Paul Johns
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Paul Johns has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
- Gregory V. Hartland
University of Notre Dame
9 shared publications Braden Giordano
U.S. Naval Research Laboratory, 4555 Overlook Ave, SW, Washington, DC 20375, USA
6 shared publicationsCathy Scotto
U.S. Naval Research Laboratory, 4555 Overlook Ave, SW, Washington, DC 20375, USA
6 shared publicationsJay Eversole
Naval Research Laboratory Optical Sciences Division (Washington, United States of America)
6 shared publicationsKenneth Grabowski
U.S. Naval Research Laboratory, 4555 Overlook Ave, SW, Washington, DC 20375, USA
6 shared publications- Kuai Yu
State Key Laboratory of Radio Frequency Heterogeneous Integration College of Physics and Optoelectronic Engineering Shenzhen University Shenzhen China
6 shared publications
Latest Publications
- Open Access
- 21 July 2026
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 19 (14) , 4653-4667
Development and validation of an integrated Ambient Air Test Facility (AATF) for multi-instrument aerosol characterization
The U.S. Naval Research Laboratory has developed and validated an Ambient Air Test Facility (AATF) for controlled multi-instrument aerosol generation and characterization under realistic sampling conditions. The facility consists of a 14 m flow tube system that provides turbulent ( R e =40 000) outdoor ambient air flow at 2 m s −1 for testing aerosol detection and measurement systems in a controlled indoor environment. The AATF integrates 13 diagnostic instruments across four measurement categories: individual particle measurement, aerosol loading, aerosol composition, and flow characterization. Multiple aerosol generation systems enable dispersion of both liquid solutions or suspensions and dry powders, producing particle concentrations from 50 to 3000 µg m −3 and the ability to detect particles across a mean diameter range of 50 nm to 15 µm. Facility validation was conducted using multiple test chemicals including caffeine, oleic acid, phenanthrene, glycerol, tributyl phosphate, and Arizona test dust for three nominal concentration levels (low ∼ 100, medium ∼ 500, high >800 µg m −3 ). Aerosol concentration uniformity across the flow cross-section showed relative standard deviations below 3.5 %. Multi-instrument comparisons between redundant particle sizing systems (dual APS units, UHSAS, and Promo) demonstrated good measurement consistency, with gravimetric validation confirming total aerosol mass concentrations with a 20 % difference between the types of measurements. The Aerodyne Aerosol Mass Spectrometer correctly identified particle chemical signatures consistent with NIST fragmentation patterns for all test compounds. The facility employs shrouded probe sampling systems with isokinetic coupling to individual instruments to minimize particle losses and sampling biases across the particle size distribution. The AATF provides a repeatable and reliable aerosol generation testbed for detector development, evaluation, instrument inter-comparison, and aerosol measurement validation under controlled yet realistic ambient air conditions with controlled size distributions and total mass concentrations for a wide range of chemical aerosols.
- 21 July 2026
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 19 (14) , 4653-4667
Open AccessDevelopment and validation of an integrated Ambient Air Test Facility (AATF) for multi-instrument aerosol characterization
The U.S. Naval Research Laboratory has developed and validated an Ambient Air Test Facility (AATF) for controlled multi-instrument aerosol generation and characterization under realistic sampling conditions. The facility consists of a 14 m flow tube system that provides turbulent ( R e =40 000) outdoor ambient air flow at 2 m s −1 for testing aerosol detection and measurement systems in a controlled indoor environment. The AATF integrates 13 diagnostic instruments across four measurement categories: individual particle measurement, aerosol loading, aerosol composition, and flow characterization. Multiple aerosol generation systems enable dispersion of both liquid solutions or suspensions and dry powders, producing particle concentrations from 50 to 3000 µg m −3 and the ability to detect particles across a mean diameter range of 50 nm to 15 µm. Facility validation was conducted using multiple test chemicals including caffeine, oleic acid, phenanthrene, glycerol, tributyl phosphate, and Arizona test dust for three nominal concentration levels (low ∼ 100, medium ∼ 500, high >800 µg m −3 ). Aerosol concentration uniformity across the flow cross-section showed relative standard deviations below 3.5 %. Multi-instrument comparisons between redundant particle sizing systems (dual APS units, UHSAS, and Promo) demonstrated good measurement consistency, with gravimetric validation confirming total aerosol mass concentrations with a 20 % difference between the types of measurements. The Aerodyne Aerosol Mass Spectrometer correctly identified particle chemical signatures consistent with NIST fragmentation patterns for all test compounds. The facility employs shrouded probe sampling systems with isokinetic coupling to individual instruments to minimize particle losses and sampling biases across the particle size distribution. The AATF provides a repeatable and reliable aerosol generation testbed for detector development, evaluation, instrument inter-comparison, and aerosol measurement validation under controlled yet realistic ambient air conditions with controlled size distributions and total mass concentrations for a wide range of chemical aerosols.
