Jingyao Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jingyao Ma has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Xin Zhang
College of Architecture and Energy Engineering, Wenzhou University of Technology, Wenzhou 325000, China
2 shared publications - Hao Sun
School of Resources Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China
1 shared publication - Huan Wang
School of Building Services Science and Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China
1 shared publication - Huixin Shi
CSCEC Northwest Design and Research Institute Co., Ltd., Xi’an 710018, China
1 shared publication - Kaipeng Li
School of Resources Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China
1 shared publication - Tao Yu
School of Energy and Power Engineering, Beihang University, Beijing 100191, China
1 shared publication
Latest Publications
- Open Access
Differences in Performance and Conductivity Persistence of New Reduced Graphene Oxide Air Filter Materials before and after Eliminating Static Electricity
Improving the filtration efficiency of air filter materials is an ongoing research goal. This study conducted in-depth research on a new reduced graphene oxide air filter material, and the differences in its performance and conductivity durability before and after eliminating static electricity were tested and analyzed. The results showed that the filtration efficiency of the reduced graphene oxide air filter material significantly decreased after eliminating static electricity. The maximum decrease in filtration efficiency was observed at a filtration velocity of 0.8 m/s, with PM10 > PM1.0 > PM2.5. In this case, the filtration efficiency decreased by 11.8%, 7.98%, and 7.17%, respectively. The maximum difference in filtration efficiency of 0.29 μm particulates was about 12.7%. Eliminating static electricity slightly increased the resistance (2.5~15.5 Pa). In addition, the new reduced graphene oxide air filter material exhibited good conductivity and stability after continuous testing. This study provides data support for the application of subsequent electrification sterilization, reference values for multi-angle applications, and the development of new composite air filter materials.
Open AccessDifferences in Performance and Conductivity Persistence of New Reduced Graphene Oxide Air Filter Materials before and after Eliminating Static Electricity
Improving the filtration efficiency of air filter materials is an ongoing research goal. This study conducted in-depth research on a new reduced graphene oxide air filter material, and the differences in its performance and conductivity durability before and after eliminating static electricity were tested and analyzed. The results showed that the filtration efficiency of the reduced graphene oxide air filter material significantly decreased after eliminating static electricity. The maximum decrease in filtration efficiency was observed at a filtration velocity of 0.8 m/s, with PM10 > PM1.0 > PM2.5. In this case, the filtration efficiency decreased by 11.8%, 7.98%, and 7.17%, respectively. The maximum difference in filtration efficiency of 0.29 μm particulates was about 12.7%. Eliminating static electricity slightly increased the resistance (2.5~15.5 Pa). In addition, the new reduced graphene oxide air filter material exhibited good conductivity and stability after continuous testing. This study provides data support for the application of subsequent electrification sterilization, reference values for multi-angle applications, and the development of new composite air filter materials.
- Open Access
- 9 December 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (24) , 16537
Comparison of the Application of Three Methods for the Determination of Outdoor PM2.5 Design Concentrations for Fresh Air Filtration Systems in China
With the increasing popularity of fresh-air filtration systems, the methods of determining the outdoor PM2.5 design concentration have become more important. However, the monitoring of atmospheric fine particles in China started relatively late, and there are relatively few cities with complete data, with obvious regional differences, which led to many problems in the selection of air filters for fresh-air filtration systems. In this paper, three methods of determining outdoor PM2.5 design concentration were analyzed using the daily average concentration of PM2.5 in 31 provincial capital cities from 2016 to 2020. Six typical cities in different regions were also taken as examples. The advantages and disadvantages of the three existing statistical methods were compared and analyzed, as well as the corresponding differences in the selection of outdoor PM2.5 concentration value on the filter systems. The results showed that the method of mathematical induction was more accurate and reasonable for the calculation of outdoor PM2.5 design concentrations. The local outdoor PM2.5 design concentration could be quickly calculated using the recommended coefficient K and annual average PM2.5 concentration of the region, especially for small and medium-sized cities without monitoring data. However, the recommended coefficient K should be provided based on the specific region, and should be divided into values for strict conditions and normal conditions during use. This would provide a simple and effective way to select the correct air filters for practical engineering.
- 9 December 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (24) , 16537
Open AccessComparison of the Application of Three Methods for the Determination of Outdoor PM2.5 Design Concentrations for Fresh Air Filtration Systems in China
With the increasing popularity of fresh-air filtration systems, the methods of determining the outdoor PM2.5 design concentration have become more important. However, the monitoring of atmospheric fine particles in China started relatively late, and there are relatively few cities with complete data, with obvious regional differences, which led to many problems in the selection of air filters for fresh-air filtration systems. In this paper, three methods of determining outdoor PM2.5 design concentration were analyzed using the daily average concentration of PM2.5 in 31 provincial capital cities from 2016 to 2020. Six typical cities in different regions were also taken as examples. The advantages and disadvantages of the three existing statistical methods were compared and analyzed, as well as the corresponding differences in the selection of outdoor PM2.5 concentration value on the filter systems. The results showed that the method of mathematical induction was more accurate and reasonable for the calculation of outdoor PM2.5 design concentrations. The local outdoor PM2.5 design concentration could be quickly calculated using the recommended coefficient K and annual average PM2.5 concentration of the region, especially for small and medium-sized cities without monitoring data. However, the recommended coefficient K should be provided based on the specific region, and should be divided into values for strict conditions and normal conditions during use. This would provide a simple and effective way to select the correct air filters for practical engineering.