Chen Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chen Lin has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Guanhao Wu
State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, China
2 shared publications - Siyu Zhou
Tsinghua University
2 shared publications - Liheng Shi
Yangtze Delta Region Institute of Tsinghua University
1 shared publication - Mali Gong
State Key Laboratory of Precision Measurement Technology and Instruments, Tsinghua University, Beijing 100084, China
1 shared publication - Qiang Liu
State Key Laboratory of Petroleum Resources and Prospecting, College of Mechanical and Transportation Engineering, China University of Petroleum, Beijing 102249, China
1 shared publication - Ruixue Zhang
School of Mathematics and Statistics Qingdao University China
1 shared publication
Latest Publications
- 17 January 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (3) , 526-529
Two-dimensional angle measurement with sub-arcsecond precision and MHz update rate using heterodyne interferometry with optical frequency comb
Heterodyne interferometry is a powerful tool for achieving high precision and fast measurement. We developed an angle measurement system based on heterodyne interferometry by combining discrete equal-spacing longitudinal modes of optical frequency comb with an acousto-optic modulator. Using a self-designed grating-corner-cube sensor, this method can achieve a two-dimensional angle measurement with sub-arcsecond accuracy and megahertz (MHz) update rate. We experimentally demonstrate a precision of 0.073 arcsec under a 3 MHz update rate, and comparison residuals are kept within 0.063 arcsec over 300 arcsec when compared to a piezo stage. In the dynamic measurement of a 40 Hz frequency, the continuous sinusoidal motion of 0.05 arcsec can be clearly distinguished and reconstructed.
- 17 January 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (3) , 526-529
Two-dimensional angle measurement with sub-arcsecond precision and MHz update rate using heterodyne interferometry with optical frequency comb
Heterodyne interferometry is a powerful tool for achieving high precision and fast measurement. We developed an angle measurement system based on heterodyne interferometry by combining discrete equal-spacing longitudinal modes of optical frequency comb with an acousto-optic modulator. Using a self-designed grating-corner-cube sensor, this method can achieve a two-dimensional angle measurement with sub-arcsecond accuracy and megahertz (MHz) update rate. We experimentally demonstrate a precision of 0.073 arcsec under a 3 MHz update rate, and comparison residuals are kept within 0.063 arcsec over 300 arcsec when compared to a piezo stage. In the dynamic measurement of a 40 Hz frequency, the continuous sinusoidal motion of 0.05 arcsec can be clearly distinguished and reconstructed.
- 5 December 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (26) , 46001-46009
Dual-comb ranging method for simultaneously measuring the refractive index and surface spacing in a multi-lens system
Precise determination of the refractive index and surface spacing in multi-lens system is essential for ultra-precision system performance, such as lithography objectives with strict requirements for each lens fabrication and assembly position. Generally, the nominal value of the refractive index at a given wavelength must be known before resolving the geometric thickness of multi-lens using conventional methods, which leads to inaccurate and inconvenient measurements. We propose a method to simultaneously measure the refractive index and surface spacing in multi-lens system based on dual-comb ranging method. The precision of the thickness measurement is better than 0.18 µm, and the refractive index is better than 1.6 × 10−4. This study provides a potential solution for realizing the real-time, fast, and precise measurement of the geometric thickness and assembly position of multi-lens in lithography objectives.
- 5 December 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (26) , 46001-46009
Dual-comb ranging method for simultaneously measuring the refractive index and surface spacing in a multi-lens system
Precise determination of the refractive index and surface spacing in multi-lens system is essential for ultra-precision system performance, such as lithography objectives with strict requirements for each lens fabrication and assembly position. Generally, the nominal value of the refractive index at a given wavelength must be known before resolving the geometric thickness of multi-lens using conventional methods, which leads to inaccurate and inconvenient measurements. We propose a method to simultaneously measure the refractive index and surface spacing in multi-lens system based on dual-comb ranging method. The precision of the thickness measurement is better than 0.18 µm, and the refractive index is better than 1.6 × 10−4. This study provides a potential solution for realizing the real-time, fast, and precise measurement of the geometric thickness and assembly position of multi-lens in lithography objectives.
- Open Access
- 31 August 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (18) , 21981-21992
12 J, 10 Hz diode-pumped Nd:YAG distributed active mirror amplifier chain with ASE suppression
Experimental amplification of 10-ns pulses to an energy of 12.2 J at the repetition rate of 1-10 Hz is reported from a diode-pumped room-temperature distributed active mirror amplifier chain (DAMAC) based on Nd:YAG slabs. Efficient power scaling at the optical-optical efficiency of 20.6% was achieved by suppressing the transverse parasitic oscillation with ASE absorbers. To the best of our knowledge, this is the first demonstration of a diode-pumped Nd:YAG active-mirror laser with nanosecond pulse energy beyond 10 joules. The verified DAMAC concept holds the promise of scaling the energy to a 50 J level and higher by adding 10-12 more pieces of active mirror in the chain.
- 31 August 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (18) , 21981-21992
Open Access12 J, 10 Hz diode-pumped Nd:YAG distributed active mirror amplifier chain with ASE suppression
Experimental amplification of 10-ns pulses to an energy of 12.2 J at the repetition rate of 1-10 Hz is reported from a diode-pumped room-temperature distributed active mirror amplifier chain (DAMAC) based on Nd:YAG slabs. Efficient power scaling at the optical-optical efficiency of 20.6% was achieved by suppressing the transverse parasitic oscillation with ASE absorbers. To the best of our knowledge, this is the first demonstration of a diode-pumped Nd:YAG active-mirror laser with nanosecond pulse energy beyond 10 joules. The verified DAMAC concept holds the promise of scaling the energy to a 50 J level and higher by adding 10-12 more pieces of active mirror in the chain.