Guanghui Wei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Guanghui Wei has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Xuxu Lyu
National Key Laboratory of Electromagnetic Environment Effects, Army Engineering University Shijiazhuang Campus , Shijiazhuang, Hebei 050003
2 shared publications - Haojiang Wan
National Key Laboratory on Electromagnetic Environment Effects, Army Engineering University, Shijiazhuang Campus, Shijiazhuang, China
1 shared publication Hongze Zhao
1 shared publicationJiangning Sun
1 shared publication- Xinfu Lu
National Key Laboratory of Electromagnetic Environment Effects, Shijiazhuang Campus, Army Engineering University, Shijiazhuang 050003, China
1 shared publication Xue Du
1 shared publication
Latest Publications
- 14 December 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (3) , 035014
Numerical simulation of the ignition law for a hot bridge wire electroexplosive device
Hot bridge wire electroexplosive devices (EEDs) are widely used as starting elements in aerospace and other fields. Their thermal ignition process and safety testing technology have always been a focus of research. In this paper, we construct a temperature rise model for a hot bridge wire EED by using the law of conservation of energy, and the temperature response of the bridge wire and the reagent is obtained. According to the theoretical and numerical analysis, the sensitive criterion for a hot bridge wire EED is given, and the simulation process for the critical ignition current is designed. Based on this process, the law of the influence of the bridge wire and reagent parameters on the ignition of a hot bridge wire EED was studied. The research results show that a first derivative of the reagent temperature with respect to the radial distance of greater than zero is a sensitive criterion for the ignition of a hot bridge wire EED with high accuracy. Compared with traditional numerical methods, the proposed process makes the acquisition of the critical ignition current more precise and programmable due to the use of sensitive criteria. In addition, the following significant features are noted: the critical ignition current first increases as the square root of the bridge wire radius and then linearly; the square of the critical ignition current increases linearly with the activation energy of the reagent; there is rapid exponential decay of the critical ignition current with increasing reagent combustion heat; asymptotic values are present. In engineering use, it is possible to conveniently design the ignition characteristics of a hot bridge wire EED by changing the radius of the bridge wire. This study serves as a foundational work for the safety testing of hot bridge wire EEDs and can provide theoretical guidance for the safety testing, actual production and use of hot bridge wire EEDs.
- 14 December 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (3) , 035014
Numerical simulation of the ignition law for a hot bridge wire electroexplosive device
Hot bridge wire electroexplosive devices (EEDs) are widely used as starting elements in aerospace and other fields. Their thermal ignition process and safety testing technology have always been a focus of research. In this paper, we construct a temperature rise model for a hot bridge wire EED by using the law of conservation of energy, and the temperature response of the bridge wire and the reagent is obtained. According to the theoretical and numerical analysis, the sensitive criterion for a hot bridge wire EED is given, and the simulation process for the critical ignition current is designed. Based on this process, the law of the influence of the bridge wire and reagent parameters on the ignition of a hot bridge wire EED was studied. The research results show that a first derivative of the reagent temperature with respect to the radial distance of greater than zero is a sensitive criterion for the ignition of a hot bridge wire EED with high accuracy. Compared with traditional numerical methods, the proposed process makes the acquisition of the critical ignition current more precise and programmable due to the use of sensitive criteria. In addition, the following significant features are noted: the critical ignition current first increases as the square root of the bridge wire radius and then linearly; the square of the critical ignition current increases linearly with the activation energy of the reagent; there is rapid exponential decay of the critical ignition current with increasing reagent combustion heat; asymptotic values are present. In engineering use, it is possible to conveniently design the ignition characteristics of a hot bridge wire EED by changing the radius of the bridge wire. This study serves as a foundational work for the safety testing of hot bridge wire EEDs and can provide theoretical guidance for the safety testing, actual production and use of hot bridge wire EEDs.
- Open Access
Feasibility and Error Analysis of Using Fiber Optic Temperature Measurement Device to Evaluate the Electromagnetic Safety of Hot Bridge Wire EEDs
Most studies assessing the safety of hot bridge wire EEDs employ temperature sensors that directly use the measurements of the temperature measurement device without analyzing the accuracy of the temperature measurement. This study establishes the response function of the exposed bridge and exposed bridge temperature rise system of hot bridge wire EEDs through the Rosenthal’s temperature rise equation and Laplace transformation as well as experimental tests, and through the response function, the response law and numerical characteristics of the two are compared and analyzed under four typical excitations. Under steady current injection and continuous-wave radiation, both exposed bridge and exposed bridge temperature measurement systems can reach thermal equilibrium, and the equilibrium temperature of both are the same. However, under pulse excitation, the temperature rise measurement value is significantly different from the actual value due to the large difference in response time of the exposed bridge (1 ms) and the exposed bridge temperature measurement device (0.82 s). Studies have shown that under steady current injection and continuous-wave radiation, temperature rise measurements can be directly applied to the safety assessment of hot bridge wire EEDs, while under pulsed conditions, temperature rise measurements cannot be directly applied.
Open AccessFeasibility and Error Analysis of Using Fiber Optic Temperature Measurement Device to Evaluate the Electromagnetic Safety of Hot Bridge Wire EEDs
Most studies assessing the safety of hot bridge wire EEDs employ temperature sensors that directly use the measurements of the temperature measurement device without analyzing the accuracy of the temperature measurement. This study establishes the response function of the exposed bridge and exposed bridge temperature rise system of hot bridge wire EEDs through the Rosenthal’s temperature rise equation and Laplace transformation as well as experimental tests, and through the response function, the response law and numerical characteristics of the two are compared and analyzed under four typical excitations. Under steady current injection and continuous-wave radiation, both exposed bridge and exposed bridge temperature measurement systems can reach thermal equilibrium, and the equilibrium temperature of both are the same. However, under pulse excitation, the temperature rise measurement value is significantly different from the actual value due to the large difference in response time of the exposed bridge (1 ms) and the exposed bridge temperature measurement device (0.82 s). Studies have shown that under steady current injection and continuous-wave radiation, temperature rise measurements can be directly applied to the safety assessment of hot bridge wire EEDs, while under pulsed conditions, temperature rise measurements cannot be directly applied.