CWChristian Wiede

Christian Wiede

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Christian Wiede has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Analysis of the frequency-dependent sensitivity distribution for lower forearm impedance plethysmography

    by Niko Strotmann, Christian Wiede, Roman Kusche, Karsten Seidl

    Objective . The assessment of hemodynamic parameters plays an important role for the diagnosis and detection of cardiovascular diseases. One of the promising techniques for the non-invasive and continuous monitoring of arterial hemodynamics is the impedance plethysmography (IPG), which aims to measure the pulsatile volume change of superficial arteries. Crucial for the success of an IPG measurement is the selection of a setup that effectively targets the artery. Approach . This work analyzes the influence of the injection frequency alteration on the sensitivity distribution of an IPG measurement and the sensitivity towards the radial artery. The analysis is performed both in simulation and using study data obtained from 41 participants. The simulation consists of a finite element model representing the lower forearm and a fixed IPG setup, in which the sensitivity distribution is analyzed for different excitation frequencies between 3 kHz and 100 kHz. To allow for comparison, the IPG study utilizes the same five excitation frequencies between 3 kHz and 100 kHz. Main results . The results of the finite element simulation show that increasing excitation frequency shifts the region of large sensitivity away from the artery and especially towards deeper muscle tissue layers. The analysis of the study data supports this hypothesis by demonstrating that lower-frequency excitation yields larger relative pulsatile changes than larger excitation frequencies, thus indicating a larger sensitivity towards the pulsatile artery. Significance . The results of this paper show, that injection frequency directly affects the sensitivity regions. Analysis of the finite element method and study results indicate that the largest sensitivity towards the radial artery occurs at the smallest injection frequency. Thus, comparison of IPG measurements performed at different excitation frequencies should be interpreted carefully, comparability between individual measurements may be limited.

  • Open Access

    Feature-Based Detection and Classification of Sleep Apnea and Hypopnea Using Multispectral Imaging

    by Belmin Alić, Christian Wiede, Reinhard Viga, Karsten Seidl

    Sleep apnea syndrome (SAS) is a sleep-related breathing disorder characterized by repetitive breathing interruptions during sleep, resulting in daytime drowsiness, concentration difficulties, and increased risk of cardiovascular diseases. SAS is diagnosed in specialized sleep laboratories via polysomnography (PSG). PSG involves a high number of contact-based sensors, and it may cause patient discomfort and bias in measurement results. Therefore, contactless alternatives to PSG are a promising way to overcome these issues. This work introduces a novel featurebased method for detecting and classifying apneic events in terms of event amplitude (apneas and hypopneas) and event source (obstructive and central) by using multispectral imaging in the near-infrared (NIR) and far-infrared (FIR) spectra. In the NIR spectrum, remote photoplethysmography signals at 780 and 940 nm are extracted, while in the FIR spectrum, a respiratory airflow signal is extracted. The method is based on the extraction of explainable and medically significant features and the fusion of multiple data modalities (multispectral images, demographic patient data, interspectral correlation analysis, and time-series analysis). The classification accuracy between normal breathing, hypopneas, and apneas is 99.5%, while the differentiation between obstructive and central apneas achieves an accuracy of 98.8%. The estimations of the apnea-hypopnea index (AHI), obstructive apnea index (oAI), and central apnea index (cAI) result in a Pearson correlation of 0.9981, 0.9989, and 0.9950 respectively. A correct SAS stage prediction for 19 symptomatic patients in our dataset is accomplished. The results show that this method may be used as a PSG substitute for apnea and hypopnea detection and classification.


