Ehsan Mahmoodi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ehsan Mahmoodi has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Andrew Boyle
Cardiovascular Department, John Hunter Hospital, Newcastle, NSW, Australia; The University of Newcastle, Newcastle, NSW, Australia; Hunter Medical Research Institute, Newcastle, NSW, Australia
2 shared publications- Nicholas Jackson
Department of Cardiology, John Hunter Hospital, Newcastle, Australia
2 shared publications A. Boyle
The Universrity of Newcastle, Newcastle, Australia
1 shared publication- Alireza Asadi
Faculty of Electrical and Computer Engineering Babol Noshirvani University of Technology Babol 47148‐71167 Iran
1 shared publication Allan Davies
Cardiovascular Department, John Hunter Hospital, Newcastle, NSW, Australia
1 shared publicationBlake M. Freeman
Department of Cardiology The Prince Charles Hospital Brisbane Queensland Australia
1 shared publication
Latest Publications
- Open Access
- 26 April 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 9 (6) , ytaf212
Post-prandial high-grade atrioventricular block after gastric sleeve surgery: a case report
Background: Bariatric surgery has been shown to improve long-term cardiovascular outcomes in patients with morbid obesity. However, there is limited data on cardiac arrhythmias occurring after bariatric surgery. We report a case of recurrent syncope due to high-grade atrioventricular block (AVB) after gastric sleeve surgery. Case summary: A 32-year-old woman with a background of morbid obesity and diet-controlled type 2 diabetes mellitus, presented with recurrent post-prandial syncope two months after gastric sleeve surgery. Her 12 lead ECG (electrocardiogram) showed sinus rhythm with non-specific T wave inversion in lead III, and her blood tests including serum electrolytes, thyroid function, and autoimmune screening were all within normal limits. Transthoracic echocardiogram demonstrated a structurally normal heart; however, a 24-h Holter monitor revealed episodes of high-grade AVB, corresponding with post-prandial syncopal episodes. Considering her history of recurrent syncope due to post-prandial high-grade AVB, without any reversible causes, she underwent a dual-chamber permanent pacemaker implantation. At 3 months clinic follow-up she had not experienced any recurrence of syncope. Discussion: Weight loss after bariatric surgery is associated with improved long-term cardiovascular outcomes. However, available data suggests a relationship between bariatric surgery and cardiac bradyarrhythmias. In our case, we report recurrent episodes of syncope due to high-grade AVB after gastric sleeve surgery, treated by permanent pacemaker implantation. To our knowledge, this complication has not been previously reported, and this case highlights the need for further studies to explore the relationship between bariatric surgery and cardiac arrhythmias and to prevent potential complications.
- 26 April 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 9 (6) , ytaf212
Open AccessPost-prandial high-grade atrioventricular block after gastric sleeve surgery: a case report
Background: Bariatric surgery has been shown to improve long-term cardiovascular outcomes in patients with morbid obesity. However, there is limited data on cardiac arrhythmias occurring after bariatric surgery. We report a case of recurrent syncope due to high-grade atrioventricular block (AVB) after gastric sleeve surgery. Case summary: A 32-year-old woman with a background of morbid obesity and diet-controlled type 2 diabetes mellitus, presented with recurrent post-prandial syncope two months after gastric sleeve surgery. Her 12 lead ECG (electrocardiogram) showed sinus rhythm with non-specific T wave inversion in lead III, and her blood tests including serum electrolytes, thyroid function, and autoimmune screening were all within normal limits. Transthoracic echocardiogram demonstrated a structurally normal heart; however, a 24-h Holter monitor revealed episodes of high-grade AVB, corresponding with post-prandial syncopal episodes. Considering her history of recurrent syncope due to post-prandial high-grade AVB, without any reversible causes, she underwent a dual-chamber permanent pacemaker implantation. At 3 months clinic follow-up she had not experienced any recurrence of syncope. Discussion: Weight loss after bariatric surgery is associated with improved long-term cardiovascular outcomes. However, available data suggests a relationship between bariatric surgery and cardiac bradyarrhythmias. In our case, we report recurrent episodes of syncope due to high-grade AVB after gastric sleeve surgery, treated by permanent pacemaker implantation. To our knowledge, this complication has not been previously reported, and this case highlights the need for further studies to explore the relationship between bariatric surgery and cardiac arrhythmias and to prevent potential complications.
