Jefferson Flórez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jefferson Flórez has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Jeff S. Lundeen
3 shared publicationsCodey H. Nacke
Department of Physics and Centre for Research in Photonics University of Ottawa 25 Templeton Street K1N 6N5 Ottawa Ontario Canada
2 shared publicationsDavor Curic
Department of Physics and Centre for Research in Photonics, University of Ottawa, 25 Templeton Street, Ottawa, Ontario K1N 6N5, Canada
2 shared publications- Jeff S. Lundeen
University of Ottawa
2 shared publications Lambert Giner
Department of Physics and Centre for Research in Photonics University of Ottawa 25 Templeton Street K1N 6N5 Ottawa Ontario Canada
2 shared publications- Lambert Giner
Department of Physics and Centre for Research in Photonics, University of Ottawa, 25 Templeton Street, Ottawa, Ontario, Canada K1N 6N5
2 shared publications
Latest Publications
- Open Access
- 1 September 2024
- Published by AIP Publishing in APL Quantum
- Vol. 1 (3)
Coupling undetected sensing modes by quantum erasure
Imaging with undetected photons (IUP) enables the possibility of sensing changes in the phase and the transmission of a beam of light that need never be detected. This has led to the possibility of infrared sensing with visible silicon camera technology, for example. Relying on the interference of two identical pairs of photons, IUP was initially achieved using unidirectional paths through two nonlinear crystal pair sources. More recently, folded arrangements using bidirectional paths through a single-crystal have become common for their simplicity. Here, we theoretically model and experimentally implement a novel setup involving three interference paths through a single nonlinear crystal. This establishes two independent IUP sensing modes in addition to a third linear interference mode. We achieve this using a polarization state quantum eraser approach, with excellent agreement between experiment and theory. This system provides a new route to control and optimize IUP interference in a single-crystal folded arrangement by using controllable quantum erasure to balance the interferometer, opening the door to new implementations and applications for IUP.
- 1 September 2024
- Published by AIP Publishing in APL Quantum
- Vol. 1 (3)
Open AccessCoupling undetected sensing modes by quantum erasure
Imaging with undetected photons (IUP) enables the possibility of sensing changes in the phase and the transmission of a beam of light that need never be detected. This has led to the possibility of infrared sensing with visible silicon camera technology, for example. Relying on the interference of two identical pairs of photons, IUP was initially achieved using unidirectional paths through two nonlinear crystal pair sources. More recently, folded arrangements using bidirectional paths through a single-crystal have become common for their simplicity. Here, we theoretically model and experimentally implement a novel setup involving three interference paths through a single nonlinear crystal. This establishes two independent IUP sensing modes in addition to a third linear interference mode. We achieve this using a polarization state quantum eraser approach, with excellent agreement between experiment and theory. This system provides a new route to control and optimize IUP interference in a single-crystal folded arrangement by using controllable quantum erasure to balance the interferometer, opening the door to new implementations and applications for IUP.
- 28 July 2020
- Published by Optica Publishing Group in Optics Letters
- Vol. 45 (15) , 4264-4267
Pump depletion in parametric down-conversion with low pump energies
We report the efficient generation of high-gain parametric down-conversion, including pump depletion, with pump powers as low as 100 µW (energies 0.1 µJ/pulse) and conversion efficiencies up to 33%. In our simple configuration, the pump beam is tightly focused into a bulk periodically poled lithium niobate crystal placed in free space. We also observe a change in the photon number statistics for both the pump and down-converted beams as the pump power increases to reach the depleted pump regime. The experimental results are a clear signature of the interplay between the pump and the down-converted beams in highly efficient parametric down-conversion sources.
- 28 July 2020
- Published by Optica Publishing Group in Optics Letters
- Vol. 45 (15) , 4264-4267
Pump depletion in parametric down-conversion with low pump energies
We report the efficient generation of high-gain parametric down-conversion, including pump depletion, with pump powers as low as 100 µW (energies 0.1 µJ/pulse) and conversion efficiencies up to 33%. In our simple configuration, the pump beam is tightly focused into a bulk periodically poled lithium niobate crystal placed in free space. We also observe a change in the photon number statistics for both the pump and down-converted beams as the pump power increases to reach the depleted pump regime. The experimental results are a clear signature of the interplay between the pump and the down-converted beams in highly efficient parametric down-conversion sources.
- Open Access
Pump depletion in parametric down-conversion with low pump energies
We report the efficient generation of high-gain parametric down-conversion, including pump depletion, with pump powers as low as 100 $\mu$W (energies $0.1$~$\mu$J/pulse) and conversion efficiencies up to 33\%. In our simple configuration, the pump beam is tightly focused into a bulk periodically poled lithium niobate crystal placed in free space. We also observe a change in the photon number statistics for both the pump and down-converted beams as the pump power increases to reach the depleted pump regime. The experimental results are a clear signature of the interplay between the pump and the down-converted beams in highly efficient parametric down-conversion sources.
Open AccessPump depletion in parametric down-conversion with low pump energies
We report the efficient generation of high-gain parametric down-conversion, including pump depletion, with pump powers as low as 100 $\mu$W (energies $0.1$~$\mu$J/pulse) and conversion efficiencies up to 33\%. In our simple configuration, the pump beam is tightly focused into a bulk periodically poled lithium niobate crystal placed in free space. We also observe a change in the photon number statistics for both the pump and down-converted beams as the pump power increases to reach the depleted pump regime. The experimental results are a clear signature of the interplay between the pump and the down-converted beams in highly efficient parametric down-conversion sources.
