Muhammad Musavir Bilal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Muhammad Musavir Bilal has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Hamza Ahmad Madni
College of Electronic and Information Engineering, Beibu Gulf University, Qinzhou 535011, China
4 shared publications - Servando Lopez-Aguayo
Tecnológico de Monterrey, Escuela de Ingeniería y Ciencias
4 shared publications - Ajmal Thottoli
NanoPhotonics and Electromagnetics Group, Electrical and Information Engineering Department, Polytechnic University of Bari, Via E. Orabona 4, 70125 Bari, Italy
3 shared publications Weihong Bi
School of Information Science and Engineering, Key Laboratory for Special Fiber and Fiber Sensor of Hebei Province, Yanshan University, Qinhuangdao City, Hebei Province 066004, China
3 shared publicationsFarrukh Jaleel
Department of Chemistry, Khwaja Fareed University of Engineering and Information Technology, Rahim Yar Khan, Pakistan
2 shared publicationsJin Wa
Yanshan University, College of Information Science and Engineering, Hebei
2 shared publications
Latest Publications
- Open Access
- 17 October 2023
- Published by MDPI AG in Preprints.org
Numerical and Experimental Analysis of Side Polished Single Mode Fiber for Refractive Index Sensing
In this paper, we introduced a comprehensive study, based on both numerical and experimental analyses, of side polished (SP) single mode fibers (SMF) to investigate their evanescent field interaction with air and liquid analytes. In particular, the finite element method (FEM) and the beam propagation method (BPM) are employed to predict the optical properties of the SP-SMF. An ad-hoc experimental setup has been designed and built to characterize the side polished single mode fiber when air, water, and isopropanol are set in the side polished region. The sensitivity of the analytes is obtained as 1.207 V/RIU. The performance in terms of effective refractive index and transmittance are reported to show how these SP-SMF can be efficiently used for calculating the liquid refractive index. The simulation and experimental results display the significant performance of the SP-SMF as a sensing element.
- 17 October 2023
- Published by MDPI AG in Preprints.org
Open AccessNumerical and Experimental Analysis of Side Polished Single Mode Fiber for Refractive Index Sensing
In this paper, we introduced a comprehensive study, based on both numerical and experimental analyses, of side polished (SP) single mode fibers (SMF) to investigate their evanescent field interaction with air and liquid analytes. In particular, the finite element method (FEM) and the beam propagation method (BPM) are employed to predict the optical properties of the SP-SMF. An ad-hoc experimental setup has been designed and built to characterize the side polished single mode fiber when air, water, and isopropanol are set in the side polished region. The sensitivity of the analytes is obtained as 1.207 V/RIU. The performance in terms of effective refractive index and transmittance are reported to show how these SP-SMF can be efficiently used for calculating the liquid refractive index. The simulation and experimental results display the significant performance of the SP-SMF as a sensing element.
- Open Access
Numerical Analysis of Solid-Core Photonic Crystal Fiber Based on Plasmonic Materials for Analyte Refractive Index Sensing
In this study, we presented a simple highly sensitive sensor based on commercially available solid-core photonic crystal fiber (PCF) and surface plasmon resonance (SPR) for measuring the refractive index (RI) of analytes. The numerical simulation based on the finite element method (FEM) has been examined to compute the optical properties such as confinement loss, power spectrum, and transmission intensity of the sensor. The most sensitive and inert plasmonic materials (gold and silver) have been assumed to be coated inside the fiber with the range of analyte RI from 1.32 to 1.40. The performance of the proposed sensor has been evaluated by tracing the several optical features like wavelength sensitivity, amplitude sensitivity, resolution of the sensor, and figure of merit. As a result, the comparative study between silver and gold elements has been carried out in which the maximum sensitivity received was 1.15 μm/RIU and 1.10 μm/RIU, respectively. Whereas, on the base of power spectrum, the obtained sensitivity was 513 μm/RIU for the gold layer. Moreover, the effect of other structural parameters (air holes and plasmonic layer thickness) on the sensing performance has been taken into an account. According to the simulation analysis and results, this sensor would have a great potential in various sensing applications of biomedical and liquid refractive index.