- Open Access
- 10 June 2026
- Published by Copernicus GmbH
- Vol. 2026
Reply on RC2
The U.S. Naval Research Laboratory has developed and validated an Ambient Air Test Facility (AATF) for controlled multi-instrument aerosol generation and characterization under realistic sampling conditions. The facility consists of a 14 meter flow tube system that provides turbulent (Re = 40,000) outdoor ambient air flow at 2 m/s for testing aerosol detection and measurement systems in a controlled indoor environment. The AATF integrates 13 diagnostic instruments across four measurement categories: individual particle measurement, aerosol loading, aerosol composition, and flow characterization. Multiple aerosol generation systems enable dispersion of both liquid solutions or suspensions and dry powders, producing particle concentrations from 50 to 3,000 μg/m3 and the ability to detect particles across a mean diameter range of 50 nm to 20 μm. Facility validation was conducted using multiple test chemicals including caffeine, oleic acid, phenanthrene, glycerol, tributyl phosphate, and Arizona test dust for three nominal concentration levels (low ∼100, medium ∼500, high >800 μg/m3). Aerosol concentration uniformity across the flow cross-section showed relative standard deviations below 3.5%. Multi-instrument comparisons between redundant particle sizing systems (dual APS units, UHSAS, and Promo) demonstrated good measurement consistency, with gravimetric validation confirming total aerosol mass concentrations with a 20% difference between the types of measurements. The Aerodyne Aerosol Mass Spectrometer correctly identified particle chemical signatures consistent with NIST fragmentation patterns for all test compounds. The facility employs shrouded probe sampling systems with isokinetic coupling to individual instruments to minimize particle losses and sampling biases across the particle size distribution. The AATF provides a repeatable and reliable aerosol generation testbed for detector development, evaluation, instrument intercomparison, and aerosol measurement validation under controlled yet realistic ambient air conditions with controlled size distributions and total mass concentrations for a wide range of chemical aerosols.
- 10 June 2026
- Published by Copernicus GmbH
- Vol. 2026
Open AccessReply on RC2
The U.S. Naval Research Laboratory has developed and validated an Ambient Air Test Facility (AATF) for controlled multi-instrument aerosol generation and characterization under realistic sampling conditions. The facility consists of a 14 meter flow tube system that provides turbulent (Re = 40,000) outdoor ambient air flow at 2 m/s for testing aerosol detection and measurement systems in a controlled indoor environment. The AATF integrates 13 diagnostic instruments across four measurement categories: individual particle measurement, aerosol loading, aerosol composition, and flow characterization. Multiple aerosol generation systems enable dispersion of both liquid solutions or suspensions and dry powders, producing particle concentrations from 50 to 3,000 μg/m3 and the ability to detect particles across a mean diameter range of 50 nm to 20 μm. Facility validation was conducted using multiple test chemicals including caffeine, oleic acid, phenanthrene, glycerol, tributyl phosphate, and Arizona test dust for three nominal concentration levels (low ∼100, medium ∼500, high >800 μg/m3). Aerosol concentration uniformity across the flow cross-section showed relative standard deviations below 3.5%. Multi-instrument comparisons between redundant particle sizing systems (dual APS units, UHSAS, and Promo) demonstrated good measurement consistency, with gravimetric validation confirming total aerosol mass concentrations with a 20% difference between the types of measurements. The Aerodyne Aerosol Mass Spectrometer correctly identified particle chemical signatures consistent with NIST fragmentation patterns for all test compounds. The facility employs shrouded probe sampling systems with isokinetic coupling to individual instruments to minimize particle losses and sampling biases across the particle size distribution. The AATF provides a repeatable and reliable aerosol generation testbed for detector development, evaluation, instrument intercomparison, and aerosol measurement validation under controlled yet realistic ambient air conditions with controlled size distributions and total mass concentrations for a wide range of chemical aerosols.
