Zhiqiang Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhiqiang Zhou has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Liang Dong
3 shared publicationsRan Jiao
2 shared publications- Ran Jiao
Guangzhou Municipal Group Design Institute Co., Ltd., Guangzhou 510095, China
2 shared publications - Huijian Hu
Guangdong Key Laboratory of Animal Conservation and Resource Utilization, Guangdong Public Laboratory of Wild Animal Conservation and Utilization, Institute of Zoology, Guangdong Academy of Sciences, Guangzhou 510275, China
1 shared publication Li Li
1 shared publication- Liang Dong
School of Architecture, Huaqiao University, Xiamen 361021, China
1 shared publication
Latest Publications
- Open Access
- 29 September 2026
- Published by Taylor & Francis in Journal of Asian Architecture and Building Engineering
- p. 1-21
How does building height optimize the summer thermal environment in shaded zones? A microscale simulation study in a hot-humid climate
1. Under the dual drivers of global climate change and rapid urbanization, urban residents are facing increasingly severe thermal environmental challenges. The intensification of the urban heat isl...
- 29 September 2026
- Published by Taylor & Francis in Journal of Asian Architecture and Building Engineering
- p. 1-21
Open AccessHow does building height optimize the summer thermal environment in shaded zones? A microscale simulation study in a hot-humid climate
1. Under the dual drivers of global climate change and rapid urbanization, urban residents are facing increasingly severe thermal environmental challenges. The intensification of the urban heat isl...
- 8 November 2025
- Published by Elsevier in Building and Environment
- Vol. 288
Effects of building shading on outdoor adaptive thermal comfort and the development of predictive models
- 8 November 2025
- Published by Elsevier in Building and Environment
- Vol. 288
Effects of building shading on outdoor adaptive thermal comfort and the development of predictive models
- Open Access
- 20 May 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (10) , 4689
Impact of the Pilotis Ratio on the Summer Wind and Thermal Environment in Shaded Areas of Enclosed Courtyards in Hot and Humid Regions
Enclosed courtyards with partially ground floor pilotis represent a prevalent architectural spatial configuration in hot-humid regions, where the shaded outdoor areas serve as frequently utilized spaces for heat avoidance and rest. This study employed a combined approach of ENVI-met simulations and field measurements to investigate the wind and thermal environment in the shaded areas of courtyards under 40 different pilotis width configurations. The Comfortable Wind Zone Ratio (CWZR) and Physiological Equivalent Temperature (PET) were used as primary evaluation metrics to systematically investigate the influence of varying inlet/outlet width ratios in building pilotis on the wind-thermal environment within courtyard-shaded zones. The results demonstrate that: (1) Under a fixed outlet size, enlarging the inlet significantly enhances the CWZR in the shaded area, with a 28.66% difference observed between inlet sizes of L/4 and L. In contrast, under a fixed inlet size, expanding the outlet has a negligible effect on CWZR improvement. (2) Under a fixed outlet size, increasing the inlet width substantially reduces PET in the shaded zone, showing a 2.46 °C difference between inlet sizes of L/4 and L. Conversely, under a fixed inlet size, widening the outlet has a minimal impact on PET reduction. (3) A negative correlation exists between CWZR and PET in the shaded area, indicating that an increase in CWZR leads to a decrease in PET values. The findings provide bioclimatically quantified guidelines for the spatial design of courtyard pilotis in hot-humid regions, offering practical insights for optimizing thermal comfort in shaded outdoor environments.
