Adrian V. Timbus
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Adrian V. Timbus has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Pedro Rodriguez
Luxembourg Institute of Science and Technology, Esch-sur-Alzette, Luxembourg
6 shared publications - Remus Teodorescu
Aalborg University
6 shared publications - Frede Blaabjerg
Aalborg University
5 shared publications - Marco Liserre
Dept. of Electrotecnichal and Electronic Eng., 70125-Bari, Italy
3 shared publications - Mihai Ciobotaru
EcoJoule Energy, Brisbane, QLD, Australia
2 shared publications
Latest Publications
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 02759306,p. 2306-2312
Online grid impedance estimation for single-phase grid-connected systems using PQ variations
This paper presents an online grid impedance estimation method for single-phase grid-connected systems, such as photovoltaic systems, small wind turbines, fuel-cells power systems. The method is based on producing a small perturbation on the output of the power converter that is in the form of periodical variations of active and reactive power (PQ variations). The main idea is to make the power converter working in two operation points in order to solve the equation of the equivalent grid impedance. During the perturbation, measurements of voltage and current are performed and signal processing algorithms are used in order to estimate the value of the grid impedance. The online grid impedance estimation method can be used for compliance with the anti-islanding standard requirements (IEEE1574, IEEE929 and VDE0126) and for adaptive control of the grid-connected converters. The proposed method is embedded in the existing power converter control. The selected results validate the effectiveness of the proposed method.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 02759306,p. 2306-2312
Online grid impedance estimation for single-phase grid-connected systems using PQ variations
This paper presents an online grid impedance estimation method for single-phase grid-connected systems, such as photovoltaic systems, small wind turbines, fuel-cells power systems. The method is based on producing a small perturbation on the output of the power converter that is in the form of periodical variations of active and reactive power (PQ variations). The main idea is to make the power converter working in two operation points in order to solve the equation of the equivalent grid impedance. During the perturbation, measurements of voltage and current are performed and signal processing algorithms are used in order to estimate the value of the grid impedance. The online grid impedance estimation method can be used for compliance with the anti-islanding standard requirements (IEEE1574, IEEE929 and VDE0126) and for adaptive control of the grid-connected converters. The proposed method is embedded in the existing power converter control. The selected results validate the effectiveness of the proposed method.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 02759306,p. 1273-1279
Line Impedance Estimation Using Active and Reactive Power Variations
This paper proposes an estimation method of power system impedance based on power variations caused by a distributed power generation system (DPGS) at the point of common coupling (PCC). The proposed algorithm is computationally simple and uses the voltage variations at the point of common coupling (PCC) caused by the variations of the power delivered to utility network to derive the value of grid impedance. Accurate estimation of both resistive and inductive part of the impedance is obtained, as the results presented show.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 02759306,p. 1273-1279
Line Impedance Estimation Using Active and Reactive Power Variations
This paper proposes an estimation method of power system impedance based on power variations caused by a distributed power generation system (DPGS) at the point of common coupling (PCC). The proposed algorithm is computationally simple and uses the voltage variations at the point of common coupling (PCC) caused by the variations of the power delivered to utility network to derive the value of grid impedance. Accurate estimation of both resistive and inductive part of the impedance is obtained, as the results presented show.