- Open Access
- 6 June 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-23
Comment on egusphere-2025-6043
The U.S. Naval Research Laboratory has developed and validated an Ambient Air Test Facility (AATF) for controlled multi-instrument aerosol generation and characterization under realistic sampling conditions. The facility consists of a 14 meter flow tube system that provides turbulent (Re = 40,000) outdoor ambient air flow at 2 m/s for testing aerosol detection and measurement systems in a controlled indoor environment. The AATF integrates 13 diagnostic instruments across four measurement categories: individual particle measurement, aerosol loading, aerosol composition, and flow characterization. Multiple aerosol generation systems enable dispersion of both liquid solutions or suspensions and dry powders, producing particle concentrations from 50 to 3,000 μg/m3 and the ability to detect particles across a mean diameter range of 50 nm to 20 μm. Facility validation was conducted using multiple test chemicals including caffeine, oleic acid, phenanthrene, glycerol, tributyl phosphate, and Arizona test dust for three nominal concentration levels (low ∼100, medium ∼500, high >800 μg/m3). Aerosol concentration uniformity across the flow cross-section showed relative standard deviations below 3.5%. Multi-instrument comparisons between redundant particle sizing systems (dual APS units, UHSAS, and Promo) demonstrated good measurement consistency, with gravimetric validation confirming total aerosol mass concentrations with a 20% difference between the types of measurements. The Aerodyne Aerosol Mass Spectrometer correctly identified particle chemical signatures consistent with NIST fragmentation patterns for all test compounds. The facility employs shrouded probe sampling systems with isokinetic coupling to individual instruments to minimize particle losses and sampling biases across the particle size distribution. The AATF provides a repeatable and reliable aerosol generation testbed for detector development, evaluation, instrument intercomparison, and aerosol measurement validation under controlled yet realistic ambient air conditions with controlled size distributions and total mass concentrations for a wide range of chemical aerosols.
- 6 June 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-23
Open AccessComment on egusphere-2025-6043
The U.S. Naval Research Laboratory has developed and validated an Ambient Air Test Facility (AATF) for controlled multi-instrument aerosol generation and characterization under realistic sampling conditions. The facility consists of a 14 meter flow tube system that provides turbulent (Re = 40,000) outdoor ambient air flow at 2 m/s for testing aerosol detection and measurement systems in a controlled indoor environment. The AATF integrates 13 diagnostic instruments across four measurement categories: individual particle measurement, aerosol loading, aerosol composition, and flow characterization. Multiple aerosol generation systems enable dispersion of both liquid solutions or suspensions and dry powders, producing particle concentrations from 50 to 3,000 μg/m3 and the ability to detect particles across a mean diameter range of 50 nm to 20 μm. Facility validation was conducted using multiple test chemicals including caffeine, oleic acid, phenanthrene, glycerol, tributyl phosphate, and Arizona test dust for three nominal concentration levels (low ∼100, medium ∼500, high >800 μg/m3). Aerosol concentration uniformity across the flow cross-section showed relative standard deviations below 3.5%. Multi-instrument comparisons between redundant particle sizing systems (dual APS units, UHSAS, and Promo) demonstrated good measurement consistency, with gravimetric validation confirming total aerosol mass concentrations with a 20% difference between the types of measurements. The Aerodyne Aerosol Mass Spectrometer correctly identified particle chemical signatures consistent with NIST fragmentation patterns for all test compounds. The facility employs shrouded probe sampling systems with isokinetic coupling to individual instruments to minimize particle losses and sampling biases across the particle size distribution. The AATF provides a repeatable and reliable aerosol generation testbed for detector development, evaluation, instrument intercomparison, and aerosol measurement validation under controlled yet realistic ambient air conditions with controlled size distributions and total mass concentrations for a wide range of chemical aerosols.
