Byoung Hoon Choi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Byoung Hoon Choi has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Do-Un Jeong
Department of Psychiatry and Center for Sleep and Chronobiology, Seoul National University College of Medicine and Hospital, Seoul, Republic of Korea
2 shared publications - Kwang Suk Park
Seoul National University
2 shared publications - Gih Sung Chung
Interdisciplinary program of Bioengineering, Seoul National University, Seoul, Republic of Korea
1 shared publication - Hong Bum Shin
Seoul National University College of Medicine and Hospital
1 shared publication - Jin Woo Seo
Seoul National University, Graduate School
1 shared publication - Jong Min Choi
Interdisciplinary Program in Medical and Biological Engineering, Seoul National University, Graduate School, Republic of Korea
1 shared publication
Latest Publications
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 2357-2360
Noninvasive Heart Rate Variability Analysis Using Loadcell-Installed Bed During Sleep
Polysomnography is the standard method to score the sleep stages or to determine the quality of sleep. During all night examination, subjects must attach complicate and numerous electrodes on their body to acquire the biosignals. They can influence participants' sleep stage transition or sleep pattern, and the method seems intricate. In many researches, it is reported that autonomic nervous system (ANS) is varying with sleep stage transition and heart rate variability (HRV) is one of the indices which reflects the changes of autonomic nervous system. In this point of view, we can estimate the sleep quality by observing the HRV variation. In this study, to analyze the heart rate variability, we introduce a new system that can detect the heart beats of subjects during sleep by using bed installed load-cell sensors. The pressure to the sensor changes with the pulsation of the heart and we consider it as ballistocardiogram, the physical heart beat signal. To validate our system, we adopted this system for the 4 subjects with the polysomnography. The results show the LF/HF ratio of the heart rate, one of the reflection parameters of ANS, acquired from the system for each sleep stage. To validate the results, the HRV from electrocardiogram using Ag-AgCl electrodes will be compared.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 2357-2360
Noninvasive Heart Rate Variability Analysis Using Loadcell-Installed Bed During Sleep
Polysomnography is the standard method to score the sleep stages or to determine the quality of sleep. During all night examination, subjects must attach complicate and numerous electrodes on their body to acquire the biosignals. They can influence participants' sleep stage transition or sleep pattern, and the method seems intricate. In many researches, it is reported that autonomic nervous system (ANS) is varying with sleep stage transition and heart rate variability (HRV) is one of the indices which reflects the changes of autonomic nervous system. In this point of view, we can estimate the sleep quality by observing the HRV variation. In this study, to analyze the heart rate variability, we introduce a new system that can detect the heart beats of subjects during sleep by using bed installed load-cell sensors. The pressure to the sensor changes with the pulsation of the heart and we consider it as ballistocardiogram, the physical heart beat signal. To validate our system, we adopted this system for the 4 subjects with the polysomnography. The results show the LF/HF ratio of the heart rate, one of the reflection parameters of ANS, acquired from the system for each sleep stage. To validate the results, the HRV from electrocardiogram using Ag-AgCl electrodes will be compared.
- 5 December 2006
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 45 (1) , 107-114
Non-constraining sleep/wake monitoring system using bed actigraphy
This paper introduces a new method, bed actigraphy (BACT) for user-friendly sleep-wake monitoring. BACT provides a non-intrusive acquisition of activity data, and in particular does not require that sensors be attached to the subject’s body. The system consists of four load-sensing cells supporting the bed, an A/D converter, and a microcontroller with appropriate software. The performance of BACT was compared to that of standard polysomnography (PSG) recordings and wrist-worn actigraphy (ACT). Ten normal volunteers underwent overnight PSG recordings and were examined simultaneously with BACT and ACT. An automatic scoring algorithm scored each 30-s epoch of the BACT recordings for either ‘Wake’ or ‘Sleep.’ A sleep specialist manually scored the PSG recordings, and the results were divided into ‘Wake’ and ‘Sleep’ categories. The three methods showed a significant correlation when compared with in the contingency test. The mean epoch-by-epoch agreements between the BACT and PSG, ACT and PSG, and BACT and ACT recordings were 95.2, 92.9, and 94.3%, respectively. The mean absolute differences in sleep percentage (SP) between them were 1.8 ± 0.82, 3.4 ± 1.45, and 1.9 ± 1.16 %, respectively. BACT differentiation of the ‘Wake’ and ‘Sleep’ stages proved to be sufficiently robust, and its results were comparable to PSG analysis. This finding supports the experimental and clinical value of bed-activity monitoring during sleep.
- 5 December 2006
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 45 (1) , 107-114
Non-constraining sleep/wake monitoring system using bed actigraphy
This paper introduces a new method, bed actigraphy (BACT) for user-friendly sleep-wake monitoring. BACT provides a non-intrusive acquisition of activity data, and in particular does not require that sensors be attached to the subject’s body. The system consists of four load-sensing cells supporting the bed, an A/D converter, and a microcontroller with appropriate software. The performance of BACT was compared to that of standard polysomnography (PSG) recordings and wrist-worn actigraphy (ACT). Ten normal volunteers underwent overnight PSG recordings and were examined simultaneously with BACT and ACT. An automatic scoring algorithm scored each 30-s epoch of the BACT recordings for either ‘Wake’ or ‘Sleep.’ A sleep specialist manually scored the PSG recordings, and the results were divided into ‘Wake’ and ‘Sleep’ categories. The three methods showed a significant correlation when compared with in the contingency test. The mean epoch-by-epoch agreements between the BACT and PSG, ACT and PSG, and BACT and ACT recordings were 95.2, 92.9, and 94.3%, respectively. The mean absolute differences in sleep percentage (SP) between them were 1.8 ± 0.82, 3.4 ± 1.45, and 1.9 ± 1.16 %, respectively. BACT differentiation of the ‘Wake’ and ‘Sleep’ stages proved to be sufficiently robust, and its results were comparable to PSG analysis. This finding supports the experimental and clinical value of bed-activity monitoring during sleep.