- 1 November 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1553572X,p. 5185-5190
Independent PQ Control for Distributed Power Generation Systems under Grid Faults
This work aims to present a generalized vector-based formulation for calculating the grid-side current reference of distributed power generation systems in order to independently control active and reactive power delivered to the grid. Strategies for current reference generation were implemented on the abc stationary reference frame and their effectiveness was demonstrated experimentally, perhaps validating the theoretical analysis even under grid fault conditions
- 1 November 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1553572X,p. 5185-5190
Independent PQ Control for Distributed Power Generation Systems under Grid Faults
This work aims to present a generalized vector-based formulation for calculating the grid-side current reference of distributed power generation systems in order to independently control active and reactive power delivered to the grid. Strategies for current reference generation were implemented on the abc stationary reference frame and their effectiveness was demonstrated experimentally, perhaps validating the theoretical analysis even under grid fault conditions
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2 (01972618) , 1015-1023
Linear and Nonlinear Control of Distributed Power Generation Systems
In this paper, different control structures applied to distributed power generation system are discussed. Implementation of proportional-integral (PI), proportional-resonant (PR), hysteresis and dead beat controller in different reference frames is also treated. An evaluation in terms of current harmonic distortion when running in steady state condition is made. Additionally, the controllers' behavior in transient operation such as step in current reference and single phase fault in the utility grid has also been studied. Experimental results are presented for their evaluation
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2 (01972618) , 1015-1023
Linear and Nonlinear Control of Distributed Power Generation Systems
In this paper, different control structures applied to distributed power generation system are discussed. Implementation of proportional-integral (PI), proportional-resonant (PR), hysteresis and dead beat controller in different reference frames is also treated. An evaluation in terms of current harmonic distortion when running in steady state condition is made. Additionally, the controllers' behavior in transient operation such as step in current reference and single phase fault in the utility grid has also been studied. Experimental results are presented for their evaluation
- 1 July 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1608-1612
Grid Monitoring for Distributed Power Generation Systems to Comply with Grid Codes
This paper investigates the possibility of using the phase-locked loop (PLL) algorithms for grid monitoring. The main interest is on the ability of the PLL to determine accurately other grid variables except the phase angle. The main focus is set on the voltage amplitude and frequency estimation but other attributes of the PLL systems such as the possibility to detect unbalance and to extract the positive and negative sequence from the grid voltages are also discussed. A detailed description of standards for wind turbine (WT) and photovoltaic (PV) systems regarding grid monitoring is given and the simulation results of the proposed PLL are compared with the values stated in these standards. Based on this comparison, it can be concluded that PLL system can be used with success for grid monitoring
- 1 July 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1608-1612
Grid Monitoring for Distributed Power Generation Systems to Comply with Grid Codes
This paper investigates the possibility of using the phase-locked loop (PLL) algorithms for grid monitoring. The main interest is on the ability of the PLL to determine accurately other grid variables except the phase angle. The main focus is set on the voltage amplitude and frequency estimation but other attributes of the PLL systems such as the possibility to detect unbalance and to extract the positive and negative sequence from the grid voltages are also discussed. A detailed description of standards for wind turbine (WT) and photovoltaic (PV) systems regarding grid monitoring is given and the simulation results of the proposed PLL are compared with the values stated in these standards. Based on this comparison, it can be concluded that PLL system can be used with success for grid monitoring
- 1 July 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2 (21635137) , 1601-1607
Control Strategies for Distributed Power Generation Systems Operating on Faulty Grid
The distributed power generation based on renewable energy sources such as wind and sun experiences a high penetration in the power systems around the world, having in some countries a large contribution to the total energy production. In order to protect the distribution and transmission systems, the grid operators are more and more talking about the ability of the distribution systems (mainly wind turbines WT systems) to behave as a conventional power plant. This paper discusses the possibilities of the distributed power generation systems (DPGS) to deliver power when grid disturbances are present in the utility network. The focus is set more on the control strategies for active power generation, and mainly on the creation of the reference currents which fulfill the demanded output power. Considerations about reactive power are also stated. Experimental results are presented in order to validate the theory behind the proposed control strategies on faulty grid
- 1 July 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2 (21635137) , 1601-1607
Control Strategies for Distributed Power Generation Systems Operating on Faulty Grid
The distributed power generation based on renewable energy sources such as wind and sun experiences a high penetration in the power systems around the world, having in some countries a large contribution to the total energy production. In order to protect the distribution and transmission systems, the grid operators are more and more talking about the ability of the distribution systems (mainly wind turbines WT systems) to behave as a conventional power plant. This paper discusses the possibilities of the distributed power generation systems (DPGS) to deliver power when grid disturbances are present in the utility network. The focus is set more on the control strategies for active power generation, and mainly on the creation of the reference currents which fulfill the demanded output power. Considerations about reactive power are also stated. Experimental results are presented in order to validate the theory behind the proposed control strategies on faulty grid