Notably, SAME enabled eTRCA and TDCA to work well with a single calibration trial, achieving an average accuracy >90% for the Benchmark dataset and >70% for the BETA dataset with 1-second EEG. Conclusion: SAME is an effective method for SSVEP-BCIs to augment the calibration data, thereby significantly enhancing the performance of eTRCA and TDCA. Significance: We propose a new data-augmentation method that is compatible with the state-of-the-art algorithms of SSVEP-based BCIs. It can significantly reduce the efforts required to calibrate SSVEP-BCIs, which is promising for the development of practical BCIs.