Open AccessNumerical Analysis of Solid-Core Photonic Crystal Fiber Based on Plasmonic Materials for Analyte Refractive Index Sensing
In this study, we presented a simple highly sensitive sensor based on commercially available solid-core photonic crystal fiber (PCF) and surface plasmon resonance (SPR) for measuring the refractive index (RI) of analytes. The numerical simulation based on the finite element method (FEM) has been examined to compute the optical properties such as confinement loss, power spectrum, and transmission intensity of the sensor. The most sensitive and inert plasmonic materials (gold and silver) have been assumed to be coated inside the fiber with the range of analyte RI from 1.32 to 1.40. The performance of the proposed sensor has been evaluated by tracing the several optical features like wavelength sensitivity, amplitude sensitivity, resolution of the sensor, and figure of merit. As a result, the comparative study between silver and gold elements has been carried out in which the maximum sensitivity received was 1.15 μm/RIU and 1.10 μm/RIU, respectively. Whereas, on the base of power spectrum, the obtained sensitivity was 513 μm/RIU for the gold layer. Moreover, the effect of other structural parameters (air holes and plasmonic layer thickness) on the sensing performance has been taken into an account. According to the simulation analysis and results, this sensor would have a great potential in various sensing applications of biomedical and liquid refractive index.
- Open Access
- 25 August 2023
- Published by MDPI AG in Preprints.org
Numerical Analysis of Solid Core Photonic Crystal Fiber Based on Plasmonic Materials for Analytes Refractive Index Sensing
In this study, we presented a simple highly sensitive sensor based on commercially available solid core photonic crystal fiber (PCF) and surface plasmon resonance (SPR) for measuring the refractive index (RI) of analytes. The numerical simulation based on the finite element method (FEM) has been examined to compute the optical properties such as confinement loss, power spectrum, and transmission intensity of the sensor. The most sensitive and inert plasmonic materials (gold and silver) have been assumed to be coated inside the fiber with the range of analytes RI from 1.32 to 1.40. The performance of the proposed sensor has been evaluated by tracing the several optical features like wavelength sensitivity, amplitude sensitivity, resolution of the sensor, and figure of merit. As a result, the comparative study between silver and gold elements has been carried out in which the maximum sensitivity received as 1.15 μm/RIU and 1.10 μm/RIU respectively. Whereas, on the base of power spectrum the obtained sensitivity was 513 μm/RIU for the gold layer. Moreover, the effect of other structural parameters (air holes and plasmonic layers thickness) on the sensing performance has been taken into an account. According to the simulation analysis and results, this sensor would have a great potential in various sensing applications of biomedical and liquid refractive index.
- 25 August 2023
- Published by MDPI AG in Preprints.org
Open AccessNumerical Analysis of Solid Core Photonic Crystal Fiber Based on Plasmonic Materials for Analytes Refractive Index Sensing
In this study, we presented a simple highly sensitive sensor based on commercially available solid core photonic crystal fiber (PCF) and surface plasmon resonance (SPR) for measuring the refractive index (RI) of analytes. The numerical simulation based on the finite element method (FEM) has been examined to compute the optical properties such as confinement loss, power spectrum, and transmission intensity of the sensor. The most sensitive and inert plasmonic materials (gold and silver) have been assumed to be coated inside the fiber with the range of analytes RI from 1.32 to 1.40. The performance of the proposed sensor has been evaluated by tracing the several optical features like wavelength sensitivity, amplitude sensitivity, resolution of the sensor, and figure of merit. As a result, the comparative study between silver and gold elements has been carried out in which the maximum sensitivity received as 1.15 μm/RIU and 1.10 μm/RIU respectively. Whereas, on the base of power spectrum the obtained sensitivity was 513 μm/RIU for the gold layer. Moreover, the effect of other structural parameters (air holes and plasmonic layers thickness) on the sensing performance has been taken into an account. According to the simulation analysis and results, this sensor would have a great potential in various sensing applications of biomedical and liquid refractive index.