- Open Access
- 9 February 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-23
Reply on RC1
The U.S. Naval Research Laboratory has developed and validated an Ambient Air Test Facility (AATF) for controlled multi-instrument aerosol generation and characterization under realistic sampling conditions. The facility consists of a 14 meter flow tube system that provides turbulent (Re = 40,000) outdoor ambient air flow at 2 m/s for testing aerosol detection and measurement systems in a controlled indoor environment. The AATF integrates 13 diagnostic instruments across four measurement categories: individual particle measurement, aerosol loading, aerosol composition, and flow characterization. Multiple aerosol generation systems enable dispersion of both liquid solutions or suspensions and dry powders, producing particle concentrations from 50 to 3,000 μg/m3 and the ability to detect particles across a mean diameter range of 50 nm to 20 μm. Facility validation was conducted using multiple test chemicals including caffeine, oleic acid, phenanthrene, glycerol, tributyl phosphate, and Arizona test dust for three nominal concentration levels (low ∼100, medium ∼500, high >800 μg/m3). Aerosol concentration uniformity across the flow cross-section showed relative standard deviations below 3.5%. Multi-instrument comparisons between redundant particle sizing systems (dual APS units, UHSAS, and Promo) demonstrated good measurement consistency, with gravimetric validation confirming total aerosol mass concentrations with a 20% difference between the types of measurements. The Aerodyne Aerosol Mass Spectrometer correctly identified particle chemical signatures consistent with NIST fragmentation patterns for all test compounds. The facility employs shrouded probe sampling systems with isokinetic coupling to individual instruments to minimize particle losses and sampling biases across the particle size distribution. The AATF provides a repeatable and reliable aerosol generation testbed for detector development, evaluation, instrument intercomparison, and aerosol measurement validation under controlled yet realistic ambient air conditions with controlled size distributions and total mass concentrations for a wide range of chemical aerosols.
- 9 February 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-23
Open AccessReply on RC1
The U.S. Naval Research Laboratory has developed and validated an Ambient Air Test Facility (AATF) for controlled multi-instrument aerosol generation and characterization under realistic sampling conditions. The facility consists of a 14 meter flow tube system that provides turbulent (Re = 40,000) outdoor ambient air flow at 2 m/s for testing aerosol detection and measurement systems in a controlled indoor environment. The AATF integrates 13 diagnostic instruments across four measurement categories: individual particle measurement, aerosol loading, aerosol composition, and flow characterization. Multiple aerosol generation systems enable dispersion of both liquid solutions or suspensions and dry powders, producing particle concentrations from 50 to 3,000 μg/m3 and the ability to detect particles across a mean diameter range of 50 nm to 20 μm. Facility validation was conducted using multiple test chemicals including caffeine, oleic acid, phenanthrene, glycerol, tributyl phosphate, and Arizona test dust for three nominal concentration levels (low ∼100, medium ∼500, high >800 μg/m3). Aerosol concentration uniformity across the flow cross-section showed relative standard deviations below 3.5%. Multi-instrument comparisons between redundant particle sizing systems (dual APS units, UHSAS, and Promo) demonstrated good measurement consistency, with gravimetric validation confirming total aerosol mass concentrations with a 20% difference between the types of measurements. The Aerodyne Aerosol Mass Spectrometer correctly identified particle chemical signatures consistent with NIST fragmentation patterns for all test compounds. The facility employs shrouded probe sampling systems with isokinetic coupling to individual instruments to minimize particle losses and sampling biases across the particle size distribution. The AATF provides a repeatable and reliable aerosol generation testbed for detector development, evaluation, instrument intercomparison, and aerosol measurement validation under controlled yet realistic ambient air conditions with controlled size distributions and total mass concentrations for a wide range of chemical aerosols.
