Hui Dong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Hui Dong has a total of 92 co-authors. Here are the top co-authors by number of shared publications:
Yanli Zhou
15 shared publicationsMaotian Xu
11 shared publications- Maotian Xu
College of Chemistry and Chemical Engineering, Shangqiu Normal University, Shangqiu 476000, China
9 shared publications Yintang Zhang
College of Chemistry, Zhengzhou University, Zhengzhou 450001, China
7 shared publicationsXu Zhu
Henan Key Laboratory of Biomolecular Recognition and Sensing, Henan Joint, International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, College of Chemistry and Chemical Engineering, Shangqiu Normal University, Shangqiu, China
6 shared publications- Yanli Zhou
Shangqiu Normal University
6 shared publications
Latest Publications
- 25 July 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (31) , 23335-23345
Dual-Mode Turn-On Fluorescent and Ratiometric Electrochemical Detection of Cu2 + in Alzheimer’s Disease Mouse Brains Based on a Single Resorufin–Picolinate Probe
Copper ions (Cu2+) are closely implicated in the pathogenesis of Alzheimer’s disease (AD) by mediating oxidative stress and promoting β-amyloid (Aβ) aggregation. Accurate quantification of labile Cu2+ in the brain extracellular microenvironment is critical for elucidating its pathological roles and developing AD diagnostic tools. Herein, we report a dual-mode sensing platform integrating “turn-on” fluorescence and ratiometric electrochemistry for sensitive and selective Cu2+ quantification, based on a resorufin-picolinate conjugate (RP) probe and a carbon nanotube-modified carbon fiber microelectrode (CFME/CNT). Resorufin (Re) acts as both the fluorescent reporter and electrochemical redox center, while picolinate serves as the Cu2+-specific recognition moiety. Cu2+ coordinates with picolinate to catalyze the ester hydrolysis of RP, releasing free Re that triggers a fluorescence enhancement at 594 nm and a ratiometric electrochemical response, corresponding to the oxidation currents of free Re and intact RP, respectively. The RP probe exhibits high selectivity for Cu2+ over other metal ions, with limits of detection of 19 nM (fluorescence) and 7.2 nM (electrochemistry). The dual-mode platform was successfully applied to the accurate quantification of endogenous labile Cu2+ in cerebral cortex dialysate from AD mice and age-matched wild-type (WT) mice, and noninvasive in vivo fluorescence imaging further confirmed the elevated Cu2+ level in living AD mouse brains. Quantitative results revealed that the labile Cu2+ concentration in AD mouse cerebral cortex dialysate was significantly higher than that in WT mice. The two detection modes yielded highly consistent results, validating the reliability of the dual-mode platform in complex biological matrices. This dual-mode strategy synergizes the merits of fluorescence and ratiometric electrochemistry, providing a robust and selective tool for investigating AD pathogenesis related to Cu2+ dyshomeostasis and holds great potential for clinical translational applications in AD diagnosis.
- 25 July 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (31) , 23335-23345
Dual-Mode Turn-On Fluorescent and Ratiometric Electrochemical Detection of Cu2 + in Alzheimer’s Disease Mouse Brains Based on a Single Resorufin–Picolinate Probe
Copper ions (Cu2+) are closely implicated in the pathogenesis of Alzheimer’s disease (AD) by mediating oxidative stress and promoting β-amyloid (Aβ) aggregation. Accurate quantification of labile Cu2+ in the brain extracellular microenvironment is critical for elucidating its pathological roles and developing AD diagnostic tools. Herein, we report a dual-mode sensing platform integrating “turn-on” fluorescence and ratiometric electrochemistry for sensitive and selective Cu2+ quantification, based on a resorufin-picolinate conjugate (RP) probe and a carbon nanotube-modified carbon fiber microelectrode (CFME/CNT). Resorufin (Re) acts as both the fluorescent reporter and electrochemical redox center, while picolinate serves as the Cu2+-specific recognition moiety. Cu2+ coordinates with picolinate to catalyze the ester hydrolysis of RP, releasing free Re that triggers a fluorescence enhancement at 594 nm and a ratiometric electrochemical response, corresponding to the oxidation currents of free Re and intact RP, respectively. The RP probe exhibits high selectivity for Cu2+ over other metal ions, with limits of detection of 19 nM (fluorescence) and 7.2 nM (electrochemistry). The dual-mode platform was successfully applied to the accurate quantification of endogenous labile Cu2+ in cerebral cortex dialysate from AD mice and age-matched wild-type (WT) mice, and noninvasive in vivo fluorescence imaging further confirmed the elevated Cu2+ level in living AD mouse brains. Quantitative results revealed that the labile Cu2+ concentration in AD mouse cerebral cortex dialysate was significantly higher than that in WT mice. The two detection modes yielded highly consistent results, validating the reliability of the dual-mode platform in complex biological matrices. This dual-mode strategy synergizes the merits of fluorescence and ratiometric electrochemistry, providing a robust and selective tool for investigating AD pathogenesis related to Cu2+ dyshomeostasis and holds great potential for clinical translational applications in AD diagnosis.
