Hongrui Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hongrui Chen has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Lichun Xiao
Hebei Key Laboratory of Heavy Metal Deep-Remediation in Water And Resource Reuse, School of Environmental and Chemical Engineering, Yanshan University, Qinhuangdao 066004, China
3 shared publications - Yingying Han
Hebei Key Laboratory of Heavy Metal Deep-Remediation in Water And Resource Reuse, School of Environmental and Chemical Engineering, Yanshan University, Qinhuangdao 066004, China
3 shared publications - Hengtian Li
Hebei Key Laboratory of Heavy Metal Deep-Remediation in Water And Resource Reuse, School of Environmental and Chemical Engineering, Yanshan University, Qinhuangdao 066004, China
2 shared publications - Xiaoyu Zhai
Hebei Key Laboratory of Heavy Metal Deep-Remediation in Water And Resource Reuse, School of Environmental and Chemical Engineering, Yanshan University, Qinhuangdao 066004, China
2 shared publications - Shuting Wang
Hebei Key Laboratory of Heavy Metal Deep-Remediation in Water And Resource Reuse, School of Environmental and Chemical Engineering, Yanshan University, Qinhuangdao 066004, China
1 shared publication
Latest Publications
- Open Access
Synergistic Humidification and Chemical Agglomeration to Improve Capturing the Fine Particulate Matter by Electrostatic Precipitator
The wet electrostatic precipitator (WESP) overcomes the shortcomings of traditional electrostatic precipitators, such as dust re-entrainment and back corona. It can effectively remove high-specific-resistivity dust, with a good removal effect on PM2.5. It is proposed to adopt chemical agglomeration and humidification agglomeration technology in the wet electrostatic precipitators to achieve ultra-low dust emissions from coal-fired power plants. The results show that the addition of chemical agglomerates, surfactants, and water vapor all affect the dust diameter of coal-fired power plants. After adding sesbania gum (SG), the D50 of dust particles increases from 28.29 μm to 48.22 μm. And the D50 of dust particles is 36.46 μm when spraying 3.6 kg/h water vapor only. With the cooperation of chemical agglomeration agents and water vapor, the dust agglomeration effect and removal efficiency can be further improved. When 10 mg/L SG is synergistically combined with 2.9 kg/h water vapor, the D50 is 64.75 μm, and the dust removal efficiency reaches 97.88%. On this basis, by adding 5 mg/L of Hexadecyltrimethylammonium bromide (CTAB), the D50 is 83.06 μm, and the dust removal efficiency increases to 98.62%. The synergistic effect of chemical agglomeration and humidification agglomeration promotes the aggregation of dust from coal-fired power plants. It can improve the removal efficiency of WESP for fine particulate matter but has little impact on the operation of existing equipment. The synergistic effects of multiple agglomeration technologies are also the direction for future research on the removal efficiency of fine particulate matter.
Open AccessSynergistic Humidification and Chemical Agglomeration to Improve Capturing the Fine Particulate Matter by Electrostatic Precipitator
The wet electrostatic precipitator (WESP) overcomes the shortcomings of traditional electrostatic precipitators, such as dust re-entrainment and back corona. It can effectively remove high-specific-resistivity dust, with a good removal effect on PM2.5. It is proposed to adopt chemical agglomeration and humidification agglomeration technology in the wet electrostatic precipitators to achieve ultra-low dust emissions from coal-fired power plants. The results show that the addition of chemical agglomerates, surfactants, and water vapor all affect the dust diameter of coal-fired power plants. After adding sesbania gum (SG), the D50 of dust particles increases from 28.29 μm to 48.22 μm. And the D50 of dust particles is 36.46 μm when spraying 3.6 kg/h water vapor only. With the cooperation of chemical agglomeration agents and water vapor, the dust agglomeration effect and removal efficiency can be further improved. When 10 mg/L SG is synergistically combined with 2.9 kg/h water vapor, the D50 is 64.75 μm, and the dust removal efficiency reaches 97.88%. On this basis, by adding 5 mg/L of Hexadecyltrimethylammonium bromide (CTAB), the D50 is 83.06 μm, and the dust removal efficiency increases to 98.62%. The synergistic effect of chemical agglomeration and humidification agglomeration promotes the aggregation of dust from coal-fired power plants. It can improve the removal efficiency of WESP for fine particulate matter but has little impact on the operation of existing equipment. The synergistic effects of multiple agglomeration technologies are also the direction for future research on the removal efficiency of fine particulate matter.