- 11 March 2025
- Published by Wiley in Internal Medicine Journal
- Vol. 55 (6) , 913-921
Long‐term outcomes of subcutaneous implantable cardioverter‐defibrillators: a single‐centre Australian experience
Background: The subcutaneous implantable cardioverter‐defibrillator (S‐ICD) has become an established alternative to overcome conventional transvenous ICD (TV‐ICD) lead‐related complications.Aims: To describe the long‐term outcomes of S‐ICD implantation at a single Australian institution.Methods: We retrospectively reviewed the clinical outcomes of consecutive patients who underwent S‐ICD implantation from 2015 to 2019.Results: In total, 128 patients (median age 52.5 years, 70% male) underwent S‐ICD implantation. The indication was primary prevention in 86 patients (66%), and 22 patients (17%) had a previous transvenous device. Seventy‐seven patients (60%) had heart failure, and the median left ventricular ejection fraction was 36% (29%–60%). The procedure was performed under general anaesthesia in 124 patients (97%), and the median procedure time was 105 min (interquartile range (IQR) 90–120). During a median follow‐up of 4.7 years (IQR 3.8–5.8), 15 patients (12%) died, none of which were due to sudden death or device‐related complications. Inappropriate shocks occurred in 17 patients (13.3%), predominantly due to T‐wave oversensing (4.7%) and supraventricular arrhythmias (4.7%), and 15 patients (11.7%) received appropriate shocks. During the follow‐up period, the S‐ICD system was revised to TV‐ICD in 10 patients (8%), and 24 patients (19%) required S‐ICD generator change. Four patients (3%) underwent surgical intervention due to lead (two) or pocket‐related (two) complications, and two patients (1.5%) developed pocket infection without systemic sepsis.Conclusion: In this single‐centre study, S‐ICDs were implanted safely with acceptable device performance and clinical outcomes over long‐term follow‐up.
- 11 March 2025
- Published by Wiley in Internal Medicine Journal
- Vol. 55 (6) , 913-921
Long‐term outcomes of subcutaneous implantable cardioverter‐defibrillators: a single‐centre Australian experience
Background: The subcutaneous implantable cardioverter‐defibrillator (S‐ICD) has become an established alternative to overcome conventional transvenous ICD (TV‐ICD) lead‐related complications.Aims: To describe the long‐term outcomes of S‐ICD implantation at a single Australian institution.Methods: We retrospectively reviewed the clinical outcomes of consecutive patients who underwent S‐ICD implantation from 2015 to 2019.Results: In total, 128 patients (median age 52.5 years, 70% male) underwent S‐ICD implantation. The indication was primary prevention in 86 patients (66%), and 22 patients (17%) had a previous transvenous device. Seventy‐seven patients (60%) had heart failure, and the median left ventricular ejection fraction was 36% (29%–60%). The procedure was performed under general anaesthesia in 124 patients (97%), and the median procedure time was 105 min (interquartile range (IQR) 90–120). During a median follow‐up of 4.7 years (IQR 3.8–5.8), 15 patients (12%) died, none of which were due to sudden death or device‐related complications. Inappropriate shocks occurred in 17 patients (13.3%), predominantly due to T‐wave oversensing (4.7%) and supraventricular arrhythmias (4.7%), and 15 patients (11.7%) received appropriate shocks. During the follow‐up period, the S‐ICD system was revised to TV‐ICD in 10 patients (8%), and 24 patients (19%) required S‐ICD generator change. Four patients (3%) underwent surgical intervention due to lead (two) or pocket‐related (two) complications, and two patients (1.5%) developed pocket infection without systemic sepsis.Conclusion: In this single‐centre study, S‐ICDs were implanted safely with acceptable device performance and clinical outcomes over long‐term follow‐up.
- 23 May 2023
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 51 (10) , 4969-4983
An ultra‐low power and energy‐efficient ternary Half‐Adder based on unary operators and two ternary 3:1 multiplexers in 32‐nm GNRFET technology
Summary: Internet‐of‐Things (IoTs)‐based embedded systems require energy‐efficient designs for long‐term operation. To achieve energy‐efficient designs, multiple‐valued logic (MVL) circuits and graphene nanoribbon field‐effect transistors (GNRFETs) are used instead of binary logic circuits and complementary metal‐oxide‐semiconductor (CMOS), respectively. This paper presents a novel ultra‐low power and energy‐efficient ternary Half‐Adder (THA) circuit based on unary operators, two power supplies (dual‐VDD), VDD and VDD/2, and two ternary 3:1 multiplexers in 32 nm GNRFET technology. The superiority of the proposed design are improvements between 2.86% and 60% in transistor count, between 86.12% and 97.15% in power consumption, and between 58.14% and 98.39% in power‐delay‐product (PDP) compared to existing THA circuits. Moreover, the proposed THA circuit is also implemented with 32 nm carbon nanotube field‐effect transistors (CNTFETs). Simulation results indicate that the proposed GNRFET‐based THA circuit increases delay by 1.74 × and reduces power/PDP by 89.41%/81.63% compared to its CNTFET‐based counterpart.
- 23 May 2023
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 51 (10) , 4969-4983
An ultra‐low power and energy‐efficient ternary Half‐Adder based on unary operators and two ternary 3:1 multiplexers in 32‐nm GNRFET technology
Summary: Internet‐of‐Things (IoTs)‐based embedded systems require energy‐efficient designs for long‐term operation. To achieve energy‐efficient designs, multiple‐valued logic (MVL) circuits and graphene nanoribbon field‐effect transistors (GNRFETs) are used instead of binary logic circuits and complementary metal‐oxide‐semiconductor (CMOS), respectively. This paper presents a novel ultra‐low power and energy‐efficient ternary Half‐Adder (THA) circuit based on unary operators, two power supplies (dual‐VDD), VDD and VDD/2, and two ternary 3:1 multiplexers in 32 nm GNRFET technology. The superiority of the proposed design are improvements between 2.86% and 60% in transistor count, between 86.12% and 97.15% in power consumption, and between 58.14% and 98.39% in power‐delay‐product (PDP) compared to existing THA circuits. Moreover, the proposed THA circuit is also implemented with 32 nm carbon nanotube field‐effect transistors (CNTFETs). Simulation results indicate that the proposed GNRFET‐based THA circuit increases delay by 1.74 × and reduces power/PDP by 89.41%/81.63% compared to its CNTFET‐based counterpart.