- 18 May 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (21) , 4433-4443
A dual mode turn-on probe for H 2 O 2 sensing via fluorescence and colorimetry in live cells and serum
Hydrogen peroxide (H 2 O 2 ), as a crucial intracellular reactive oxygen species (ROS) and secondary messenger, plays a key role in various physiological and pathological processes.
- 18 May 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (21) , 4433-4443
A dual mode turn-on probe for H 2 O 2 sensing via fluorescence and colorimetry in live cells and serum
Hydrogen peroxide (H 2 O 2 ), as a crucial intracellular reactive oxygen species (ROS) and secondary messenger, plays a key role in various physiological and pathological processes.
- 2 February 2026
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 9 (6) , 2836-2846
Construction of a Nanozyme Sensor Based on α-Fe 2 O 3 /ZIF-67 Composite for Sensitive Colorimetric Detection of H 2 S and Cu 2+
- 2 February 2026
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 9 (6) , 2836-2846
Construction of a Nanozyme Sensor Based on α-Fe 2 O 3 /ZIF-67 Composite for Sensitive Colorimetric Detection of H 2 S and Cu 2+
- 4 December 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (49) , 27316-27324
A Turn-On Fluorescent and Ratiometric Electrochemical Dual-Mode Probe for Hydrogen Peroxide Detection in Brain Microdialysates of Alzheimer’s Disease Mice
Hydrogen peroxide (H2O2), a pivotal reactive oxygen species (ROS), is closely linked to oxidative stress in the pathogenesis of Alzheimer's disease (AD). Herein, we report a dual-mode probe (Re-PS) integrating turn-on fluorescence and ratiometric electrochemistry for the selective detection of H2O2 in brain microdialysates of AD model mice. The probe is constructed using resorufin (Re) as a dual-signal reporter and a pentafluorobenzenesulfonyl (PS) group as the H2O2-responsive unit. Upon reaction with H2O2, the PS group undergoes nucleophilic substitution, leading to the release of Re; this process triggers a fluorescence "turn-on" response and generates a ratiometric electrochemical signal. Compared with ester-based probes, Re-PS shows superior stability due to the strong electron-withdrawing effect of fluorine atoms in the PS group. The fluorescence mode achieves a detection limit (LOD) of 50 nM, while the electrochemical detection mode (using a carbon fiber microelectrode modified with carbon nanotubes (CFME/CNT)) has a detection range of 1.0-50 μM. Both modes exhibit excellent selectivity against other ROS and biomolecules. In vivo microdialysis analysis reveals significantly elevated H2O2 levels in the brains of AD mice (28.6 ± 3.2 μM) compared with wild-type mice (10.3 ± 1.8 μM). This dual-mode strategy enables cross-validation, providing a reliable tool for monitoring oxidative stress in neurodegenerative diseases.