- Open Access
- 30 January 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-23
Comment on egusphere-2025-6043
The U.S. Naval Research Laboratory has developed and validated an Ambient Air Test Facility (AATF) for controlled multi-instrument aerosol generation and characterization under realistic sampling conditions. The facility consists of a 14 meter flow tube system that provides turbulent (Re = 40,000) outdoor ambient air flow at 2 m/s for testing aerosol detection and measurement systems in a controlled indoor environment. The AATF integrates 13 diagnostic instruments across four measurement categories: individual particle measurement, aerosol loading, aerosol composition, and flow characterization. Multiple aerosol generation systems enable dispersion of both liquid solutions or suspensions and dry powders, producing particle concentrations from 50 to 3,000 μg/m3 and the ability to detect particles across a mean diameter range of 50 nm to 20 μm. Facility validation was conducted using multiple test chemicals including caffeine, oleic acid, phenanthrene, glycerol, tributyl phosphate, and Arizona test dust for three nominal concentration levels (low ∼100, medium ∼500, high >800 μg/m3). Aerosol concentration uniformity across the flow cross-section showed relative standard deviations below 3.5%. Multi-instrument comparisons between redundant particle sizing systems (dual APS units, UHSAS, and Promo) demonstrated good measurement consistency, with gravimetric validation confirming total aerosol mass concentrations with a 20% difference between the types of measurements. The Aerodyne Aerosol Mass Spectrometer correctly identified particle chemical signatures consistent with NIST fragmentation patterns for all test compounds. The facility employs shrouded probe sampling systems with isokinetic coupling to individual instruments to minimize particle losses and sampling biases across the particle size distribution. The AATF provides a repeatable and reliable aerosol generation testbed for detector development, evaluation, instrument intercomparison, and aerosol measurement validation under controlled yet realistic ambient air conditions with controlled size distributions and total mass concentrations for a wide range of chemical aerosols.
- 30 January 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-23
Open AccessComment on egusphere-2025-6043
The U.S. Naval Research Laboratory has developed and validated an Ambient Air Test Facility (AATF) for controlled multi-instrument aerosol generation and characterization under realistic sampling conditions. The facility consists of a 14 meter flow tube system that provides turbulent (Re = 40,000) outdoor ambient air flow at 2 m/s for testing aerosol detection and measurement systems in a controlled indoor environment. The AATF integrates 13 diagnostic instruments across four measurement categories: individual particle measurement, aerosol loading, aerosol composition, and flow characterization. Multiple aerosol generation systems enable dispersion of both liquid solutions or suspensions and dry powders, producing particle concentrations from 50 to 3,000 μg/m3 and the ability to detect particles across a mean diameter range of 50 nm to 20 μm. Facility validation was conducted using multiple test chemicals including caffeine, oleic acid, phenanthrene, glycerol, tributyl phosphate, and Arizona test dust for three nominal concentration levels (low ∼100, medium ∼500, high >800 μg/m3). Aerosol concentration uniformity across the flow cross-section showed relative standard deviations below 3.5%. Multi-instrument comparisons between redundant particle sizing systems (dual APS units, UHSAS, and Promo) demonstrated good measurement consistency, with gravimetric validation confirming total aerosol mass concentrations with a 20% difference between the types of measurements. The Aerodyne Aerosol Mass Spectrometer correctly identified particle chemical signatures consistent with NIST fragmentation patterns for all test compounds. The facility employs shrouded probe sampling systems with isokinetic coupling to individual instruments to minimize particle losses and sampling biases across the particle size distribution. The AATF provides a repeatable and reliable aerosol generation testbed for detector development, evaluation, instrument intercomparison, and aerosol measurement validation under controlled yet realistic ambient air conditions with controlled size distributions and total mass concentrations for a wide range of chemical aerosols.
