Elisa Venturi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Elisa Venturi has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Fabian Ochs
University of Innsbruck
9 shared publications - Georgios Dermentzis
University of Innsbruck
5 shared publications - Mara Magni
University of Innsbruck
5 shared publications - Samuel Breuss
University of Innsbruck
3 shared publications Georgios Dermentzis
Universität Innsbruck
2 shared publicationsMara Magni
Affiliation Unit of Energy Efficient Building, Universität Innsbruck, Innsbruck, Austria
2 shared publications
Latest Publications
- Open Access
- 22 May 2026
- Published by TIB Open Publishing in International Sustainable Energy Conference - Proceedings
- Vol. 2
Towards Positive Energy Districts
A Positive Energy District (PED) envisions supporting the urban energy transition, requiring improved technologies and holistic planning processes. The “Campagne” project in Innsbruck serves as a demonstrator on the path towards PEDs. Multiple heat pump (HP) system topologies can be considered, ranging from fully central HP systems at district scale to semi-central solutions with a central low-temperature HP and booster HPs at building or flat level, as well as decentral building-wise HPs and mixed concepts such as central for space heating and decentral for domestic hot water. The optimal HP system topology depends on local boundary conditions, with decentral HPs generally outperforming central ones. Semi-central booster configurations achieve good energy performance but remain economically challenging, highlighting the need for decision-support workflows that enable cost-optimal design and serve as the basis for a future integral planning approach.
- 22 May 2026
- Published by TIB Open Publishing in International Sustainable Energy Conference - Proceedings
- Vol. 2
Open AccessTowards Positive Energy Districts
A Positive Energy District (PED) envisions supporting the urban energy transition, requiring improved technologies and holistic planning processes. The “Campagne” project in Innsbruck serves as a demonstrator on the path towards PEDs. Multiple heat pump (HP) system topologies can be considered, ranging from fully central HP systems at district scale to semi-central solutions with a central low-temperature HP and booster HPs at building or flat level, as well as decentral building-wise HPs and mixed concepts such as central for space heating and decentral for domestic hot water. The optimal HP system topology depends on local boundary conditions, with decentral HPs generally outperforming central ones. Semi-central booster configurations achieve good energy performance but remain economically challenging, highlighting the need for decision-support workflows that enable cost-optimal design and serve as the basis for a future integral planning approach.
- 1 April 2026
- Published by Springer Nature
- p. 815-824
Improving Heat Pump System Performance with Fan-Convectors in Multi-Apartment Buildings
- 1 April 2026
- Published by Springer Nature
- p. 815-824
Improving Heat Pump System Performance with Fan-Convectors in Multi-Apartment Buildings
- Open Access
- 16 March 2026
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 19 (6) , 1145-1179
Complex hydronic systems in multi-apartment buildings: modelling approaches and dynamic simulations
BCBoundary ConditionsDHDistrict HeatingDHWDomestic Hot WaterHPHeat pumpHVACHeating, Ventilation and Air ConditioningKPIKey Performances IndicatorMABMulti-Apartment BuildingMTZMulti-Thermal ZoneNSBN...
- 16 March 2026
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 19 (6) , 1145-1179
Open AccessComplex hydronic systems in multi-apartment buildings: modelling approaches and dynamic simulations
BCBoundary ConditionsDHDistrict HeatingDHWDomestic Hot WaterHPHeat pumpHVACHeating, Ventilation and Air ConditioningKPIKey Performances IndicatorMABMulti-Apartment BuildingMTZMulti-Thermal ZoneNSBN...
