Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Isabel Guedes-Guedes has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation of the degree of agreement in the diagnosis of diabetic retinopathy between ophthalmologists and EyeArt®

    by Isabel Inmaculada Guedes Guedes, Pedro Saavedra Santana, Francisco Cabrera López, Ángel Ramos Macías, Ángel Ramos de Miguel, Ayoze González Hernández

    Objective or purpose: To evaluate the diagnostic performance and agreement of the EyeArt ® Artificial Intelligence (AI) system for detecting Diabetic Retinopathy (DR), comparing its results with ophthalmologists’ assessments in a regional screening program. Design: Cross-sectional observational study. Subjects, participants, and/or controls: A total of 498 diabetic patients aged 18 years or older were enrolled between June and September 2023 through the Retisalud DR screening program in the Canary Islands. No separate control group was included. Methods: All participants underwent non-mydriatic fundus photography using the TRC-NW400 camera. Retinal images were analyzed by the EyeArt ® AI system (version 2.1.0), and results were compared with assessments by ophthalmologists based on the International Clinical Diabetic Retinopathy scale (ICDR). Agreement was quantified using Cohen’s kappa coefficient. Additionally, mixed-effects logistic regression was used to explore associations between DR and clinical risk factors. Main outcome measures: Sensitivity, specificity, and agreement (Cohen’s kappa) of the AI system compared to clinical diagnosis; predictors of DR such as age, diabetes duration, presence of Diabetic Macular Edema (DME), and central retinal thickness (CRT-OCT). Results: The EyeArt® system achieved a binocular sensitivity of 100% (95% CI: 98.1–100) and a specificity of 93.5% (95% CI: 90.2–96.0). Agreement with ophthalmologist grading was excellent, with kappa values of 0.966 (right eye) and 0.978 (left eye). Younger age, longer diabetes duration, DME presence, and higher CRT were significantly associated with DR diagnosis. Conclusions: The EyeArt ® AI system showed excellent diagnostic accuracy and strong agreement with clinical evaluations in DR screening. Nonetheless, its tendency to overestimate DR severity indicates the need for further refinement of its grading algorithm. These findings support the potential integration of AI systems into large-scale DR screening programs, pending further validation.


  • Etiology of infectious keratitis

    by C. Piña-Delgado, M. Bolaños-Rivero, I.I. Guedes Guedes, L. Siguero-Martín, I. de Miguel-Martínez


  • Open Access

    Identification of Glaucoma in Diabetics Using the Laguna-ONhE Colourimetric Method and OCT Spectralis

    by Marta Gonzalez-Hernandez, Nisamar Betancor-Caro, Fatima Mesa-Lugo, Ivan Rodriguez-Talavera, Alicia Pareja-Rios, Isabel Guedes-Guedes, Beatriz Estevez-Jorge, Maricela Trujillo-Blanco, Roberto Cordova-Villegas, Juan Espinoza-Gonzalez, et al.

    Background: Previous retrospective results are evaluated prospectively and blinded. Methods: A total of 221 eyes previously classified as normal (G1), 279 as moderate risk of glaucoma (G2) and 217 as high risk (G3) according to the Globin Discriminant Function (GDF) Laguna-ONhE index were examined with OCT Spectralis- Results: In G1, the Bruch’s Membrane Opening Minimum Rim Width (BMO-MRW) was 332 ± 55 microns; in G2, it was 252 ± 47 (p < 0.0001); and in G3, 231 ± 44 (p < 0.0001). In G1, the 1% and 5% percentiles were 233 and 248, respectively; in G2, they were lower in 28.80% and 42.29% of cases, respectively; and in G3, in 50.23% and 63.59% of cases, respectively. Most of the cases were normal-tension glaucomas. Laguna-ONhE indices showed a curvilinear correlation with BMO-MRW results. The Retinal Nerve Fibre Layer (RNFL) showed a poor relationship with BMO. Assuming G1 to be truly normal, BMO-MRW would have a Receiver operating characteristic (ROC) curve area of 0.901 for G2 and G3 and 0.651 for RNFL. A significant reduction in pixels corresponding to vessels was found in G2 and G3 vs. G1 (p < 0.0001). Conclusions: In some cases, these defects appear to be mainly glaucomatous, and in others, they are associated with diabetic microangiopathy. In normal tension glaucoma, RNFL defects may be less severe than those inside the nerve.


  • Open Access

    Glaucoma Incidence and Progression in Diabetics: The Canary Islands Study Using the Laguna ONhE Application

    by Marta Gonzalez-Hernandez, Daniel Gonzalez-Hernandez, Nisamar Betancor-Caro, Isabel Guedes-Guedes, Morten Kirk Guldager, Manuel Gonzalez de la Rosa

    Background: Laguna ONhE provides a globin distribution function (GDF), in which a glaucoma discriminator based on deep learning plays an important role, and there is also an optimized globin individual pointer (GIP) for progression analysis. Methods: Signs of optic nerve glaucoma were identified in 1,124,885 fundus images from 203,115 diabetics obtained over 15 years and 117,813 control images. Results: A total of 743,696 images from 313,040 eyes of 173,661 diabetics were analysed. Some exclusions occurred due to excessive illumination, poor quality, or the absence of optic discs. Suspicion of glaucoma was reported in 6.70%, for an intended specificity of 99% (GDF < −15). More signs of glaucoma occur in diabetics as their years of disease increase, and after age 60, compared to controls. The GIP detected progression (p < 0.01) in 2.59% of cases with 4 controls and in 42.6% with 14 controls was higher in cases with lower GDF values. The GDF was corrected for the disc area and proved to be independent of it (r = 0.001925; p = 0.2814). Conclusions: The GDF index suggests a higher and increasing glaucoma probability in diabetics over time. Doubling the number of check-ups from four to eight increases the ability to detect GIP index progression by a factor of 5.