XLXiaofeng Liang

Xiaofeng Liang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xiaofeng Liang has a total of 60 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Relaxation spectral analysis in multi‐contrast vascular magnetic particle imaging

    by Xin Feng, Guang Jia, Jiaming Peng, Liyu Huang, Xiaofeng Liang, Haoran Zhang, Yanjun Liu, Bo Zhang, Yifei Zhang, Meng Sun, et al.

    Background: Magnetic nanoparticles (MNPs) are used as tracers without ionizing radiation in vascular imaging, molecular imaging, and neuroimaging. The relaxation mechanisms of magnetization in response to excitation magnetic fields are important features of MNPs. The basic relaxation mechanisms include internal rotation (Néel relaxation) and external physical rotation (Brownian relaxation). Accurate measurement of these relaxation times may provide high sensitivity for predicting MNP types and viscosity‐based hydrodynamic states. It is challenging to separately measure the Néel and Brownian relaxation components using sinusoidal excitation in conventional MPI.Purpose: We developed a multi‐exponential relaxation spectral analysis method to separately measure the Néel and Brownian relaxation times in the magnetization recovery process in pulsed vascular MPI.Methods: Synomag‐D samples with different viscosities were excited using pulsed excitation in a trapezoidal‐waveform relaxometer. The samples were excited at different field amplitudes ranging from 0.5 to 10 mT at intervals of 0.5 mT. The inverse Laplace transform‐based spectral analysis of the relaxation‐induced decay signal in the field‐flat phase was performed by using PDCO, a primal‐dual interior method for convex objectives. Néel and Brownian relaxation peaks were elucidated and measured on samples with various glycerol and gelatin concentrations. The sensitivity of viscosity prediction of the decoupled relaxation times was evaluated. A digital vascular phantom was designed to mimic a plaque with viscous MNPs and a catheter with immobilized MNPs. Spectral imaging of the digital vascular phantom was simulated by combining a field‐free point with homogeneous pulsed excitation. The relationship between the Brownian relaxation time from different tissues and the number of periods for signal averages was evaluated for a scan time estimation in the simulation.Results: The relaxation spectra of synomag‐D samples with different viscosity levels exhibited two relaxation time peaks. The Brownian relaxation time had a positive linear relationship with the viscosity in the range 0.9 to 3.2 mPa · s. When the viscosity was >3.2 mPa · s, the Brownian relaxation time saturated and did not change with increasing viscosity. The Néel relaxation time decreased slightly with an increase in the viscosity. The Néel relaxation time exhibited a similar saturation effect when the viscosity level was >3.2 mPa · s for all field amplitudes. The sensitivity of the Brownian relaxation time increased with the field amplitude and was maximized at approximately 4.5 mT. The plaque and catheter regions were differentiated from the vessel region in the simulated Brownian relaxation time map. The simulation results show that the Néel relaxation time was 8.33±0.09 μs in the plaque region, 8.30±0.08 μs in the catheter region, and 8.46±0.11 μs in the vessel region. The Brownian relaxation time was 36.60±2.31 μs in the plaque region, 30.17±1.24 μs in the catheter region, and 31.21±1.53 μs in the vessel region. If we used 20 excitation periods for image acquisition in the simulation, the total scan time of the digital phantom was approximately 100 s.Conclusion: Quantitative assessment of the Néel and Brownian relaxation times through inverse Laplace transform‐based spectral analysis in pulsed excitation, highlighting their potential for use in multi‐contrast vascular MPI.


  • Open Access

    Pandemic Preparedness and Response in the post-COVID-19 era: Governance and PHSMs

    by Yanping Zhang, Chao Ma, Yi Cai, Zijian Feng, Xiaofeng Liang

    In this workshop we will review the experiences and lessons learnt in the fight against COVID-19 in China for the purpose of better preparing for and responding to future pandemics, from the following perspectives: Taking a whole-of-government and a whole-of-society approach for the governance...

  • Gradient-Based Pulsed Excitation and Relaxation Encoding in Magnetic Particle Imaging

    by Guang Jia, Liyu Huang, Ze Wang, Xiaofeng Liang, Yu Zhang, Yifei Zhang, Qiguang Miao, Kai Hu, Tanping Li, Ying Wang, et al.

    Magnetic particle imaging (MPI) is a radiation-free vessel- and target-imaging modality that can sensitively detect nanoparticles. A static magnetic gradient field, referred to as a selection field, is required in MPI to provide a field-free region (FFR) for spatial encoding. The image resolution of MPI is closely related to the size of the FFR, which is determined by the selection field gradient amplitude. Because of the limitations of existing gradient coil hardware, the image resolution of MPI cannot satisfy the clinical requirements of human in vivo imaging. Pulsed excitation has been confirmed to improve the image resolution of MPI by breaking down the ’relaxation wall.’ This work proposes the use of a pulsed waveform magnetic gradient from magnetic resonance imaging to further improve the image resolution of MPI. Through alignment of the gradient direction along the field-free line (FFL), each location on the FFL is able to have a unique excitation field strength that generates a specific relaxation-induced decay signal. Through excitation of nanoparticles on the FFL with many gradient profiles, a high-resolution, one-dimensional (1D) image can be reconstructed on the FFL. For larger magnetic nanoparticles, simulation results revealed that a pulsed excitation field with a greater flat portion generates a 1D bar pattern phantom image with a higher correlation and spatial resolution. With parallel FFL and gradient coil movements, high-resolution, two-dimensional (2D) Shepp–Logan phantom and brain vessel maps were reconstructed through repetition of the spatially resolved measurement of magnetic nanoparticles on the FFL.