- Open Access
- 4 March 2026
- Published by Public Library of Science (PLoS) in PLOS Climate
- Vol. 5 (3) , e0000842
Energy scenarios for the decarbonisation of the building stock in the context of the energy system transformation
Decarbonising the building stock relies on the strategies of efficiency, sufficiency and consistency. Building stock energy scenarios (BSES) help evaluate the effect of these measures by modelling the existing building stock and using appropriate inputs, but must also account for boundary conditions, such as the structure of the energy system. In renewable energy (RE)-based systems, high summer generation contrasts with winter building stock demand, creating a seasonal gap. This study presents two BSES for Austria: a BAU scenario with standard decarbonisation measures (HVAC change and renovation rates) and a BEST scenario with more ambitious rates. Three energy system configurations are considered: (A) a demand-independent energy system based on current data of the Austrian electricity generation, (B) a RE-based generation system in terms of net-annual balance with the energy demand but connected with surrounding countries, and (C) an autarkic RE-based system with seasonal storage (based on green hydrogen). The key performance indicators (KPIs) used to assess the decarbonisation of a system are the equivalent CO 2 emissions, the load cover factor (LCF) and the required PV generation to reach energy autarky. The results show that the assumption of the energy system structure has a strong impact on the effectiveness of different measures. Hence, the choice of the KPIs is sensitive with respect to the boundary conditions. A building stock within a RE-based domestic energy system relying on energy imports to cover the winter gap cannot be considered fully decarbonised, if the import electricity mix is not known. On the other hand, an autarkic system is not feasible if the domestic demand exceeds the RE potential. The RE mix of the generation system, along with the load characteristics, has an impact on the winter gap magnitude, consequently influencing the energy imports or the seasonal storage requirements.
- 4 March 2026
- Published by Public Library of Science (PLoS) in PLOS Climate
- Vol. 5 (3) , e0000842
Open AccessEnergy scenarios for the decarbonisation of the building stock in the context of the energy system transformation
Decarbonising the building stock relies on the strategies of efficiency, sufficiency and consistency. Building stock energy scenarios (BSES) help evaluate the effect of these measures by modelling the existing building stock and using appropriate inputs, but must also account for boundary conditions, such as the structure of the energy system. In renewable energy (RE)-based systems, high summer generation contrasts with winter building stock demand, creating a seasonal gap. This study presents two BSES for Austria: a BAU scenario with standard decarbonisation measures (HVAC change and renovation rates) and a BEST scenario with more ambitious rates. Three energy system configurations are considered: (A) a demand-independent energy system based on current data of the Austrian electricity generation, (B) a RE-based generation system in terms of net-annual balance with the energy demand but connected with surrounding countries, and (C) an autarkic RE-based system with seasonal storage (based on green hydrogen). The key performance indicators (KPIs) used to assess the decarbonisation of a system are the equivalent CO 2 emissions, the load cover factor (LCF) and the required PV generation to reach energy autarky. The results show that the assumption of the energy system structure has a strong impact on the effectiveness of different measures. Hence, the choice of the KPIs is sensitive with respect to the boundary conditions. A building stock within a RE-based domestic energy system relying on energy imports to cover the winter gap cannot be considered fully decarbonised, if the import electricity mix is not known. On the other hand, an autarkic system is not feasible if the domestic demand exceeds the RE potential. The RE mix of the generation system, along with the load characteristics, has an impact on the winter gap magnitude, consequently influencing the energy imports or the seasonal storage requirements.
- 23 November 2025
- Published by Springer Nature
- p. 998-1007
Optimization of a Multi-apartment HVAC System Using Simulation and Monitoring Data
- 23 November 2025
- Published by Springer Nature
- p. 998-1007
Optimization of a Multi-apartment HVAC System Using Simulation and Monitoring Data
- 23 November 2025
- Published by Springer Nature
- p. 443-452
Monitoring-Based Analysis of Decentralized Domestic Hot Water Preparation in Large Multi-Family Buildings
- 23 November 2025
- Published by Springer Nature
- p. 443-452
Monitoring-Based Analysis of Decentralized Domestic Hot Water Preparation in Large Multi-Family Buildings
- 6 December 2024
- Published by Springer Nature
- p. 11-17
Towards Digital Twin - Holistic Planning of Thermal Renovations with Heat Pumps in Multi-apartment Buildings
- 6 December 2024
- Published by Springer Nature
- p. 11-17
Towards Digital Twin - Holistic Planning of Thermal Renovations with Heat Pumps in Multi-apartment Buildings
- Open Access
- 30 April 2024
- Published by TIB Open Publishing in International Sustainable Energy Conference - Proceedings
- Vol. 1
Techno-Economic Analysis of the Heating System Robustness
A techno-economic analysis of different heating systems of a multi-apartment building is performed. The final energy savings and the economic benefit under different boundary conditions are investigated for a Passive House that has been realized and monitored in Innsbruck, Austria. Eight different system combinations are considered, varying the heat generation (direct electric (as-built), air/water heat pump (HP) and groundwater HP) as well as the size of the photovoltaic (PV) system. The systems are investigated with a building model with two different parameterizations: the pre-design stage and the model adapted to the monitored boundary conditions (BC: climate and user behaviour) and monitored energy consumption. The monitoring of the first two years of operation revealed a significantly higher space heating demand (29 kWh/(m2a) compared to 8 kWh/(m2a)). The most robust system (i.e. the system that performs best independent of the BC) for primary energy optimization is identified as an air-source heat pump with a 32 kWp photovoltaic system. This system also allows economic savings in case of high heating demand (adapted building model) and slightly higher costs in case of low heating demand (pre-design model). The groundwater-source HP is cost-effective only in scenarios with high heating demand due to significant investment and installation costs. Monthly primary energy factors are used to account for seasonal effects of the energy demand, providing an assessment of system efficiency that accounts for the so-called winter gap.
