Ala’a Mhmoued Abdllh Alboull
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ala’a Mhmoued Abdllh Alboull has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Guobao Xu
University of Science and Technology of China
11 shared publications Zhiyong Dong
State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun, Jilin 130022, P. R. China
7 shared publicationsShiyu Xia
State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, China
4 shared publications- Altaf Hussain
State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, China
3 shared publications Hongzhan Liu
State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun, Jilin 130022, P R China
3 shared publicationsAbubakar Abdussalam
State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, Jilin, China
2 shared publications
Latest Publications
- 7 April 2026
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 18 (19) , 10397-10406
Engineered Co 3 O 4 nanoboxes boost luminol chemiluminescence for selective Mn 2+ sensing
Spinel oxide Co 3 O 4 nanoboxes boosted luminol/H 2 O 2 chemiluminescence by a factor of 670 and Mn 2+ significantly quenched chemiluminescence, enabling highly sensitive Mn 2+ detection.
- 7 April 2026
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 18 (19) , 10397-10406
Engineered Co 3 O 4 nanoboxes boost luminol chemiluminescence for selective Mn 2+ sensing
Spinel oxide Co 3 O 4 nanoboxes boosted luminol/H 2 O 2 chemiluminescence by a factor of 670 and Mn 2+ significantly quenched chemiluminescence, enabling highly sensitive Mn 2+ detection.
- 13 December 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (50) , 27544-27552
Electroanalysis Using Isostatic Graphite Electrodes
This study introduces isostatic graphite (ISG) as a novel electrode material for electroanalysis for the first time. Characterized by its homogeneous and isotropic structure with ultrahigh density and low cost, ISG was employed for the simultaneous electrochemical detection of dopamine (DA), ascorbic acid (AA), and uric acid (UA) using cyclic voltammetry (CV) and square wave voltammetry (SWV). The ISG electrode exhibited a linear relationship between the current response and concentration of these biomolecules. The limits of detection for individual DA, UA, and AA were 41, 44, and 19 nM, respectively. Real sample analysis, including human urine samples, DA injection, and AA injection, demonstrated good recovery and excellent reproducibility. It indicates that the ISG electrode is a promising alternative to an expensive electrode for electroanalytical applications.
- 13 December 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (50) , 27544-27552
Electroanalysis Using Isostatic Graphite Electrodes
This study introduces isostatic graphite (ISG) as a novel electrode material for electroanalysis for the first time. Characterized by its homogeneous and isotropic structure with ultrahigh density and low cost, ISG was employed for the simultaneous electrochemical detection of dopamine (DA), ascorbic acid (AA), and uric acid (UA) using cyclic voltammetry (CV) and square wave voltammetry (SWV). The ISG electrode exhibited a linear relationship between the current response and concentration of these biomolecules. The limits of detection for individual DA, UA, and AA were 41, 44, and 19 nM, respectively. Real sample analysis, including human urine samples, DA injection, and AA injection, demonstrated good recovery and excellent reproducibility. It indicates that the ISG electrode is a promising alternative to an expensive electrode for electroanalytical applications.
- 14 August 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (33) , 18159-18166
Tris(2,2′-bipyridyl)ruthenium(II) Electrochemiluminescence of Sugar Alcohols
Sugar alcohols are low-calorie sugar substitutes commonly used in sugar-free products. In this study, we report for the first time Ru(bpy)32+ electrochemiluminescence (ECL) of sugar alcohols. Ru(bpy)32+ ECL of sugar alcohols, including sorbitol, mannitol, isbitol (also called isomalt, isomaltitol, and palatinitol), maltitol, lactitol, xylitol, and erythritol, was investigated. The applicability of the Ru(bpy)32+ ECL system for sugar alcohol detection was demonstrated by using sorbitol as a representative analyte. The optimized system exhibited excellent analytical performance, with a wide linear detection range from 0.5 μM to 5 mM and a low detection limit of 0.026 μM (S/N = 3). In practical applications, the system demonstrated outstanding accuracy in detecting sorbitol in pharmaceutical samples, with recovery rates ranging from 97.75 to 104.00%. These findings establish the Ru(bpy)32+ ECL as an effective and sensitive method for the detection of sugar alcohols.