- 4 December 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (49) , 27316-27324
A Turn-On Fluorescent and Ratiometric Electrochemical Dual-Mode Probe for Hydrogen Peroxide Detection in Brain Microdialysates of Alzheimer’s Disease Mice
Hydrogen peroxide (H2O2), a pivotal reactive oxygen species (ROS), is closely linked to oxidative stress in the pathogenesis of Alzheimer's disease (AD). Herein, we report a dual-mode probe (Re-PS) integrating turn-on fluorescence and ratiometric electrochemistry for the selective detection of H2O2 in brain microdialysates of AD model mice. The probe is constructed using resorufin (Re) as a dual-signal reporter and a pentafluorobenzenesulfonyl (PS) group as the H2O2-responsive unit. Upon reaction with H2O2, the PS group undergoes nucleophilic substitution, leading to the release of Re; this process triggers a fluorescence "turn-on" response and generates a ratiometric electrochemical signal. Compared with ester-based probes, Re-PS shows superior stability due to the strong electron-withdrawing effect of fluorine atoms in the PS group. The fluorescence mode achieves a detection limit (LOD) of 50 nM, while the electrochemical detection mode (using a carbon fiber microelectrode modified with carbon nanotubes (CFME/CNT)) has a detection range of 1.0-50 μM. Both modes exhibit excellent selectivity against other ROS and biomolecules. In vivo microdialysis analysis reveals significantly elevated H2O2 levels in the brains of AD mice (28.6 ± 3.2 μM) compared with wild-type mice (10.3 ± 1.8 μM). This dual-mode strategy enables cross-validation, providing a reliable tool for monitoring oxidative stress in neurodegenerative diseases.
- 17 September 2025
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 61 (84) , 16420-16423
A pseudo-circular DNA walker-mediated electrochemical biosensor for sensitive detection of the apolipoprotein E4 gene
In this work, we report a pseudo-circular DNA walker (PDW) integrated with G-quadruplex (G4) and triplex DNA to construct an electrochemical biosensor for ultrasensitive detection of apolipoprotein E4 (T-e4). PDW contains double embedded DNAzyme sequences, leveraging the intrinsic advantages of enhanced structural rigidity for stable spatial conformation, continuous autonomous rolling capability, and efficient cyclic cleavage of hairpin probes due to its closed-loop topology. After binding to the target, the catalytic domain of the PDW is activated, rolling and cutting the hairpin probe in the presence of Mg2+. The triplex helix hairpin orbital (THO) serves as a rigid scaffold to immobilize hairpin DNA probes, enhancing interfacial stability and signal probe loading efficiency. The cleavage releases G-rich DNA fragments, which subsequently self-assemble into hemin/G-quadruplex (HG4) nanostructures. This design achieves label-free detection with exceptional sensitivity, exhibiting a linear range of 0.05–10 pM and a detection limit of 27 fM. This strategy opens up a new way for the sensitive detection of neurodegenerative disease biomarkers and shows broad application prospects in the fields of early disease screening and clinical monitoring.
- 17 September 2025
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 61 (84) , 16420-16423
A pseudo-circular DNA walker-mediated electrochemical biosensor for sensitive detection of the apolipoprotein E4 gene
In this work, we report a pseudo-circular DNA walker (PDW) integrated with G-quadruplex (G4) and triplex DNA to construct an electrochemical biosensor for ultrasensitive detection of apolipoprotein E4 (T-e4). PDW contains double embedded DNAzyme sequences, leveraging the intrinsic advantages of enhanced structural rigidity for stable spatial conformation, continuous autonomous rolling capability, and efficient cyclic cleavage of hairpin probes due to its closed-loop topology. After binding to the target, the catalytic domain of the PDW is activated, rolling and cutting the hairpin probe in the presence of Mg2+. The triplex helix hairpin orbital (THO) serves as a rigid scaffold to immobilize hairpin DNA probes, enhancing interfacial stability and signal probe loading efficiency. The cleavage releases G-rich DNA fragments, which subsequently self-assemble into hemin/G-quadruplex (HG4) nanostructures. This design achieves label-free detection with exceptional sensitivity, exhibiting a linear range of 0.05–10 pM and a detection limit of 27 fM. This strategy opens up a new way for the sensitive detection of neurodegenerative disease biomarkers and shows broad application prospects in the fields of early disease screening and clinical monitoring.
