CRClaudia Katharina Renkamp

Claudia Katharina Renkamp

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Claudia Katharina Renkamp has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Intrafractional Motion in Online-Adaptive Magnetic Resonance-Guided Radiotherapy of Adrenal Metastases Leads to Reduced Target Volume Coverage and Elevated Organ-at-Risk Doses

    by Philipp Hoegen-Saßmannshausen, Tobias P. Hartschuh, Claudia Katharina Renkamp, Carolin Buchele, Fabian Schlüter, Elisabetta Sandrini, Fabian Weykamp, Sebastian Regnery, Eva Meixner, Laila König, et al.

    Background/Objectives: Stereotactic body radiotherapy is frequently used in patients with adrenal metastases. Motion of adherent radiosensitive organs at risk (OARs) and tumors influence OAR toxicity and tumor control. Online-adaptive Magnetic Resonance-guided radiotherapy (MRgRT) can address and mitigate interfractional changes. However, the impact of intrafractional variations in adrenal MRgRT is unknown. Methods: A total of 23 patients with 24 adrenal metastases were treated with MRgRT. After daily plan adaptation and before beam application, an additional (preRT) 3d MRI was acquired. PreRT target volumes and OARs were retrospectively recontoured in 200 fractions. The delivered, online-adapted treatment plans, as well as non-adapted baseline plans, were calculated on these re-contoured structures to quantify the dosimetric impact of intrafractional variations on target volume coverage and OAR doses with and without online adaptation. Normal tissue complication probabilities (NTCPs) were calculated. Results: The median time between the two MRIs was 56.4 min. GTV and PTV coverage (dose to 95% of the PTV, D95%, and volume covered by 100% of the prescription dose, V100%) were significantly inferior in the preRT plans. GTV Dmean was significantly impaired in left-sided metastases, but not in right-sided metastases. Compared to non-adapted preRT plans, adapted preRT plans were still significantly superior for all GTV and PTV metrics. Intrafractional violations of OAR constraints were frequent. D0.5cc and the volume exposed to the near-maximum dose constraint were significantly higher in the preRT plans. The volume exposed to the D0.5cc constraints in single fractions escalated up to 1.5 cc for the esophagus, 3.2 cc for the stomach, 5.3 cc for the duodenum and 7.3 cc for the bowel. This led to significantly elevated NTCPs for the stomach, bowel and duodenum. Neither PTV D95%, nor gastrointestinal OAR maximum doses were significantly impaired by longer fraction duration. Conclusions: Intrafractional motion in adrenal MRgRT caused significant impairment of target volume coverage (D95% and V100%), potentially undermining local control. Frequent violation of gastrointestinal OAR constraints led to elevated NTCP. Compared to non-adaptive treatment, online adaptation still highly improved GTV and PTV coverage.

  • Open Access

    Clinical Outcomes of Online Adaptive Magnetic Resonance-Guided Stereotactic Body Radiotherapy of Adrenal Metastases from a Single Institution

    by Philipp Hoegen-Saßmannshausen, Inga Jessen, Carolin Buchele, Fabian Schlüter, Carolin Rippke, Claudia Katharina Renkamp, Fabian Weykamp, Sebastian Regnery, Jakob Liermann, Eva Meixner, et al.

    (1) Background: Recent publications foster stereotactic body radiotherapy (SBRT) in patients with adrenal oligometastases or oligoprogression. However, local control (LC) after non-adaptive SBRT shows the potential for improvement. Online adaptive MR-guided SBRT (MRgSBRT) improves tumor coverage and organ-at-risk (OAR) sparing. Long-term results of adaptive MRgSBRT are still sparse. (2) Methods: Adaptive MRgSBRT was performed on a 0.35 T MR-Linac. LC, overall survival (OS), progression-free survival (PFS), overall response rate (ORR), and toxicity were assessed. (3) Results: 35 patients with 40 adrenal metastases were analyzed. The median gross tumor volume was 30.6 cc. The most common regimen was 10 fractions at 5 Gy. The median biologically effective dose (BED10) was 75.0 Gy. Plan adaptation was performed in 98% of all fractions. The median follow-up was 7.9 months. One local failure occurred after 16.6 months, resulting in estimated LC rates of 100% at one year and 90% at two years. ORR was 67.5%. The median OS was 22.4 months, and the median PFS was 5.1 months. No toxicity > CTCAE grade 2 occurred. (4) Conclusions: LC and ORR after adrenal adaptive MRgSBRT were excellent, even in a cohort with comparably large metastases. A BED10 of 75 Gy seems sufficient for improved LC in comparison to non-adaptive SBRT.