  • Open Access

    Improved influenza vaccination coverage among health-care workers: evidence from a web-based survey in China, 2019/2020 season

    by Heya Yi, Yuan Yang, Li Zhang, Muli Zhang, Qing Wang, Ting Zhang, Yuyuan Zhang, Ying Qin, Zhibin Peng, Zhiwei Leng, et al.

    To understand influenza vaccination and its correlates among health-careworkers (HCWs) during the 2019/2020 season in China, we used a self-administeredelectronic questionnaire to collect information on demographics, occupational characteristics, influenza vaccination status and access to free vaccination on the “Breath Circles”, a Chinese media platform for respiratory medical professionals. The reported influenza vaccine coverage among HCWs during this season was 67%, with more HCWs in a workplace with free vaccination than those with no free vaccination (79% vs.34%,p < .001). The influenza vaccine coverage among HCWs who were required or encouraged to get vaccinated by the workplace was significantly higher than that without any intervention measures (80% & 70 vs.39%,p < .001). The vaccine coverage in the workplaces with free and required vaccination simultaneously was highest compared to that with neither free vaccination nor any intervention measures (OR = 14.86, 95% CI: 10.93–20.20). The influenza vaccination coverage of HCWs in high-riskdepartments was significantly higher than that of other departments (70% vs.58%,p =.023). HCWs’ vaccine coverage was related to personal opinions and attitudes toward influenza or influenza vaccines, as well as other constraints such as availability of influenza vaccines, workplace regulations, and access to free vaccines.


  • Immunogenicity, antibody persistence, and safety of the 60 μg hepatitis B vaccine in hemodialysis patients: a multicenter, randomized, double-blind, parallel-controlled trial

    by Yongliang Feng, Xiaohong Shi, Jing Shi, Linying Gao, Guangming Liu, Yanpeng Cheng, Minghu Pan, Chunxia Li, Jun Wang, Xuxia Guo, et al.

    Background: To evaluate the immunogenicity, antibody persistence, and safety of the 60 µg hepatitis B vaccine in hemodialysis patients in China. Methods: We conducted a multicenter, randomized, double-blind, parallel-controlled trial including 352 hemodialysis patients who were centrally randomized in a ratio of 1:1 to receive a 20 µg (IM20 group) or 60 µg (IM60 group) recombinant hepatitis B vaccine at months 0, 1, and 6. Results: The vaccine-elicited antibody responses peaked at month 7, and declined at month 12. At month 7, the IM60 group had stronger GMC of anti-HBs, and a higher proportion of seroconversion and high-level response than the IM20 group did (P < 0.05). Better immune responses were observed in the IM60 group, especially for those aged or in the high-frequency hemodialysis population. Conclusion: The high dose 60 µg recombinant hepatitis B vaccines elicited stronger immune responses than the 20 µg hepatitis B vaccine did among hemodialysis patients. Clinical trial registration: ClinicalTrials.gov, number NCT02963714.


  • The long-term efficacy, 13–23 years, of a plasma-derived hepatitis B vaccine in highly endemic areas in China

    by Feng Wang, Liping Shen, Fuqiang Cui, Shuang Zhang, Hui Zheng, Yong Zhang, Xiaofeng Liang, Fuzhen Wang, Shengli Bi


  • Open Access

    Impact of Supplementary Immunization Activities in Measles-Endemic Areas: A Case Study From Guangxi, China

    by Jiatong Zhuo, Wenkui Geng, Edward J. Hoekstra, Ge Zhong, Xiaofeng Liang, Jian Zhang

    Because of limited resources, each year during the period from 1999 through 2007, only about one-quarter of the 111 counties in Guangxi province were selected by means of risk assessment to participate in Supplementary Immunization Activities (SIAs), targeting children aged 8 months to 14 years during 1999–2003 and 8 months to 10 years during 2004–2007. Approximately 2 million doses of measles vaccines were administrated each year during SIAs. Estimated from the National Notifiable Diseases Surveillance System, with a reliable internal consistency over years, the average annual incidences of measles before SIAs (1993–1998), during the first phase (1999–2003), and during the second phase (2004–2007) were 16.05, 9.10, and 2.46 cases per 100,000, respectively. The overall provincewide annual incidence decreased by 84.67%, from 12.12 cases per 100,000 in 2000 to 2.10 cases per 100,000 in 2007. The percentage of counties with annual incidence ≥10 cases per 100,000 decreased from 55% in 1993 to <1% in 2007. Compared with the pre-SIA period, the greatest decrease in annual incidence was 83.93% for the 10–14.9-year-old group and the smallest decrease was 46.16% for children <1 year old. The multiple-year SIAs targeting children in selected high-risk counties were effective in controlling measles in mountainous, impoverished, and multiethnic measles-endemic areas.