  • Open Access

    MSNR: A Multistage Noise Reduction Method on Point Cloud+

    by Gongbo Chen, Santosh Kumar Kasam, Christian Wiede

    In autonomous driving, direct time-of-flight (d-ToF) light detection and ranging (LiDAR) is one of the most emerging techniques due to its high depth resolution and detection ability in specific environments. Tasks such as object recognition and scene segmentation use distance information in LiDAR point clouds as ground-truth to improve performance. However, in harsh measurement environments, the amount of noise in a LiDAR point cloud increases significantly. In this case, an algorithm using LiDAR data will be misleading, resulting in performance degradation. Although many noise filtering algorithms at point cloud-level were proposed, their effectiveness is limited, as traditional point clouds contain only distance information. In this paper, a method with multi-stage noise reduction (MSNR) is proposed. It takes point cloud+ as input. Comparing to the method using conventional point cloud as input, MSNR improves accuracy by 29.50% under high background light.


  • Open Access

    AIfES: A Next-Generation Edge AI Framework

    by Lars Wulfert, Johannes Kühnel, Lukas Krupp, Justus Viga, Christian Wiede, Pierre Gembaczka, Anton Grabmaier

    Edge Artificial Intelligence (AI) relies on the integration of Machine Learning (ML) into even the smallest embedded devices, thus enabling local intelligence in real-world applications, e.g. for image or speech processing. Traditional Edge AI frameworks lack important aspects required to keep up with recent and upcoming ML innovations. These aspects include low flexibility concerning the target hardware and limited support for custom hardware accelerator integration. Artificial Intelligence for Embedded Systems Framework (AIfES) has the goal to overcome these challenges faced by traditional edge AI frameworks. In this paper, we give a detailed overview of the architecture of AIfES and the applied design principles. Finally, we compare AIfES with TensorFlow Lite for Microcontrollers (TFLM) on an ARM Cortex-M4-based System-on-Chip (SoC) using fully connected neural networks (FCNNs) and convolutional neural networks (CNNs). AIfES outperforms TFLM in both execution time and memory consumption for the FCNNs. Additionally, using AIfES reduces memory consumption by up to 54 % when using CNNs. Furthermore, we show the performance of AIfES during the training of FCNN as well as CNN and demonstrate the feasibility of training a CNN on a resource-constrained device with a memory usage of slightly more than 100 kB of RAM.


  • Open Access

    Adaptive Decentralized Federated Gossip Learning for Resource-Constrained IoT Devices

    by Lars Wulfert, Navidreza Asadi, Wen-Yu Chung, Christian Wiede, Anton Grabmaier

    With the increasing number of internet of things devices and the ability to enhance data privacy using federated learning (FL), there is a growing interest in exploring FL on resource-constrained devices. Centralized FL uses a central server (CS), which can lead to privacy issues, poor scalability, high communication costs. To address these challenges, decentralized federated learning (DFL) has been proposed, which allows FL without a CS. To keep the communication cost low in DFL the gossip protocol can be used, where random clients exchange their models. However, this may result in slower convergence and lower accuracy. To overcome these limitations, we present AdaStair, a static method, and AdaLoss, a dynamic method that adaptively adjusts the learning rate of each client in a decentralized manner. Additionally, we modify the communication protocol of GossipFL and add quantization to further reduce the communication cost. We demonstrate the robustness of these methods in both simulations and real-world evaluations using microcontroller units in a partial WiFi ad-hoc mesh network. Our experimental results show that AdaStair and AdaLoss can improve accuracy up to 19% and reduce communication costs by up to 57% using a quantization scheme compared to a segmented gossip method.


  • Open Access

    Explainable Remaining Tool Life Prediction for Individualized Production Using Automated Machine Learning