- 5 December 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (35) , 10400-10407
Multi-functional sensor based on photonic crystal fiber using plasmonic material and magnetic fluid
A unique highly sensitive photonic crystal fiber, to the best of our knowledge, is investigated based on plasmonic material and magnetic fluid (MF) for the simultaneous measurement of temperature and magnetic field sensor. The designed sensor is explored by tracing the different parameters such as birefringence, coupling length, power spectrum, and the peak wavelength of the transmission intensity. The magnetic field and temperature computation are attained simultaneously by examining the linear fitting curve and the movement of transmission peaks. The obtained sensitivity for temperature is 7.1 nm/°C with an exposure range of 25°C to 100°C. In contrast, the magnetic field sensitivity is 12 nm/Oe with a detection range of 160–200 Oe. In addition, the resolutions are − 1.245 ∘ C and 5.53 Oe for temperature and magnetic field, respectively. Our inspected sensor is used to detect extremely low and high values of magnetic fields. The investigated structure is presented with simplification, compactness, easy implementation, and high sensitivity, which is expected to be a good foundation for the advancement of optical sensing devices in the future applications of industries, security, small grids, and environmental systems.
- 5 December 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (35) , 10400-10407
Multi-functional sensor based on photonic crystal fiber using plasmonic material and magnetic fluid
A unique highly sensitive photonic crystal fiber, to the best of our knowledge, is investigated based on plasmonic material and magnetic fluid (MF) for the simultaneous measurement of temperature and magnetic field sensor. The designed sensor is explored by tracing the different parameters such as birefringence, coupling length, power spectrum, and the peak wavelength of the transmission intensity. The magnetic field and temperature computation are attained simultaneously by examining the linear fitting curve and the movement of transmission peaks. The obtained sensitivity for temperature is 7.1 nm/°C with an exposure range of 25°C to 100°C. In contrast, the magnetic field sensitivity is 12 nm/Oe with a detection range of 160–200 Oe. In addition, the resolutions are − 1.245 ∘ C and 5.53 Oe for temperature and magnetic field, respectively. Our inspected sensor is used to detect extremely low and high values of magnetic fields. The investigated structure is presented with simplification, compactness, easy implementation, and high sensitivity, which is expected to be a good foundation for the advancement of optical sensing devices in the future applications of industries, security, small grids, and environmental systems.
- 6 June 2022
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 54 (7) , 1-14
Shrinking-shifting and amplifying-shifting device using transformation optics
- 6 June 2022
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 54 (7) , 1-14
Shrinking-shifting and amplifying-shifting device using transformation optics
- Open Access
- 23 June 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (14) , 20062-20073
Highly sensitive temperature sensing probes based on liquid cladding elliptical micro/nanofibers
A highly sensitive temperature probe based on a liquid cladding elliptical micro/nanofiber is proposed, which exploits a fiber loop mirror with an output port probe for remote and highly-sensitive measurements based on evanescent field coupling. The thermo-optical effective liquid cladding avoids the influence of other environmental parameters (except for temperature), while protecting the micro/nanofibers from external disturbance and contamination. This renders the sensing probe only sensitive to temperature changes, making it suitable for real-world temperature measurements. An isopropanol cladding elliptical microfiber with a diameter of 3.4 µm demonstrated a sensitivity of −16.38 nm/°C for a remote temperature measurement.