- 20 May 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (10) , 4689
Open AccessImpact of the Pilotis Ratio on the Summer Wind and Thermal Environment in Shaded Areas of Enclosed Courtyards in Hot and Humid Regions
Enclosed courtyards with partially ground floor pilotis represent a prevalent architectural spatial configuration in hot-humid regions, where the shaded outdoor areas serve as frequently utilized spaces for heat avoidance and rest. This study employed a combined approach of ENVI-met simulations and field measurements to investigate the wind and thermal environment in the shaded areas of courtyards under 40 different pilotis width configurations. The Comfortable Wind Zone Ratio (CWZR) and Physiological Equivalent Temperature (PET) were used as primary evaluation metrics to systematically investigate the influence of varying inlet/outlet width ratios in building pilotis on the wind-thermal environment within courtyard-shaded zones. The results demonstrate that: (1) Under a fixed outlet size, enlarging the inlet significantly enhances the CWZR in the shaded area, with a 28.66% difference observed between inlet sizes of L/4 and L. In contrast, under a fixed inlet size, expanding the outlet has a negligible effect on CWZR improvement. (2) Under a fixed outlet size, increasing the inlet width substantially reduces PET in the shaded zone, showing a 2.46 °C difference between inlet sizes of L/4 and L. Conversely, under a fixed inlet size, widening the outlet has a minimal impact on PET reduction. (3) A negative correlation exists between CWZR and PET in the shaded area, indicating that an increase in CWZR leads to a decrease in PET values. The findings provide bioclimatically quantified guidelines for the spatial design of courtyard pilotis in hot-humid regions, offering practical insights for optimizing thermal comfort in shaded outdoor environments.
- Open Access
Thermal Mitigation Behaviors of Captive Blue Peafowls and Visitors’ Outdoor Thermal Comfort: A Case Study at Jinan Zoo, China
Zoos play dual roles in wildlife conservation and in providing recreational experiences for visitors in urban green spaces. However, the impacts of thermal environments on both visitor comfort and captive animal welfare remain unexplored, which is an important aspect to address for improving overall zoo management. This study investigated thermal conditions at Jinan Zoo, China, over 20 summer days. Questionnaires were used to collect visitor thermal comfort and viewing satisfaction, while the thermal mitigation behaviors of 70 blue peafowls were recorded under various thermal conditions on-site. The findings showed that the wet-bulb globe temperature (WBGT) neutral range for visitors was 20.1–24.4 °C, with a significant drop in visitor numbers when WBGT exceeded 35.5 °C. Visitors with higher animal viewing satisfaction (aVSV) scores were more heat tolerant. The blue peafowls reduced their activity levels and displayed feather-spreading and gular flutter at WBGT levels of 26.4–30.4 °C, especially during peak visitor hours. Our study also showed that visitor thermal sensation was most affected by radiation, whereas blue peafowl heat stress was likely influenced by air temperature, followed by humidity and radiation. These findings offer practical insights for designing zoo enclosures and visitor areas to improve comfort and animal welfare in hot weather.
Open AccessThermal Mitigation Behaviors of Captive Blue Peafowls and Visitors’ Outdoor Thermal Comfort: A Case Study at Jinan Zoo, China
Zoos play dual roles in wildlife conservation and in providing recreational experiences for visitors in urban green spaces. However, the impacts of thermal environments on both visitor comfort and captive animal welfare remain unexplored, which is an important aspect to address for improving overall zoo management. This study investigated thermal conditions at Jinan Zoo, China, over 20 summer days. Questionnaires were used to collect visitor thermal comfort and viewing satisfaction, while the thermal mitigation behaviors of 70 blue peafowls were recorded under various thermal conditions on-site. The findings showed that the wet-bulb globe temperature (WBGT) neutral range for visitors was 20.1–24.4 °C, with a significant drop in visitor numbers when WBGT exceeded 35.5 °C. Visitors with higher animal viewing satisfaction (aVSV) scores were more heat tolerant. The blue peafowls reduced their activity levels and displayed feather-spreading and gular flutter at WBGT levels of 26.4–30.4 °C, especially during peak visitor hours. Our study also showed that visitor thermal sensation was most affected by radiation, whereas blue peafowl heat stress was likely influenced by air temperature, followed by humidity and radiation. These findings offer practical insights for designing zoo enclosures and visitor areas to improve comfort and animal welfare in hot weather.