- Open Access
- 10 December 2022
- Published by Elsevier in Indian Pacing and Electrophysiology Journal
- Vol. 23 (2) , 47-52
The importance of anaesthesia in atrial fibrillation ablation: Comparing conscious sedation with general anaesthesia
- 10 December 2022
- Published by Elsevier in Indian Pacing and Electrophysiology Journal
- Vol. 23 (2) , 47-52
Open AccessThe importance of anaesthesia in atrial fibrillation ablation: Comparing conscious sedation with general anaesthesia
- Open Access
- 10 February 2021
- Published by Springer Nature in Research Square
Antiarrhythmic Properties of Phenytoin
BACKGROUND: Phenytoin has long been used to treat epilepsy and for some time as an antiarrhythmic drug (AAD). It is known that the diastolic calcium leakage through dysfunctional cardiac ryanodine receptors (RyR2) is a mechanism for arrhythmias in heart failure. Recent evidence suggests that phenytoin inhibits dysfunctional RyR2, reduces the calcium leak during diastole in heart failure, and may improve cardiac systolic function. This indicates the potential for repurposing phenytoin as an AAD in patients with heart failure.METHODS: A systematic search of MEDLINE, Embase, and the Cochrane Library databases was performed in March 2019. The search was limited to the studies published in the English language from 1946 to 2019. Studies on the antiarrhythmic effects of phenytoin in adults compared to no treatment or other AADs were included. Studies were excluded if there was insufficient clinical data regarding antiarrhythmic effects, dosing and administration of phenytoin and other ADDs. Conference abstracts, editorials, case studies and review articles were also excluded. RESULTS: A total of 157 non-duplicate titles were screened, and 25 articles underwent full-text review. 13 studies met the inclusion criteria, representing a total of 985 patients. Phenytoin was found to be effective in treating arrhythmias associated with digitalis toxicity, and in suppressing premature ventricular contractions (PVCs). In a recent animal study, phenytoin inhibited diastolic calcium leak through dysfunctional RyR2 in failing sheep hearts and improved cardiac systolic function without affecting normal functional RyR2.CONCLUSION: Phenytoin has an acceptable safety profile when used as an AAD. It has some utility in treating digitalis-induced arrhythmias and suppressing PVCs, however, further study is needed to determine its efficacy as an antiarrhythmic in heart failure patients given new evidence of its RyR2 stabilising properties.TRIAL REGISTRATION NUMBER: PROSPERO database (CRD42019129125).
- 10 February 2021
- Published by Springer Nature in Research Square
Open AccessAntiarrhythmic Properties of Phenytoin
BACKGROUND: Phenytoin has long been used to treat epilepsy and for some time as an antiarrhythmic drug (AAD). It is known that the diastolic calcium leakage through dysfunctional cardiac ryanodine receptors (RyR2) is a mechanism for arrhythmias in heart failure. Recent evidence suggests that phenytoin inhibits dysfunctional RyR2, reduces the calcium leak during diastole in heart failure, and may improve cardiac systolic function. This indicates the potential for repurposing phenytoin as an AAD in patients with heart failure.METHODS: A systematic search of MEDLINE, Embase, and the Cochrane Library databases was performed in March 2019. The search was limited to the studies published in the English language from 1946 to 2019. Studies on the antiarrhythmic effects of phenytoin in adults compared to no treatment or other AADs were included. Studies were excluded if there was insufficient clinical data regarding antiarrhythmic effects, dosing and administration of phenytoin and other ADDs. Conference abstracts, editorials, case studies and review articles were also excluded. RESULTS: A total of 157 non-duplicate titles were screened, and 25 articles underwent full-text review. 13 studies met the inclusion criteria, representing a total of 985 patients. Phenytoin was found to be effective in treating arrhythmias associated with digitalis toxicity, and in suppressing premature ventricular contractions (PVCs). In a recent animal study, phenytoin inhibited diastolic calcium leak through dysfunctional RyR2 in failing sheep hearts and improved cardiac systolic function without affecting normal functional RyR2.CONCLUSION: Phenytoin has an acceptable safety profile when used as an AAD. It has some utility in treating digitalis-induced arrhythmias and suppressing PVCs, however, further study is needed to determine its efficacy as an antiarrhythmic in heart failure patients given new evidence of its RyR2 stabilising properties.TRIAL REGISTRATION NUMBER: PROSPERO database (CRD42019129125).
- Open Access
- 8 November 2020
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 29, S71
076 Antiarrhythmic Properties of Phenytoin: A Systematic Review
- 8 November 2020
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 29, S71
Open Access076 Antiarrhythmic Properties of Phenytoin: A Systematic Review