- Open Access
Experimental Study on Humidification Coagulation and Removal of Fine Particles Using an Electrostatic Precipitator
A wet electrostatic precipitator (WESP) has much higher capture rate for fine particulate matter, PM2.5, than a traditional dry type electrostatic precipitator does. In order to make full use of existing dust removal equipment and reduce the emissions of smoke and dust to zero, a combination of chemical coagulation and humidification coagulation is proposed using a WESP. The results show that the addition of chemical coagulant can promote the coagulation of coal-fired dust particles. After the addition of pectin (PG), the median diameter of dust particles increases from 28.19 μm to 45.28 μm. Water vapor humidification can promote the coagulation of dust particles. When the water vapor injection rate increases from 0 kg/h to 3.2 kg/h, the median diameter of dust particles increases from 28.19 μm to 36.45 μm. The synergistic effect of the coagulant and water vapor can enhance the chemical coagulation effect; when 1.0 × 10−2 g/L PG and 3.2 kg/h water vapor synergize, the collection efficiency reaches 98.17%, and when 1.0 × 10−2 g/L polyacrylamide (PAM) and 3.2 kg/h water vapor synergize, the collection efficiency reaches 96.68%. Both chemical coagulation and water vapor humidification can promote the condensation of coal dust, which is beneficial to improve the efficient capture of fine particles using WESP.
Open AccessExperimental Study on Humidification Coagulation and Removal of Fine Particles Using an Electrostatic Precipitator
A wet electrostatic precipitator (WESP) has much higher capture rate for fine particulate matter, PM2.5, than a traditional dry type electrostatic precipitator does. In order to make full use of existing dust removal equipment and reduce the emissions of smoke and dust to zero, a combination of chemical coagulation and humidification coagulation is proposed using a WESP. The results show that the addition of chemical coagulant can promote the coagulation of coal-fired dust particles. After the addition of pectin (PG), the median diameter of dust particles increases from 28.19 μm to 45.28 μm. Water vapor humidification can promote the coagulation of dust particles. When the water vapor injection rate increases from 0 kg/h to 3.2 kg/h, the median diameter of dust particles increases from 28.19 μm to 36.45 μm. The synergistic effect of the coagulant and water vapor can enhance the chemical coagulation effect; when 1.0 × 10−2 g/L PG and 3.2 kg/h water vapor synergize, the collection efficiency reaches 98.17%, and when 1.0 × 10−2 g/L polyacrylamide (PAM) and 3.2 kg/h water vapor synergize, the collection efficiency reaches 96.68%. Both chemical coagulation and water vapor humidification can promote the condensation of coal dust, which is beneficial to improve the efficient capture of fine particles using WESP.
- Open Access
Chemical Agglomeration to Enhance Blast Furnace Dust Capture Efficiency in Wet Electrostatic Precipitators
Wet electrostatic precipitators (WESPs) are increasingly used in iron and steel plants and coal-fired power plants due to their higher efficiency at capturing fine particles than conventional dry-type precipitators. In order to achieve ultra-pure purification of dust in steel plant gas, we propose an improved method that involves adding a chemical coagulant and a surfactant to a WESP. The effects of the type and concentration of chemical coagulant and surfactant on the agglomeration effect and dust removal efficiency of blast furnace dust were investigated. The results show that the addition of a chemical coagulant could promote the agglomeration of blast furnace dust particles, and the D50 of dust particles increased from 5.8 to 15.0 μm after the addition of xanthan gum (XTG). The best increase in the blast furnace’s dust particle removal occurred at a concentration of 10 mg/L of XTG, and the dust removal efficiency reached 97.59%. The surfactant dodecyl trimethyl ammonium chloride (DTAC) improved the dust removal efficiency of blast furnace dust when added alone. The dust removal efficiency reached 97.82% when 10 mg/L of XTG and 9 mg/L of DTAC were added synergistically. The addition of a chemical coagulant and surfactant promoted the agglomeration of blast furnace dust and enhanced the dust capture effect of a WESP. We thus demonstrated that we can improve the efficiency of WESP in the future via chemical coagulation. The authors will further study the effect of multi-factor synergistic coupling on the chemical coagulation method in WESPs.
Open AccessChemical Agglomeration to Enhance Blast Furnace Dust Capture Efficiency in Wet Electrostatic Precipitators
Wet electrostatic precipitators (WESPs) are increasingly used in iron and steel plants and coal-fired power plants due to their higher efficiency at capturing fine particles than conventional dry-type precipitators. In order to achieve ultra-pure purification of dust in steel plant gas, we propose an improved method that involves adding a chemical coagulant and a surfactant to a WESP. The effects of the type and concentration of chemical coagulant and surfactant on the agglomeration effect and dust removal efficiency of blast furnace dust were investigated. The results show that the addition of a chemical coagulant could promote the agglomeration of blast furnace dust particles, and the D50 of dust particles increased from 5.8 to 15.0 μm after the addition of xanthan gum (XTG). The best increase in the blast furnace’s dust particle removal occurred at a concentration of 10 mg/L of XTG, and the dust removal efficiency reached 97.59%. The surfactant dodecyl trimethyl ammonium chloride (DTAC) improved the dust removal efficiency of blast furnace dust when added alone. The dust removal efficiency reached 97.82% when 10 mg/L of XTG and 9 mg/L of DTAC were added synergistically. The addition of a chemical coagulant and surfactant promoted the agglomeration of blast furnace dust and enhanced the dust capture effect of a WESP. We thus demonstrated that we can improve the efficiency of WESP in the future via chemical coagulation. The authors will further study the effect of multi-factor synergistic coupling on the chemical coagulation method in WESPs.