- 14 August 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (33) , 18159-18166
Tris(2,2′-bipyridyl)ruthenium(II) Electrochemiluminescence of Sugar Alcohols
Sugar alcohols are low-calorie sugar substitutes commonly used in sugar-free products. In this study, we report for the first time Ru(bpy)32+ electrochemiluminescence (ECL) of sugar alcohols. Ru(bpy)32+ ECL of sugar alcohols, including sorbitol, mannitol, isbitol (also called isomalt, isomaltitol, and palatinitol), maltitol, lactitol, xylitol, and erythritol, was investigated. The applicability of the Ru(bpy)32+ ECL system for sugar alcohol detection was demonstrated by using sorbitol as a representative analyte. The optimized system exhibited excellent analytical performance, with a wide linear detection range from 0.5 μM to 5 mM and a low detection limit of 0.026 μM (S/N = 3). In practical applications, the system demonstrated outstanding accuracy in detecting sorbitol in pharmaceutical samples, with recovery rates ranging from 97.75 to 104.00%. These findings establish the Ru(bpy)32+ ECL as an effective and sensitive method for the detection of sugar alcohols.
- 8 August 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1374, 344515
Rapid, selective, and sensitive electrochemical detection of artesunate via 4-aminophenylboronic acid oxidation accelerated by ethanol
- 8 August 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1374, 344515
Rapid, selective, and sensitive electrochemical detection of artesunate via 4-aminophenylboronic acid oxidation accelerated by ethanol
- 13 January 2025
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 41 (3) , 2065-2070
Electrochemical Detection of Hydrogen Peroxide at High Concentrations Using Hastelloy G35 Electrode
The detection of hydrogen peroxide (H2O2) at elevated concentrations while eliminating oxygen interference presents a significant challenge. Nickel-based stainless steel, such as Hastelloy G35, has shown excellent corrosion resistance. However, it has never been used in electroanalysis. In this study, the electrochemical analysis of H2O2 was conducted for the first time using nickel-based stainless steel electrode. The Hastelloy G35 electrode exhibited a very wide linear range from 1 up to 1000 mM and a detection limit of 0.0135 mM. The method is free from interference by oxygen. This method effectively detected H2O2 in skin wound wash solutions with excellent recoveries. The excellent performance of this method enhances its applicability in various fields, including industrial processes, environmental monitoring, and analytical chemistry, where quantifying concentrated H2O2 is of utmost importance. It shows that nickel-based stainless steel is promising for electroanalysis.
- 13 January 2025
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 41 (3) , 2065-2070
Electrochemical Detection of Hydrogen Peroxide at High Concentrations Using Hastelloy G35 Electrode
The detection of hydrogen peroxide (H2O2) at elevated concentrations while eliminating oxygen interference presents a significant challenge. Nickel-based stainless steel, such as Hastelloy G35, has shown excellent corrosion resistance. However, it has never been used in electroanalysis. In this study, the electrochemical analysis of H2O2 was conducted for the first time using nickel-based stainless steel electrode. The Hastelloy G35 electrode exhibited a very wide linear range from 1 up to 1000 mM and a detection limit of 0.0135 mM. The method is free from interference by oxygen. This method effectively detected H2O2 in skin wound wash solutions with excellent recoveries. The excellent performance of this method enhances its applicability in various fields, including industrial processes, environmental monitoring, and analytical chemistry, where quantifying concentrated H2O2 is of utmost importance. It shows that nickel-based stainless steel is promising for electroanalysis.
- 2 January 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 272, 117128
Single-electrode electrochemiluminescence immunosensor for multiplex detection of Aquaporin-4 antibody using metal-organic gels as coreactant
- 2 January 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 272, 117128
Single-electrode electrochemiluminescence immunosensor for multiplex detection of Aquaporin-4 antibody using metal-organic gels as coreactant
- 20 November 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (48) , 18927-18931
Single-Electrode Flow Cell for Electrochemiluminescent Flow Analysis
Flow injection analysis and liquid chromatography are frequently combined with electrochemiluminescence (ECL) for flow analysis. Almost all electrochemistry flow analyses employ traditional three-electrode electrochemical flow cells which have working electrode, counter electrode, and reference electrode; however, it is expensive and difficult to fabricate a traditional three-electrode electrochemical flow cell and inconvenient to renew the electrode. In this study, we have developed a single-electrode flow cell using commercially available conductive polyethylene film as the only electrode through potential differences induced by the electrode resistance for the first time. The single-electrode flow cell features a simple structure, easy renewal of the electrode, and low cost compared to the traditional three-electrode electrochemical flow cells. Taking the typical Ru(bpy)32+/oxalate ECL system as the analytical model, flow analysis of clinically important oxalate was achieved using single-electrode flow cell. A regression linear equation was obtained over the oxalate concentration ranges from 1 to 200 μM, with a detection limit of 0.92 μM. The single-electrode flow cell is promising for ECL flow analysis.