- 30 April 2024
- Published by TIB Open Publishing in International Sustainable Energy Conference - Proceedings
- Vol. 1
Open AccessTechno-Economic Analysis of the Heating System Robustness
A techno-economic analysis of different heating systems of a multi-apartment building is performed. The final energy savings and the economic benefit under different boundary conditions are investigated for a Passive House that has been realized and monitored in Innsbruck, Austria. Eight different system combinations are considered, varying the heat generation (direct electric (as-built), air/water heat pump (HP) and groundwater HP) as well as the size of the photovoltaic (PV) system. The systems are investigated with a building model with two different parameterizations: the pre-design stage and the model adapted to the monitored boundary conditions (BC: climate and user behaviour) and monitored energy consumption. The monitoring of the first two years of operation revealed a significantly higher space heating demand (29 kWh/(m2a) compared to 8 kWh/(m2a)). The most robust system (i.e. the system that performs best independent of the BC) for primary energy optimization is identified as an air-source heat pump with a 32 kWp photovoltaic system. This system also allows economic savings in case of high heating demand (adapted building model) and slightly higher costs in case of low heating demand (pre-design model). The groundwater-source HP is cost-effective only in scenarios with high heating demand due to significant investment and installation costs. Monthly primary energy factors are used to account for seasonal effects of the energy demand, providing an assessment of system efficiency that accounts for the so-called winter gap.
- Open Access
- 25 April 2024
- Published by TIB Open Publishing in International Sustainable Energy Conference - Proceedings
- Vol. 1
Towards Positive Energy Districts
Positive energy districts (PEDs) are a vision to enable and foster the energy transition in the building sector. The integration of heat pumps (HP) in buildings and districts to achieve a net positive energy balance is crucial. The efficiency of the electric and thermal energy system of districts can be improved with the use of HPs. This refers to both, the upgrade of waste heat and benefiting from simultaneous use and generation of energy in buildings at different temperature levels (space heating, DHW, space cooling/dehumidification) and includes self-consumption of on-site renewable electricity generation. Using the example of the new district Innsbruck Campagne, HP integration options as well as photovoltaic (PV) integration potentials are evaluated with respect to reaching a positive energy balance. Both simulation results as well as monitoring results are presented. The importance of very high building efficiency standards as well as well-designed and dimensioned systems to achieve a positive energy balance and to reduce the so-called winter gap is highlighted.
- 25 April 2024
- Published by TIB Open Publishing in International Sustainable Energy Conference - Proceedings
- Vol. 1
Open AccessTowards Positive Energy Districts
Positive energy districts (PEDs) are a vision to enable and foster the energy transition in the building sector. The integration of heat pumps (HP) in buildings and districts to achieve a net positive energy balance is crucial. The efficiency of the electric and thermal energy system of districts can be improved with the use of HPs. This refers to both, the upgrade of waste heat and benefiting from simultaneous use and generation of energy in buildings at different temperature levels (space heating, DHW, space cooling/dehumidification) and includes self-consumption of on-site renewable electricity generation. Using the example of the new district Innsbruck Campagne, HP integration options as well as photovoltaic (PV) integration potentials are evaluated with respect to reaching a positive energy balance. Both simulation results as well as monitoring results are presented. The importance of very high building efficiency standards as well as well-designed and dimensioned systems to achieve a positive energy balance and to reduce the so-called winter gap is highlighted.
- Open Access
- 9 December 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 64
Identifying the influence of user behaviour on building energy consumption based on model-based analysis of in-situ monitoring data
- 9 December 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 64
Open AccessIdentifying the influence of user behaviour on building energy consumption based on model-based analysis of in-situ monitoring data