Mahsa Saeidzadeh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mahsa Saeidzadeh has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Arash Akbari Hamed
Faculty of Civil Engineering, Sahand University of Technology, Tabriz, Iran
5 shared publications - Farid Ostadhasanzadeh Maleky
Faculty of Civil Engineering, Sahand University of Technology, Tabriz P.O. Box 513351996, Iran
2 shared publications - Hamid Reza Hassani Ghoraba
Faculty of Civil Engineering, Sahand University of Technology, Tabriz, Iran
1 shared publication - Hesam Bafandeh Nobari
Faculty of Civil Engineering, Sahand University of Technology, Tabriz, Iran
1 shared publication - Mohammad Reza Chenaghlou
Faculty of Civil Engineering, Sahand University of Technology, Tabriz, Iran
1 shared publication - Seyedeh Fatemeh Mortazavi
Faculty of Civil Engineering, Sahand University of Technology, Tabriz, Iran
1 shared publication
Latest Publications
- Open Access
- 24 October 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 53 (1) , 10
Novel Scrap Tire Rubber Pad with Steel Rods and Maglev Seismic Isolators
This research presents two innovative base isolators known as the Scrap Tire Rubber Pad with Steel Rods (STRP-SR) isolator and the Magnetic Levitated (Maglev) isolator. The STRP-SR isolator offers a cost-effective solution for low-rise buildings, while the Maglev isolator provides an ideal bearing with zero horizontal stiffness. In this study, both the STRP-SR and Maglev isolators were analyzed numerically, and the experimental specimen of the Maglev isolator was tested on a shaking table. It can be concluded numerically that both isolators have the ability to significantly reduce absolute acceleration and displacement values, with average reductions of 53.24% and 100%, respectively.
- 24 October 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 53 (1) , 10
Open AccessNovel Scrap Tire Rubber Pad with Steel Rods and Maglev Seismic Isolators
This research presents two innovative base isolators known as the Scrap Tire Rubber Pad with Steel Rods (STRP-SR) isolator and the Magnetic Levitated (Maglev) isolator. The STRP-SR isolator offers a cost-effective solution for low-rise buildings, while the Maglev isolator provides an ideal bearing with zero horizontal stiffness. In this study, both the STRP-SR and Maglev isolators were analyzed numerically, and the experimental specimen of the Maglev isolator was tested on a shaking table. It can be concluded numerically that both isolators have the ability to significantly reduce absolute acceleration and displacement values, with average reductions of 53.24% and 100%, respectively.
- Open Access
- 24 October 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 53 (1) , 12
Comparison of Two Novel Heat-Treated Beam Section and Self-Centering Pinned Connection with Friction Damper Steel Beam–Column Connections
This study presents a comparative analysis of the structural performance of two innovative steel beam–column connections, namely a self-centering pinned connection with friction damper (SC-PC-FD) and a heat-treated beam section (HBS). The findings indicate that the SC-PC-FD connection exhibits stable, flag-shaped behavior, while the HBS connection can withstand applied loadings up to a rotation of 6% without any occurrence of lateral–torsional buckling. Upon comparison of these connections, it is evident that the SC-PC-FD connection can eliminate residual drifts and provide higher ductility up to a rotation of 7%, while maintaining the main members within the elastic range.
- 24 October 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 53 (1) , 12
Open AccessComparison of Two Novel Heat-Treated Beam Section and Self-Centering Pinned Connection with Friction Damper Steel Beam–Column Connections
This study presents a comparative analysis of the structural performance of two innovative steel beam–column connections, namely a self-centering pinned connection with friction damper (SC-PC-FD) and a heat-treated beam section (HBS). The findings indicate that the SC-PC-FD connection exhibits stable, flag-shaped behavior, while the HBS connection can withstand applied loadings up to a rotation of 6% without any occurrence of lateral–torsional buckling. Upon comparison of these connections, it is evident that the SC-PC-FD connection can eliminate residual drifts and provide higher ductility up to a rotation of 7%, while maintaining the main members within the elastic range.
- Open Access
- 24 October 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 53 (1) , 11
On the Performance of Steel Buildings with Skewed Beams against Progressive Collapse
This research studies the performance of two- and four-story steel building models against progressive collapse in two cases: (1) skewed beam–column connections, and (2) straight cleated beam–beam connections. Nonlinear static and dynamic analyses were performed and then the time history analysis was performed under the simultaneous effect of the two horizontal components of three earthquake records and two column removal scenarios. The results showed that the 60-degree skewed connection had a weaker performance than the straight connection, and, according to the plastic hinge distribution, it was observed that the mentioned connection did not provide the life safety performance level.
- 24 October 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 53 (1) , 11
Open AccessOn the Performance of Steel Buildings with Skewed Beams against Progressive Collapse
This research studies the performance of two- and four-story steel building models against progressive collapse in two cases: (1) skewed beam–column connections, and (2) straight cleated beam–beam connections. Nonlinear static and dynamic analyses were performed and then the time history analysis was performed under the simultaneous effect of the two horizontal components of three earthquake records and two column removal scenarios. The results showed that the 60-degree skewed connection had a weaker performance than the straight connection, and, according to the plastic hinge distribution, it was observed that the mentioned connection did not provide the life safety performance level.
- 7 December 2022
- Published by Springer Nature in Asian Journal of Civil Engineering
- Vol. 24 (4) , 969-988
Evaluation of the seismic performance of structures equipped with novel multi-level TADAS dampers
- 7 December 2022
- Published by Springer Nature in Asian Journal of Civil Engineering
- Vol. 24 (4) , 969-988
Evaluation of the seismic performance of structures equipped with novel multi-level TADAS dampers