- 20 November 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (48) , 18927-18931
Single-Electrode Flow Cell for Electrochemiluminescent Flow Analysis
Flow injection analysis and liquid chromatography are frequently combined with electrochemiluminescence (ECL) for flow analysis. Almost all electrochemistry flow analyses employ traditional three-electrode electrochemical flow cells which have working electrode, counter electrode, and reference electrode; however, it is expensive and difficult to fabricate a traditional three-electrode electrochemical flow cell and inconvenient to renew the electrode. In this study, we have developed a single-electrode flow cell using commercially available conductive polyethylene film as the only electrode through potential differences induced by the electrode resistance for the first time. The single-electrode flow cell features a simple structure, easy renewal of the electrode, and low cost compared to the traditional three-electrode electrochemical flow cells. Taking the typical Ru(bpy)32+/oxalate ECL system as the analytical model, flow analysis of clinically important oxalate was achieved using single-electrode flow cell. A regression linear equation was obtained over the oxalate concentration ranges from 1 to 200 μM, with a detection limit of 0.92 μM. The single-electrode flow cell is promising for ECL flow analysis.
- 5 September 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (37) , 14741-14748
Signal-On Detection of Dopamine and Tyrosinase Using Tris(hydroxypropyl)phosphine as a New Lucigenin Chemiluminescence Coreactant
Dopamine (DA) is a very imperative neurotransmitter in our body, since it contributes to several physiological processes in our body, for example, memory, feeling, cognition, cardiovascular diseases, and hormone secretion. Meanwhile, tyrosinase is a critical biomarker for several dangerous skin diseases, including vitiligo and melanoma cancer. Most of the reported chemiluminescent (CL) methods for monitoring DA and tyrosinase are signal-off biosensors. Herein, we introduce a new chemiluminescent "signal-on" system, lucigenin-tris(hydroxypropyl)phosphine (THPP), for the selective determination of DA and tyrosinase. THPP is well known as a versatile and highly water-soluble sulfhydryl-reducing compound that is more highly stable against air oxidation than common disulfide reductants. By employing THPP for the first time as an efficient lucigenin coreactant, the lucigenin-THPP system has shown a high CL response (approximately 16-fold) compared to the lucigenin-H2O2 classical CL system. Surprisingly, DA can remarkably boost the CL intensity of the lucigenin-THPP CL system. Additionally, tyrosinase can efficiently catalyze the conversion of tyramine to DA. Therefore, lucigenin-THPP was employed as an ultrasensitive and selective signal-on CL system for the quantification of DA, tyrosinase, and THPP. The linear ranges for the quantification of DA, tyrosinase, and THPP were 50-1000 nM, 0.2-50 μg/mL, and 0.1-800 μM, respectively. LODs for DA and tyrosinase were estimated to be 24 nM and 0.18 μg/mL, respectively. Additionally, the CL system has been successfully employed for the detection of tyrosinase in human serum samples and the assay of DA in human serum samples as well as in dopamine injection ampules with excellent obtained recoveries.
- 5 September 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (37) , 14741-14748
Signal-On Detection of Dopamine and Tyrosinase Using Tris(hydroxypropyl)phosphine as a New Lucigenin Chemiluminescence Coreactant
Dopamine (DA) is a very imperative neurotransmitter in our body, since it contributes to several physiological processes in our body, for example, memory, feeling, cognition, cardiovascular diseases, and hormone secretion. Meanwhile, tyrosinase is a critical biomarker for several dangerous skin diseases, including vitiligo and melanoma cancer. Most of the reported chemiluminescent (CL) methods for monitoring DA and tyrosinase are signal-off biosensors. Herein, we introduce a new chemiluminescent "signal-on" system, lucigenin-tris(hydroxypropyl)phosphine (THPP), for the selective determination of DA and tyrosinase. THPP is well known as a versatile and highly water-soluble sulfhydryl-reducing compound that is more highly stable against air oxidation than common disulfide reductants. By employing THPP for the first time as an efficient lucigenin coreactant, the lucigenin-THPP system has shown a high CL response (approximately 16-fold) compared to the lucigenin-H2O2 classical CL system. Surprisingly, DA can remarkably boost the CL intensity of the lucigenin-THPP CL system. Additionally, tyrosinase can efficiently catalyze the conversion of tyramine to DA. Therefore, lucigenin-THPP was employed as an ultrasensitive and selective signal-on CL system for the quantification of DA, tyrosinase, and THPP. The linear ranges for the quantification of DA, tyrosinase, and THPP were 50-1000 nM, 0.2-50 μg/mL, and 0.1-800 μM, respectively. LODs for DA and tyrosinase were estimated to be 24 nM and 0.18 μg/mL, respectively. Additionally, the CL system has been successfully employed for the detection of tyrosinase in human serum samples and the assay of DA in human serum samples as well as in dopamine injection ampules with excellent obtained recoveries.