- 30 July 2025
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 8 (31) , 15495-15503
“Signal-On” Photoelectrochemical Biosensor Based on CdS Quantum Dot/ZnO and Ag Nanoparticles for Sensitive Determination of Interleukin-6
- 30 July 2025
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 8 (31) , 15495-15503
“Signal-On” Photoelectrochemical Biosensor Based on CdS Quantum Dot/ZnO and Ag Nanoparticles for Sensitive Determination of Interleukin-6
- 3 July 2025
- Published by Springer Nature in Microchimica Acta
- Vol. 192 (8) , 1-12
Ultrasonic-assisted molecular probe for turn-on electrochemical and fluorescence dual-mode detection of GSH in human serum
A molecular probe, 3-oxo-3H-phenoxazin-7-yl thiophene-2-carboxylate (RD), was synthesized using resorufin (Re) as the substrate for the specific recognition of glutathione (GSH). Ultrasonic waves were employed to enhance the reaction efficiency between the molecular probe and GSH. The molecular probe was designed to exhibit specific recognition ability for GSH. In the absence of GSH, the probe’s fluorescence is quenched; in the presence of GSH, a specific reaction restores the fluorescence intensity, achieving “turn-on” fluorescence detection. The detection limit for GSH was 5.52 μM, with a linear range of 5 μM to 1.2 mM. Additionally, an electrochemical detection method was integrated. The interaction between GSH and the modified electrode surface induces a change in the electrochemical signal, which can be used for the quantitative determination of GSH. The detection limit for GSH using this method was 8 μM, with a linear range of 10 μM to 1.2 mM. By combining these two detection modes, the reliability and accuracy of glutathione detection were significantly improved. Furthermore, the practical application of this method in human serum samples demonstrated its good selectivity and anti-interference ability, providing a reliable dual-mode analysis platform for clinical GSH detection. Graphical Abstract
- 3 July 2025
- Published by Springer Nature in Microchimica Acta
- Vol. 192 (8) , 1-12
Ultrasonic-assisted molecular probe for turn-on electrochemical and fluorescence dual-mode detection of GSH in human serum
A molecular probe, 3-oxo-3H-phenoxazin-7-yl thiophene-2-carboxylate (RD), was synthesized using resorufin (Re) as the substrate for the specific recognition of glutathione (GSH). Ultrasonic waves were employed to enhance the reaction efficiency between the molecular probe and GSH. The molecular probe was designed to exhibit specific recognition ability for GSH. In the absence of GSH, the probe’s fluorescence is quenched; in the presence of GSH, a specific reaction restores the fluorescence intensity, achieving “turn-on” fluorescence detection. The detection limit for GSH was 5.52 μM, with a linear range of 5 μM to 1.2 mM. Additionally, an electrochemical detection method was integrated. The interaction between GSH and the modified electrode surface induces a change in the electrochemical signal, which can be used for the quantitative determination of GSH. The detection limit for GSH using this method was 8 μM, with a linear range of 10 μM to 1.2 mM. By combining these two detection modes, the reliability and accuracy of glutathione detection were significantly improved. Furthermore, the practical application of this method in human serum samples demonstrated its good selectivity and anti-interference ability, providing a reliable dual-mode analysis platform for clinical GSH detection. Graphical Abstract
- 29 April 2025
- Published by Elsevier in Bioelectrochemistry
- Vol. 165, 108995
Two-mode ratiometric electrochemical and turn-on fluorescence strategy for detecting biothiols in serum with all-in-one molecular probe
- 29 April 2025
- Published by Elsevier in Bioelectrochemistry
- Vol. 165, 108995
Two-mode ratiometric electrochemical and turn-on fluorescence strategy for detecting biothiols in serum with all-in-one molecular probe
- Open Access
- 14 February 2025
- Published by Elsevier in Sensors and Actuators Reports
- Vol. 9
Dual-mode ratiometric electrochemical and turn-on fluorescent probe for reliably detecting H2O2 in Parkinson's disease serum
- 14 February 2025
- Published by Elsevier in Sensors and Actuators Reports
- Vol. 9
Open AccessDual-mode ratiometric electrochemical and turn-on fluorescent probe for reliably detecting H2O2 in Parkinson's disease serum