- Open Access
Biochar-Based Solutions for Urban Artificial Landscape Water Bodies: Mitigating Eutrophication and Enhancing Visual Aesthetics
This study examines the efficacy of biochar in improving water quality in urban artificial landscape water bodies. Three biochar types—wood biochar, coconut shell biochar, and apricot kernel biochar—were systematically evaluated, along with the purification effects of varying biochar dosages on landscape water. Water quality parameters were quantified using a multiparameter water quality meter, while the enhancement of visual aesthetics was validated through online questionnaires distributed to citizens. The findings include the following: All biochar types significantly reduced eutrophication indices and enhanced visual quality metrics, with coconut shell biochar demonstrating the most pronounced effects. The purification effect correlates with initial water quality and biochar dosage. Water bodies with poorer initial quality tend to show better purification results. While optimal biochar dosage improves water quality parameters, excessive application leads to decreased performance and potential water quality deterioration. Questionnaire analysis of visual preferences for the purified water showed that among biochar types, coconut shell biochar was most preferred (53.2%), followed by apricot kernel biochar (22.8%) and wood biochar (17.2%), while untreated water received the lowest preference (6.8%). When evaluating coconut shell biochar dosages, the 10 g/L treatment achieved the highest preference (67.4%), followed by 5 g/L (18.2%), while both the 15 g/L treatment and untreated water received notably lower preferences (7.1% and 7.3%, respectively). These findings highlight biochar as a promising tool for enhancing both the ecological and aesthetic qualities of urban water bodies, provided its application is carefully tailored to variable environmental conditions.
Open AccessBiochar-Based Solutions for Urban Artificial Landscape Water Bodies: Mitigating Eutrophication and Enhancing Visual Aesthetics
This study examines the efficacy of biochar in improving water quality in urban artificial landscape water bodies. Three biochar types—wood biochar, coconut shell biochar, and apricot kernel biochar—were systematically evaluated, along with the purification effects of varying biochar dosages on landscape water. Water quality parameters were quantified using a multiparameter water quality meter, while the enhancement of visual aesthetics was validated through online questionnaires distributed to citizens. The findings include the following: All biochar types significantly reduced eutrophication indices and enhanced visual quality metrics, with coconut shell biochar demonstrating the most pronounced effects. The purification effect correlates with initial water quality and biochar dosage. Water bodies with poorer initial quality tend to show better purification results. While optimal biochar dosage improves water quality parameters, excessive application leads to decreased performance and potential water quality deterioration. Questionnaire analysis of visual preferences for the purified water showed that among biochar types, coconut shell biochar was most preferred (53.2%), followed by apricot kernel biochar (22.8%) and wood biochar (17.2%), while untreated water received the lowest preference (6.8%). When evaluating coconut shell biochar dosages, the 10 g/L treatment achieved the highest preference (67.4%), followed by 5 g/L (18.2%), while both the 15 g/L treatment and untreated water received notably lower preferences (7.1% and 7.3%, respectively). These findings highlight biochar as a promising tool for enhancing both the ecological and aesthetic qualities of urban water bodies, provided its application is carefully tailored to variable environmental conditions.
- 23 September 2023
- Published by Elsevier in Building and Environment
- Vol. 245
The influence of perceived control on outdoor thermal comfort: A case study in a hot summer and warm winter climate
- 23 September 2023
- Published by Elsevier in Building and Environment
- Vol. 245
The influence of perceived control on outdoor thermal comfort: A case study in a hot summer and warm winter climate
- 9 December 2022
- Published by Elsevier in Building and Environment
- Vol. 229, 109893
Experimental investigation of the effect of surgical masks on outdoor thermal comfort in Xiamen, China
- 9 December 2022
- Published by Elsevier in Building and Environment
- Vol. 229, 109893
Experimental investigation of the effect of surgical masks on outdoor thermal comfort in Xiamen, China