- 12 August 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (33) , 13504-13511
Metal–Organic Framework-Derived High-Entropy Oxides as Coreaction Accelerators for an Efficient Luminol/Dissolved Oxygen Electrochemiluminescence System for Ultrasensitive Mercury Detection
The development of luminol-dissolved O2 (luminol-DO) electrochemiluminescence (ECL) systems is crucial for real-world applications. Despite its stability and low biotoxicity, luminol-DO ECL systems struggle with low ECL performance due to their low reactivity. Investigating new materials like coreactant accelerators increases reactive oxygen species (ROS) formation and enhances luminol-DO ECL intensity. Motivated by the ROS-mediated ECL process, for the first time, we designed oxygen vacancy (OV)-rich high-entropy oxides (HEO) with five metal components [(FeCoNiCuZn)O] derived from metal-organic frameworks (MOFs) as coreaction accelerators to establish efficient luminol-DO ECL systems. High entropy (HE) MOFs were annealed at four different temperatures (600, 700, 800, and 900 °C). Indeed, the HE MOFs annealed at 800 °C (HEO-800) showed a 120-fold stronger ECL intensity compared to the bare glassy carbon electrode in the luminol-DO ECL system. The enhanced ECL performance can be attributed to the porous structure, unique morphology, heterostructures, high-density active sites, rich OV, unsaturated metals, and synergistic impact, which act as catalysts to accelerate the conversion of DO to ROS. The developed HEO-800-based luminol-DO ECL system can be effectively used for the high-sensitivity detection of mercury ions (Hg2+). The system detected Hg2+ over a wide concentration range from 0.1 nM to 100 μM, with a detection limit of 0.02 nM. The sensing mechanism relied on high-affinity metallophilic Hg2+-HEO-800 interactions, effectively quenching the ECL intensity of the luminol-DO/HEO-800 ECL system. The ECL sensing platform, developed without H2O2, offers a novel method for detecting substances, demonstrating significant potential for clinical diagnosis and biomarker analysis.
- 12 August 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (33) , 13504-13511
Metal–Organic Framework-Derived High-Entropy Oxides as Coreaction Accelerators for an Efficient Luminol/Dissolved Oxygen Electrochemiluminescence System for Ultrasensitive Mercury Detection
The development of luminol-dissolved O2 (luminol-DO) electrochemiluminescence (ECL) systems is crucial for real-world applications. Despite its stability and low biotoxicity, luminol-DO ECL systems struggle with low ECL performance due to their low reactivity. Investigating new materials like coreactant accelerators increases reactive oxygen species (ROS) formation and enhances luminol-DO ECL intensity. Motivated by the ROS-mediated ECL process, for the first time, we designed oxygen vacancy (OV)-rich high-entropy oxides (HEO) with five metal components [(FeCoNiCuZn)O] derived from metal-organic frameworks (MOFs) as coreaction accelerators to establish efficient luminol-DO ECL systems. High entropy (HE) MOFs were annealed at four different temperatures (600, 700, 800, and 900 °C). Indeed, the HE MOFs annealed at 800 °C (HEO-800) showed a 120-fold stronger ECL intensity compared to the bare glassy carbon electrode in the luminol-DO ECL system. The enhanced ECL performance can be attributed to the porous structure, unique morphology, heterostructures, high-density active sites, rich OV, unsaturated metals, and synergistic impact, which act as catalysts to accelerate the conversion of DO to ROS. The developed HEO-800-based luminol-DO ECL system can be effectively used for the high-sensitivity detection of mercury ions (Hg2+). The system detected Hg2+ over a wide concentration range from 0.1 nM to 100 μM, with a detection limit of 0.02 nM. The sensing mechanism relied on high-affinity metallophilic Hg2+-HEO-800 interactions, effectively quenching the ECL intensity of the luminol-DO/HEO-800 ECL system. The ECL sensing platform, developed without H2O2, offers a novel method for detecting substances, demonstrating significant potential for clinical diagnosis and biomarker analysis.
- 22 January 2024
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 7 (3) , 2983-2991
Bimetallic CoMoO4 Nanozymes Enhanced Luminol Chemiluminescence for the Detection of Dopamine
- 22 January 2024
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 7 (3) , 2983-2991
Bimetallic CoMoO4 Nanozymes Enhanced Luminol Chemiluminescence for the Detection of Dopamine