  • Open Access

    Evaluation of 2D ion chamber arrays for patient specific quality assurance using a static phantom at a 0.35 T MR-Linac

    by C. Katharina Renkamp, Daniela Eulenstein, Moritz Sebald, Fabian Schlüter, Carolin Buchele, Carolin Rippke, Jürgen P. Debus, Sebastian Klüter


  • Open Access

    Dosimetric Benefit of Adaptive Magnetic Resonance-Guided Stereotactic Body Radiotherapy of Liver Metastases

    by Fabian Weykamp, Efthimios Katsigiannopulos, Lars Piskorski, Sebastian Regnery, Philipp Hoegen, Jonas Ristau, C. Katharina Renkamp, Jakob Liermann, Tobias Forster, Kristin Lang, et al.

    (1) Background: To assess dosimetry benefits of stereotactic magnetic resonance (MR)-guided online adaptive radiotherapy (SMART) of liver metastases. (2) Methods: This is a subgroup analysis of an ongoing prospective registry including patients with liver metastases. Patients were treated at the MRIdian Linac between February 2020 and April 2022. The baseline plan was recalculated based on the updated anatomy of the day to generate the predicted plan. This predicted plan could then be re-optimized to create an adapted plan. (3) Results: Twenty-three patients received 30 SMART treatment series of in total 36 liver metastases. Most common primary tumors were colorectal- and pancreatic carcinoma (26.1% respectively). Most frequent fractionation scheme (46.6%) was 50 Gy in five fractions. The adapted plan was significantly superior compared to the predicted plan in regard to planning-target-volume (PTV) coverage, PTV overdosing, and organs-at-risk (OAR) dose constraints violations (91.5 vs. 38.0%, 6 vs. 19% and 0.6 vs. 10.0%; each p < 0.001). Plan adaptation significantly increased median BEDD95 by 3.2 Gy (p < 0.001). Mean total duration of SMART was 72.4 min. (4) Conclusions: SMART offers individualized ablative irradiation of liver metastases tailored to the daily anatomy with significant superior tumor coverage and improved sparing of OAR.


  • Open Access

    MR-guided adaptive versus ITV-based stereotactic body radiotherapy for hepatic metastases (MAESTRO): a randomized controlled phase II trial

    by P. Hoegen, K. S. Zhang, E. Tonndorf-Martini, F. Weykamp, S. Regnery, P. Naumann, K. Lang, J. Ristau, S. A. Körber, C. Dreher, et al.

    Background: Stereotactic body radiotherapy (SBRT) is an established local treatment method for patients with hepatic oligometastasis or oligoprogression. Liver metastases often occur in close proximity to radiosensitive organs at risk (OARs). This limits the possibility to apply sufficiently high doses needed for optimal local control. Online MR-guided radiotherapy (oMRgRT) is expected to hold potential to improve hepatic SBRT by offering superior soft-tissue contrast for enhanced target identification as well as the benefit of gating and daily real-time adaptive treatment. The MAESTRO trial therefore aims to assess the potential advantages of adaptive, gated MR-guided SBRT compared to conventional SBRT at a standard linac using an ITV (internal target volume) approach. Methods: This trial is conducted as a prospective, randomized, three-armed phase II study in 82 patients with hepatic metastases (solid malignant tumor, 1–3 hepatic metastases confirmed by magnetic resonance imaging (MRI), maximum diameter of each metastasis ≤ 5 cm (in case of 3 metastases: sum of diameters ≤ 12 cm), age ≥ 18 years, Karnofsky Performance Score ≥ 60%). If a biologically effective dose (BED) ≥ 100 Gy (α/β = 10 Gy) is feasible based on ITV-based planning, patients will be randomized to either MRgRT or ITV-based SBRT. If a lesion cannot be treated with a BED ≥ 100 Gy, the patient will be treated with MRgRT at the highest possible dose. Primary endpoint is the non-inferiority of MRgRT at the MRIdian Linac® system compared to ITV-based SBRT regarding hepatobiliary and gastrointestinal toxicity CTCAE III or higher. Secondary outcomes investigated are local, locoregional (intrahepatic) and distant tumor control, progression-free survival, overall survival, possible increase of BED using MRgRT if the BED is limited with ITV-based SBRT, treatment-related toxicity, quality of life, dosimetric parameters of radiotherapy plans as well as morphological and functional changes in MRI. Potential prognostic biomarkers will also be evaluated. Discussion: MRgRT is known to be both highly cost- and labor-intensive. The MAESTRO trial aims to provide randomized, higher-level evidence for the dosimetric and possible consecutive clinical benefit of MR-guided, on-table adaptive and gated SBRT for dose escalation in critically located hepatic metastases adjacent to radiosensitive OARs. Trial registration: The study has been prospectively registered on August 30th, 2021: Clinicaltrials.gov, “Magnetic Resonance-guided Adaptive Stereotactic Body Radiotherapy for Hepatic Metastases (MAESTRO)”, NCT05027711.