Sohail G. Contractor
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sohail G. Contractor has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Alex Merkulov
1 shared publicationAzadeh Esmaeili
University of Medicine and Dentistry of New Jersey-New Jersey Medical School
1 shared publicationDavid Klyde
1 shared publicationDiego Reina
University of Medicine and Dentistry of New Jersey-New Jersey Medical School
1 shared publicationEdwin Deitch
University of Medicine and Dentistry of New Jersey-New Jersey Medical School
1 shared publicationKim Gardner
1 shared publication
Latest Publications
- 28 April 2011
- Published by SAGE Publications in Vascular and Endovascular Surgery
- Vol. 45 (4) , 345-351
Incomplete Deployment of the Vena Tech LP Filter-Case Series and Concerns
The Vena Tech LP vena cava filter (B Braun, Evanston, Illinois) has been FDA approved since 2001 and is a permanent vena cava filtration device. It replaced the previous Vena tech LGM filter also manufactured by B Braun. The LGM filter had 2 case series reporting a high incidence of incomplete deployment of the filter, especially when placed from a jugular approach. Design changes were made to this device and the LP filter introduced. The LP filter has also been reported to have incompletely deployed both in peer reviewed literature as well as the FDA MAUDE website. We present here 3 cases of incomplete deployment of the Vena Tech LP filter and review the cases previously described as well as attempt to present possible etiologies for incomplete deployment.
- 28 April 2011
- Published by SAGE Publications in Vascular and Endovascular Surgery
- Vol. 45 (4) , 345-351
Incomplete Deployment of the Vena Tech LP Filter-Case Series and Concerns
The Vena Tech LP vena cava filter (B Braun, Evanston, Illinois) has been FDA approved since 2001 and is a permanent vena cava filtration device. It replaced the previous Vena tech LGM filter also manufactured by B Braun. The LGM filter had 2 case series reporting a high incidence of incomplete deployment of the filter, especially when placed from a jugular approach. Design changes were made to this device and the LP filter introduced. The LP filter has also been reported to have incompletely deployed both in peer reviewed literature as well as the FDA MAUDE website. We present here 3 cases of incomplete deployment of the Vena Tech LP filter and review the cases previously described as well as attempt to present possible etiologies for incomplete deployment.
- 1 August 2009
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 20 (8) , 1093-1095
Penetration of Günther Tulip Filter Struts through an Introducer Sheath: Case Report and Safety Concerns
- 1 August 2009
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 20 (8) , 1093-1095
Penetration of Günther Tulip Filter Struts through an Introducer Sheath: Case Report and Safety Concerns
- 1 August 2009
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 20 (8) , 1052-1058
Single-incision Technique for Tunneled Central Venous Access
- 1 August 2009
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 20 (8) , 1052-1058
Single-incision Technique for Tunneled Central Venous Access