- 23 June 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (14) , 20062-20073
Open AccessHighly sensitive temperature sensing probes based on liquid cladding elliptical micro/nanofibers
A highly sensitive temperature probe based on a liquid cladding elliptical micro/nanofiber is proposed, which exploits a fiber loop mirror with an output port probe for remote and highly-sensitive measurements based on evanescent field coupling. The thermo-optical effective liquid cladding avoids the influence of other environmental parameters (except for temperature), while protecting the micro/nanofibers from external disturbance and contamination. This renders the sensing probe only sensitive to temperature changes, making it suitable for real-world temperature measurements. An isopropanol cladding elliptical microfiber with a diameter of 3.4 µm demonstrated a sensitivity of −16.38 nm/°C for a remote temperature measurement.
- 25 September 2019
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 58 (09) , 096107-6
Magnetic field sensor based on the magnetic fluid infiltration into the cladding air holes of the solid-core photonic crystal fiber
A magnetic field sensor based on the magnetic fluid injected into all the cladding air holes of the solid core photonic crystal fiber (PCF) is proposed. The 8.5 cm length of the PCF filled with magnetic fluid relates to single mode fiber to compose a Mach–Zehnder interferometer. The sensor relies on the tunable refractive index of the magnetic fluid and the characteristics of the PCF. A series of magnetic field strength is applied to this sensing structure. From the experimental results, the sensitivity of the magnetic field sensor is obtained as 7.055 × 10 − 4 dB / nT while a small change in wavelength shift is found. Due to a simple and easy fabrication technique, high sensitivity, and compactness, we are confident that the proposed sensor will find potential applications in measuring the magnetic field.
- 25 September 2019
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 58 (09) , 096107-6
Magnetic field sensor based on the magnetic fluid infiltration into the cladding air holes of the solid-core photonic crystal fiber
A magnetic field sensor based on the magnetic fluid injected into all the cladding air holes of the solid core photonic crystal fiber (PCF) is proposed. The 8.5 cm length of the PCF filled with magnetic fluid relates to single mode fiber to compose a Mach–Zehnder interferometer. The sensor relies on the tunable refractive index of the magnetic fluid and the characteristics of the PCF. A series of magnetic field strength is applied to this sensing structure. From the experimental results, the sensitivity of the magnetic field sensor is obtained as 7.055 × 10 − 4 dB / nT while a small change in wavelength shift is found. Due to a simple and easy fabrication technique, high sensitivity, and compactness, we are confident that the proposed sensor will find potential applications in measuring the magnetic field.
- 6 March 2019
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 58 (07) , 1-6
Magnetic fluid-based photonic crystal fiber for temperature sensing
A temperature-sensor is presented based on the solid core photonic crystal fiber (PCF) infiltrated with the magnetic fluid (MF) in all or some parts of the cladding air holes with the help of the syringe injection technique. The 8.5-cm length of the proposed PCF sensor is used. A Mach–Zehnder interferometer modal is used for the detection process. The applied temperature is given in a range from 25.6°C to 100.1°C. The calculated outcome justifies that a very clear interference spectrum is obtained between the change of the refractive index of the MF and the temperature. From the experimental outputs, the temperature sensitivity of the intended PCF is −0.38 nm / ° C, and at high temperature, it achieves 0.176 nm / ° C. The MF has great sensitivity at high temperature. This proposed sensing system may find potential applications in medical science and industry.
- 6 March 2019
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 58 (07) , 1-6
Magnetic fluid-based photonic crystal fiber for temperature sensing
A temperature-sensor is presented based on the solid core photonic crystal fiber (PCF) infiltrated with the magnetic fluid (MF) in all or some parts of the cladding air holes with the help of the syringe injection technique. The 8.5-cm length of the proposed PCF sensor is used. A Mach–Zehnder interferometer modal is used for the detection process. The applied temperature is given in a range from 25.6°C to 100.1°C. The calculated outcome justifies that a very clear interference spectrum is obtained between the change of the refractive index of the MF and the temperature. From the experimental outputs, the temperature sensitivity of the intended PCF is −0.38 nm / ° C, and at high temperature, it achieves 0.176 nm / ° C. The MF has great sensitivity at high temperature. This proposed sensing system may find potential applications in medical science and industry.