- Open Access
- 11 January 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-23
Development and Validation of an Integrated Ambient Air Test Facility (AATF) for Multi-Instrument Aerosol Characterization
The U.S. Naval Research Laboratory has developed and validated an Ambient Air Test Facility (AATF) for controlled multi-instrument aerosol generation and characterization under realistic sampling conditions. The facility consists of a 14 meter flow tube system that provides turbulent (Re = 40,000) outdoor ambient air flow at 2 m/s for testing aerosol detection and measurement systems in a controlled indoor environment. The AATF integrates 13 diagnostic instruments across four measurement categories: individual particle measurement, aerosol loading, aerosol composition, and flow characterization. Multiple aerosol generation systems enable dispersion of both liquid solutions or suspensions and dry powders, producing particle concentrations from 50 to 3,000 μg/m3 and the ability to detect particles across a mean diameter range of 50 nm to 20 μm. Facility validation was conducted using multiple test chemicals including caffeine, oleic acid, phenanthrene, glycerol, tributyl phosphate, and Arizona test dust for three nominal concentration levels (low ∼100, medium ∼500, high >800 μg/m3). Aerosol concentration uniformity across the flow cross-section showed relative standard deviations below 3.5%. Multi-instrument comparisons between redundant particle sizing systems (dual APS units, UHSAS, and Promo) demonstrated good measurement consistency, with gravimetric validation confirming total aerosol mass concentrations with a 20% difference between the types of measurements. The Aerodyne Aerosol Mass Spectrometer correctly identified particle chemical signatures consistent with NIST fragmentation patterns for all test compounds. The facility employs shrouded probe sampling systems with isokinetic coupling to individual instruments to minimize particle losses and sampling biases across the particle size distribution. The AATF provides a repeatable and reliable aerosol generation testbed for detector development, evaluation, instrument intercomparison, and aerosol measurement validation under controlled yet realistic ambient air conditions with controlled size distributions and total mass concentrations for a wide range of chemical aerosols.
- 11 January 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-23
Open AccessDevelopment and Validation of an Integrated Ambient Air Test Facility (AATF) for Multi-Instrument Aerosol Characterization
The U.S. Naval Research Laboratory has developed and validated an Ambient Air Test Facility (AATF) for controlled multi-instrument aerosol generation and characterization under realistic sampling conditions. The facility consists of a 14 meter flow tube system that provides turbulent (Re = 40,000) outdoor ambient air flow at 2 m/s for testing aerosol detection and measurement systems in a controlled indoor environment. The AATF integrates 13 diagnostic instruments across four measurement categories: individual particle measurement, aerosol loading, aerosol composition, and flow characterization. Multiple aerosol generation systems enable dispersion of both liquid solutions or suspensions and dry powders, producing particle concentrations from 50 to 3,000 μg/m3 and the ability to detect particles across a mean diameter range of 50 nm to 20 μm. Facility validation was conducted using multiple test chemicals including caffeine, oleic acid, phenanthrene, glycerol, tributyl phosphate, and Arizona test dust for three nominal concentration levels (low ∼100, medium ∼500, high >800 μg/m3). Aerosol concentration uniformity across the flow cross-section showed relative standard deviations below 3.5%. Multi-instrument comparisons between redundant particle sizing systems (dual APS units, UHSAS, and Promo) demonstrated good measurement consistency, with gravimetric validation confirming total aerosol mass concentrations with a 20% difference between the types of measurements. The Aerodyne Aerosol Mass Spectrometer correctly identified particle chemical signatures consistent with NIST fragmentation patterns for all test compounds. The facility employs shrouded probe sampling systems with isokinetic coupling to individual instruments to minimize particle losses and sampling biases across the particle size distribution. The AATF provides a repeatable and reliable aerosol generation testbed for detector development, evaluation, instrument intercomparison, and aerosol measurement validation under controlled yet realistic ambient air conditions with controlled size distributions and total mass concentrations for a wide range of chemical aerosols.
