MRMaxence Rateaux

Maxence Rateaux

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Maxence Rateaux has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Anatomical and sensorimotor relations in congenital oculomotor disorders

    by Maxence Rateaux

    Corrélations anatomo-sensori-motrices dans les dysfonctions oculomotrices congénitales: Les troubles oculomoteurs sont souvent associés à des dysfonctions sensorielles. La démonstration des corrélations entre désordres moteurs et dysfonctions sensorielles d’une part offre des perspectives de quantification des dysfonctions sensorielles en pédiatrie, d’autre part permet de formuler de nouvelles hypothèses sur la neuro-anatomie fonctionnelle de l’oculomotricité. Chez six patients présentant un nystagmus précoce et une position de calme excentrée, des enregistrements oculomoteurs (EOM) ont été réalisés, permettant le calcul du « expanded nystagmus acuity function » (NAFX) dans 17 positions du regard. Ces enregistrements permettent une quantification objective des effets de la chirurgie sur le déplacement de la zone de calme du nystagmus. Des EOM ont été réalisés chez 40 patients présentant un nystagmus précoce (23 albinos, 7 idiopathiques et 10 aniridiques). L’étude des ondes de formes et des données cliniques a permis de réfuter l’hypothèse d’une onde de forme spécifique dans l’albinisme. Il existe néanmoins des corrélations entre le type d’onde et le niveau d’acuité visuelle. La prise en compte de l’angle lambda est importante en pédiatrie ; bien qu’aucune méthode objective de quantification ne soit utilisable en pratique clinique. Nous avons développé une méthode fiable, reproductible et accessible permettant la mesure de cet angle à partir de clichés photographiques. La répétabilité et la validité de la méthode sur 20 yeux sains en comparant la mesure avec une méthode déjà validée ont été testées. Chez 140 yeux sains les valeurs de cet angle dans différentes conditions de luminance, les valeurs biométriques oculaires et les fluctuations de l’angle en fonction de l’état de dilatation pupillaire ont été quantifiés. La valeur moyenne de l’angle est de +2.73° ± 2.72°. Des corrélations négatives entre l’angle lambda, la longueur axiale et la profondeur de la chambre antérieure ont été démontrées. Chez un sujet donné, l’angle lambda varie en fonction de la dilation pupillaire, avec une diminution au cours du myosis. L’angle lambda important modifie l’aspect esthétique du strabisme. À partir d’une série de patients présentant une association entre angle lambda et strabisme, nous proposons une classification de l’aspect visuel du strabisme en fonction de sa valeur corrélée à l’angle lambda. L’étude des reflets cornéens utilisée dans le cadre de dépistage du strabisme peut présenter de nombreux faux négatifs. Le syndrome de Möbius se caractérise par une paralysie du regard horizontal empêchant l’utilisation de l’examen sous écran pour dépister un strabisme. Chez 34 patients avec un syndrome de Möbius, une mesure semi-automatique du strabisme et de l’angle lambda ont permis une quantification du strabisme. 17 présentaient une ésotropie, 1 patient une exotropie, 5 patients un micro-strabisme et 11 étaient orthophoriques. L’albinisme se caractérise par une hypopigmentation oculaire et cutanée et une hyper-décussation des fibres chiasmatiques. La présence d’un angle lambda hyper-positif résulterait d’un décalage temporal de la fovéa due à l’anomalie de décussation. Nous avons développé un algorithme capable d’étudier les variations de l’angle lambda chez un patient nystagmique à partir d’une séquence filmographique. Cent sept patients présentant un albinisme ont été recrutés. L’angle lambda et la distance papille-fovéa (DPF) étaient supérieurs au groupe contrôle. L’existence d’une corrélation positive entre la DPF et l’angle lambda a permis de valider l’hypothèse de départ. Enfin, la corrélation de l’angle lambda avec l’acuité visuelle et les autres signes cliniques permet d’intégrer cet angle comme nouveau critère clinique de sévérité de l’albinisme. Le développement de méthodes objectives de quantification des troubles oculomoteurs permet une amélioration du phénotypage de ces troubles. Les corrélations entre état oculomoteur et fonction sensorielle offrent de nouvelles possibilités d’appréciation de la fonction visuelle.

  • Open Access

    Albinism: Management and care of ophthalmological manifestations

    by Maxence Rateaux, Dominique Bremond-Gignac, Matthieu P. Robert


  • Open Access

    Fluctuations in angle lambda with the pupil diameter and correlations with biometric values in a healthy population

    by Maxence Rateaux, Alienor Vienne‐Jumeau, Dominique Bremond‐Gignac, Matthieu P. Robert

    Purpose: Angle lambda ( λ ) is defined as the angle between the line of sight and the pupillary axis at the entrance pupil. We previously developed a child‐friendly and portable method to measure this angle in daily practice. In a given population, angle λ fluctuates according to age or refractive error. As changes in the pupil diameter induce changes in the location of the pupil centre, it was hypothesised that a given subject will exhibit several angles λ , varying with the luminance level. The study aimed to investigate correlations between angle λ and biometric values and to analyse the effects of pupil dilation and entrance pupil location on angle λ . Method: The study was performed on 70 right eyes from 70 participants (58 women, 12 men; mean age 22.91 ± 2.57 years). Angle λ was assessed under photopic and scotopic luminance conditions. Angle λ was also measured under standard luminance conditions in a subgroup of 15 eyes. Axial length, anterior chamber depth, chord μ (coaxial corneal light reflex position) and the optic disc to fovea distance (OFD) were also measured. The pupil centre offset was quantified by digital analysis. Results: Mean photopic and scotopic angle λ values were +2.81 ± 2.34° and +3.30 ± 2.59°, respectively. A negative correlation was found between axial length, anterior chamber depth or OFD and both photopic and scotopic angle λ . A positive correlation was found between spherical equivalent or chord μ and angle λ . The mean pupil offset was significantly higher under photopic than scotopic conditions and was negatively correlated with angle λ for both luminance levels. Conclusion: This study confirms that angle λ is correlated with biometric values. Furthermore, fluctuation of pupil diameter induces variations in angle λ . Thus, a given subject exhibits several angles λ according to the luminance level.