    by Lukas Krupp, Christian Wiede, Joachim Friedhoff, Anton Grabmaier

    The increasing demand for customized products is a core driver of novel automation concepts in Industry 4.0. For the case of machining complex free-form workpieces, e.g., in die making and mold making, individualized manufacturing is already the industrial practice. The varying process conditions and demanding machining processes lead to a high relevance of machining domain experts and a low degree of manufacturing flow automation. In order to increase the degree of automation, online process monitoring and the prediction of the quality-related remaining cutting tool life is indispensable. However, the varying process conditions complicate this as the correlation between the sensor signals and tool condition is not directly apparent. Furthermore, machine learning (ML) knowledge is limited on the shop floor, preventing a manual adaption of the models to changing conditions. Therefore, this paper introduces a new method for remaining tool life prediction in individualized production using automated machine learning (AutoML). The method enables the incorporation of machining expert knowledge via the model inputs and outputs. It automatically creates end-to-end ML pipelines based on optimized ensembles of regression and forecasting models. An explainability algorithm visualizes the relevance of the model inputs for the decision making. The method is analyzed and compared to a manual state-of-the-art approach for series production in a comprehensive evaluation using a new milling dataset. The dataset represents gradual tool wear under changing workpieces and process parameters. Our AutoML method outperforms the state-of-the-art approach and the evaluation indicates that a transfer of methods designed for series production to variable process conditions is not easily possible. Overall, the new method optimizes individualized production economically and in terms of resources. Machining experts with limited ML knowledge can leverage their domain knowledge to develop, validate and adapt tool life models.


  • Open Access

    Current methods for contactless optical patient diagnosis: a systematic review

    by Belmin Alić, Tim Zauber, Christian Wiede, Karsten Seidl

    Many countries around the world face a shortage of medical personnel, leading to work overload or even burnout. This calls for political and scientific solutions to relieve the medical personnel. The measurement of vital signs in hospitals is still predominately carried out manually with traditional contact-based methods, taking over a substantial share of the medical personnel’s workload. The introduction of contactless methods for vital sign monitoring (e.g., with a camera) has great potential to relieve the medical personnel. This systematic review’s objective is to analyze the state of the art in the field of contactless optical patient diagnosis. This review distinguishes itself from already existing reviews by considering studies that do not only propose the contactless measurement of vital signs but also include an automatic diagnosis of the patient’s condition. This means that the included studies incorporate the physician’s reasoning and evaluation of vital signs into their algorithms, allowing an automated patient diagnosis. The literature screening of two independent reviewers resulted in a total of five eligible studies. The highest number of studies (three) introduce methods for the risk assessment of infectious diseases, one study introduces a method for the risk assessment of cardiovascular diseases, and one study introduces a method for the diagnosis of obstructive sleep apnea. Overall, high heterogeneity in relevant study parameters is reported among the included studies. The low number of included studies indicates a large research gap and emphasizes the demand for further research on this emerging topic.


  • Open Access

    Depth-Based Measurement of Respiratory Volumes: A Review

    by Felix Wichum, Christian Wiede, Karsten Seidl

    Depth-based plethysmography (DPG) for the measurement of respiratory parameters is a mobile and cost-effective alternative to spirometry and body plethysmography. In addition, natural breathing can be measured without a mouthpiece, and breathing mechanics can be visualized. This paper aims at showing further improvements for DPG by analyzing recent developments regarding the individual components of a DPG measurement. Starting from the advantages and application scenarios, measurement scenarios and recording devices, selection algorithms and location of a region of interest (ROI) on the upper body, signal processing steps, models for error minimization with a reference measurement device, and final evaluation procedures are presented and discussed. It is shown that ROI selection has an impact on signal quality. Adaptive methods and dynamic referencing of body points to select the ROI can allow more accurate placement and thus lead to better signal quality. Multiple different ROIs can be used to assess breathing mechanics and distinguish patient groups. Signal acquisition can be performed quickly using arithmetic calculations and is not inferior to complex 3D reconstruction algorithms. It is shown that linear models provide a good approximation of the signal. However, further dependencies, such as personal characteristics, may lead to non-linear models in the future. Finally, it is pointed out to focus developments with respect to single-camera systems and to focus on independence from an individual calibration in the evaluation.


  • Open Access

    A Calibration-free Blood Pressure Measurement on a Scale: Concept and Challenges

    by Christian Wiede, Carolin Wuerich, Anton Grabmaier

  • Open Access

    07-1345-C17

    by Christian Wiede, Karsten Seidl, Uwe Tronnier

    Article 07-1345-C17 was published on September 1, 2021 in the journal Biomedical Engineering / Biomedizinische Technik (volume 66, issue s1).