- Open Access
- 1 December 2018
- Published by IOP Publishing in New Journal of Physics
- Vol. 20 (12) , 123022
The phase sensitivity of a fully quantum three-mode nonlinear interferometer
We study a nonlinear interferometer consisting of two consecutive parametric amplifiers, where all three optical fields (pump, signal and idler) are treated quantum mechanically, allowing for pump depletion and other quantum phenomena. The interaction of all three fields in the final amplifier leads to an interference pattern from which we extract the phase uncertainty. We find that the phase uncertainty oscillates around a saturation level that decreases as the mean number N of input pump photons increases. For optimal interaction strengths, we also find a phase uncertainty below the shot-noise level and obtain a Heisenberg scaling . This is in contrast to the conventional treatment within the parametric approximation, where the Heisenberg scaling is observed as a function of the number of down-converted photons inside the interferometer.
- 1 December 2018
- Published by IOP Publishing in New Journal of Physics
- Vol. 20 (12) , 123022
Open AccessThe phase sensitivity of a fully quantum three-mode nonlinear interferometer
We study a nonlinear interferometer consisting of two consecutive parametric amplifiers, where all three optical fields (pump, signal and idler) are treated quantum mechanically, allowing for pump depletion and other quantum phenomena. The interaction of all three fields in the final amplifier leads to an interference pattern from which we extract the phase uncertainty. We find that the phase uncertainty oscillates around a saturation level that decreases as the mean number N of input pump photons increases. For optimal interaction strengths, we also find a phase uncertainty below the shot-noise level and obtain a Heisenberg scaling . This is in contrast to the conventional treatment within the parametric approximation, where the Heisenberg scaling is observed as a function of the number of down-converted photons inside the interferometer.
- Open Access
The phase sensitivity of a fully quantum three-mode nonlinear interferometer
We study a nonlinear interferometer consisting of two consecutive parametric amplifiers, where all three optical fields (pump, signal and idler) are treated quantum mechanically, allowing for pump depletion and other quantum phenomena. The interaction of all three fields in the final amplifier leads to an interference pattern from which we extract the phase uncertainty. We find that the phase uncertainty oscillates around a saturation level that decreases as the mean number $N$ of input pump photons increases. For optimal interaction strengths, we also find a phase uncertainty below the shot-noise level and obtain a Heisenberg scaling $1/N$. This is in contrast to the conventional treatment within the parametric approximation, where the Heisenberg scaling is observed as a function of the number of down-converted photons inside the interferometer.Open AccessThe phase sensitivity of a fully quantum three-mode nonlinear interferometer
We study a nonlinear interferometer consisting of two consecutive parametric amplifiers, where all three optical fields (pump, signal and idler) are treated quantum mechanically, allowing for pump depletion and other quantum phenomena. The interaction of all three fields in the final amplifier leads to an interference pattern from which we extract the phase uncertainty. We find that the phase uncertainty oscillates around a saturation level that decreases as the mean number $N$ of input pump photons increases. For optimal interaction strengths, we also find a phase uncertainty below the shot-noise level and obtain a Heisenberg scaling $1/N$. This is in contrast to the conventional treatment within the parametric approximation, where the Heisenberg scaling is observed as a function of the number of down-converted photons inside the interferometer. - Open Access
A variable partially-polarizing beam splitter
We present designs for variably polarizing beam splitters. These are beam splitters allowing the complete and independent control of the horizontal and vertical polarization splitting ratios. They have quantum optics and quantum information applications, such as quantum logic gates for quantum computing and non-local measurements for quantum state estimation. At the heart of each design is an interferometer. We experimentally demonstrate one particular implementation, a displaced Sagnac interferometer configuration, that provides an inherent instability to air currents and vibrations. Furthermore, this design does not require any custom-made optics but only common components which can be easily found in an optics laboratory.
Open AccessA variable partially-polarizing beam splitter
We present designs for variably polarizing beam splitters. These are beam splitters allowing the complete and independent control of the horizontal and vertical polarization splitting ratios. They have quantum optics and quantum information applications, such as quantum logic gates for quantum computing and non-local measurements for quantum state estimation. At the heart of each design is an interferometer. We experimentally demonstrate one particular implementation, a displaced Sagnac interferometer configuration, that provides an inherent instability to air currents and vibrations. Furthermore, this design does not require any custom-made optics but only common components which can be easily found in an optics laboratory.
- 1 February 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (2) , 023108
A variable partially polarizing beam splitter
We present designs for variably polarizing beam splitters. These are beam splitters allowing the complete and independent control of the horizontal and vertical polarization splitting ratios. They have quantum optics and quantum information applications, such as quantum logic gates for quantum computing and non-local measurements for quantum state estimation. At the heart of each design is an interferometer. We experimentally demonstrate one particular implementation, a displaced Sagnac interferometer configuration, that provides an inherent instability to air currents and vibrations. Furthermore, this design does not require any custom-made optics but only common components which can be easily found in an optics laboratory.
- 1 February 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (2) , 023108
A variable partially polarizing beam splitter
We present designs for variably polarizing beam splitters. These are beam splitters allowing the complete and independent control of the horizontal and vertical polarization splitting ratios. They have quantum optics and quantum information applications, such as quantum logic gates for quantum computing and non-local measurements for quantum state estimation. At the heart of each design is an interferometer. We experimentally demonstrate one particular implementation, a displaced Sagnac interferometer configuration, that provides an inherent instability to air currents and vibrations. Furthermore, this design does not require any custom-made optics but only common components which can be easily found in an optics laboratory.