  • Open Access

    Chiasmal Decussation in Oculo-Cutaneous Albinism Type 8

    by Maxence Rateaux, Smaïl Hadj-Rabia, Rémi Barrois, Olivia Zambrowski, Vincent Michaud, Ester Moreno-Artero, Dominique Bremond-Gignac, Sophie Javerzat, Matthieu P. Robert

    Albinism is a genetic disorder characterized by a defect in melanin biosynthesis. Ophthalmological and dermatological impairments vary according to the patient genotype and are highly heterogenous. Recently, variants in the DCT gene were showed to be responsible for a new type of oculocutaneous albinism (OCA) named OCA8. We report the ophthalmological, electrophysiological, and dermatological characteristics of three patients with genetically confirmed OCA8. This is a retrospective study of three patients with OCA8. Complete dermatological, ophthalmological, and orthoptic examinations were performed with clinical exploration and multimodal imaging. Visual evoked potentials (VEPs) were performed to characterize chiasmal decussation in two of the three patients. The dermatological phenotype was mild, whereas all three patients exhibited infantile nystagmus syndrome with reduced visual acuity, foveal hypoplasia (grade 3), macular hypopigmentation (graded from 2 to 1), and iris transillumination (grade 3). Patients who could undergo a VEP examination exhibited signs of strong chiasmal misrouting. Recently, pathogenic variants in the DCT gene were proven to cause OCA. Whereas patients with OCA8 exhibit a milder dermatological phenotype than others, their vision was initially described as impaired. The present report confirms previous findings and suggests that chiasmal misrouting is present in OCA8. This, together with recent findings in the murine model, supports the hypothesis that DCT regulates levels of L-Dopa and downstream signaling in the developing retina. These results convey critical future therapeutic implications.


  • Open Access

    Method to Quickly Map Multifocal Pupillary Response Fields (mPRF) Using Frequency Tagging

    by Jean Lorenceau, Suzon Ajasse, Raphael Barbet, Muriel Boucart, Frédéric Chavane, Cédric Lamirel, Richard Legras, Frédéric Matonti, Maxence Rateaux, Jean-François Rouland, et al.

    We present a method for mapping multifocal Pupillary Response Fields in a short amount of time using a visual stimulus covering 40° of the visual angle divided into nine contiguous sectors simultaneously modulated in luminance at specific, incommensurate, temporal frequencies. We test this multifocal Pupillary Frequency Tagging (mPFT) approach with young healthy participants (N = 36) and show that the spectral power of the sustained pupillary response elicited by 45 s of fixation of this multipartite stimulus reflects the relative contribution of each sector/frequency to the overall pupillary response. We further analyze the phase lag for each temporal frequency as well as several global features related to pupil state. Test/retest performed on a subset of participants indicates good repeatability. We also investigate the existence of structural (RNFL)/functional (mPFT) relationships. We then summarize the results of clinical studies conducted with mPFT on patients with neuropathies and retinopathies and show that the features derived from pupillary signal analyses, the distribution of spectral power in particular, are homologous to disease characteristics and allow for sorting patients from healthy participants with excellent sensitivity and specificity. This method thus appears as a convenient, objective, and fast tool for assessing the integrity of retino-pupillary circuits as well as idiosyncrasies and permits to objectively assess and follow-up retinopathies or neuropathies in a short amount of time.


  • Congenital trochlear-oculomotor synkinesis with ptosis

    by Maxence Rateaux, Romain Touze, Dominique Bremond-Gignac


  • From monocular photograph to angle lambda: A new clinical approach for quantitative assessment

    by Maxence Rateaux, Dominique Bremond-Gignac, Matthieu P. Robert

    Ophthalmologic and physiological optics relies on several specific axes.1,2 The relationship between these axes defines several angles: alpha (α), kappa (κ), and lambda (λ). There is no consensus i...


  • Pseudo-Gaze Deviation Resulting From Positive Angle Kappa and Esotropia

    by Maxence Rateaux, Marie-Andrée Espinasse-Berrod, Chloé Couret, Dominique Bremond-Gignac, Matthieu P. Robert

    A 6-year-old boy was referred for constant right gaze deviation. Rather than a gaze deviation, he constantly seemed to look on the left side of any displayed target. Examination revealed the association of a highly positive angle Kappa and an esotropia of equal values. He also exhibited signs of ocular albinism with no associated infantile nystagmus syndrome. The X-linked ocular albinism was confirmed genetically, explaining the presence of a positive angle Kappa. A highly positive angle Kappa can be associated with a convergent strabismus; in case both values offset each other, this can result in a constant “sidelooking,” which should not be confused with a gaze deviation.