- Open Access
- 5 January 2026
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 42 (2) , 1938-1946
Optical Analysis of Cyclic Voltammetry of Ferrocenemethanol: A Comparative Study of SPR and LSPR
This study integrates optical and electrochemical techniques to examine electrochemical activity at gold electrodes, focusing on the redox behavior of ferrocenemethanol as a model system. By combining Surface Plasmon Resonance (SPR) and Localized Surface Plasmon Resonance (LSPR) imaging with cyclic voltammetry (CV), spatial and electrochemical aspects of interfacial reactions are revealed. SPR provides broad-area sensitivity to refractive index changes, while LSPR offers high spatial resolution at the nanoscale. The incorporation of semioperational transformations into the analysis of voltametric data enhances the identification of electrochemical parameters and promotes more direct correlations between optical signals and underlying redox reaction mechanisms. In this work, LSPR is introduced as an electro-optical plasmonic method that has been relatively underexplored for redox probe behavior at the nanoscale, which confirms the well-established electrochemical-SPR approach. This comprehensive approach enriches the understanding of heterogeneous electron transfer processes, providing insights that can guide the development of advanced sensors, catalytic surfaces, and other electrochemical technologies.
- 5 January 2026
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 42 (2) , 1938-1946
Open AccessOptical Analysis of Cyclic Voltammetry of Ferrocenemethanol: A Comparative Study of SPR and LSPR
This study integrates optical and electrochemical techniques to examine electrochemical activity at gold electrodes, focusing on the redox behavior of ferrocenemethanol as a model system. By combining Surface Plasmon Resonance (SPR) and Localized Surface Plasmon Resonance (LSPR) imaging with cyclic voltammetry (CV), spatial and electrochemical aspects of interfacial reactions are revealed. SPR provides broad-area sensitivity to refractive index changes, while LSPR offers high spatial resolution at the nanoscale. The incorporation of semioperational transformations into the analysis of voltametric data enhances the identification of electrochemical parameters and promotes more direct correlations between optical signals and underlying redox reaction mechanisms. In this work, LSPR is introduced as an electro-optical plasmonic method that has been relatively underexplored for redox probe behavior at the nanoscale, which confirms the well-established electrochemical-SPR approach. This comprehensive approach enriches the understanding of heterogeneous electron transfer processes, providing insights that can guide the development of advanced sensors, catalytic surfaces, and other electrochemical technologies.
- 24 March 2025
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 8 (13) , 6419-6434
Systematic Development of a Plasmon Ruler Using Dithiolate-Grafted Gold Nanoparticle for High-Throughput Screening of Anti-Icing Activity
- 24 March 2025
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 8 (13) , 6419-6434
Systematic Development of a Plasmon Ruler Using Dithiolate-Grafted Gold Nanoparticle for High-Throughput Screening of Anti-Icing Activity
- 2 November 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (23) , 42276-42282
Active aerosols
We report the dynamics and control of the orientational and positional order of ensembles of gold nanorods suspended in air at standard temperature and pressure using externally applied electric fields, demonstrating an active aerosol. Light filter, valve and gradient responses are shown, establishing active aerosols as a unique type of optical element we term component-less optics.
- 2 November 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (23) , 42276-42282
Active aerosols
We report the dynamics and control of the orientational and positional order of ensembles of gold nanorods suspended in air at standard temperature and pressure using externally applied electric fields, demonstrating an active aerosol. Light filter, valve and gradient responses are shown, establishing active aerosols as a unique type of optical element we term component-less optics.