Mallika Gummalla
Mallika Gummalla has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
N. S. Erikhman
Russian Academy of Science Institute of Biochemical Physics Kosygin str. 4 119334 Moscow Russia
3 shared publicationsN. Y. Kuzminyh
Russian Academy of Science Institute of Biochemical Physics Kosygin str. 4, Moscow 119334 Russia
3 shared publicationsD. V. Dmitriev
Russian Academy of Science Institute of Biochemical Physics Kosygin str. 4, Moscow 119334 Russia
2 shared publicationsS. F. Burlatsky
United Technologies Research Center 411 06108 Silver Lane East Hartford CT USA
2 shared publications- Sergei F. Burlatsky
United Technologies Research Center
2 shared publications V. V. Atrazhev
Russian Academy of Science Institute of Biochemical Physics Kosygin str. 4 119334 Moscow Russia
2 shared publications
Latest Publications
- Open Access
Effect of Particle Size and Operating Conditions on Pt3Co PEMFC Cathode Catalyst Durability
The initial performance and decay trends of polymer electrolyte membrane fuel cells (PEMFC) cathodes with Pt3Co catalysts of three mean particle sizes (4.9 nm, 8.1 nm, and 14.8 nm) with identical Pt loadings are compared. Even though the cathode based on 4.9 nm catalyst exhibited the highest initial electrochemical surface area (ECA) and mass activity, the cathode based on 8.1 nm catalyst showed better initial performance at high currents. Owing to the low mass activity of the large particles, the initial performance of the 14.8 nm Pt3Co-based electrode was the lowest. The performance decay rate of the electrodes with the smallest Pt3Co particle size was the highest and that of the largest Pt3Co particle size was lowest. Interestingly, with increasing number of decay cycles (0.6 to 1.0 V, 50 mV/s), the relative improvement in performance of the cathode based on 8.1 nm Pt3Co over the 4.9 nm Pt3Co increased, owing to better stability of the 8.1 nm catalyst. The electron microprobe analysis (EMPA) of the decayed membrane-electrode assembly (MEA) showed that the amount of Co in the membrane was lower for the larger particles, and the platinum loss into the membrane also decreased with increasing particle size. This suggests that the higher initial performance at high currents with 8.1 nm Pt3Co could be due to lower contamination of the ionomer in the electrode. Furthermore, lower loss of Co from the catalyst with increased particle size could be one of the factors contributing to the stability of ECA and mass activity of electrodes with larger cathode catalyst particles. To delineate the impact of particle size and alloy effects, these results are compared with prior work from our research group on size effects of pure platinum catalysts. The impact of PEMFC operating conditions, including upper potential, relative humidity, and temperature on the alloy catalyst decay trends, along with the EMPA analysis of the decayed MEAs, are reported.
Open AccessEffect of Particle Size and Operating Conditions on Pt3Co PEMFC Cathode Catalyst Durability
The initial performance and decay trends of polymer electrolyte membrane fuel cells (PEMFC) cathodes with Pt3Co catalysts of three mean particle sizes (4.9 nm, 8.1 nm, and 14.8 nm) with identical Pt loadings are compared. Even though the cathode based on 4.9 nm catalyst exhibited the highest initial electrochemical surface area (ECA) and mass activity, the cathode based on 8.1 nm catalyst showed better initial performance at high currents. Owing to the low mass activity of the large particles, the initial performance of the 14.8 nm Pt3Co-based electrode was the lowest. The performance decay rate of the electrodes with the smallest Pt3Co particle size was the highest and that of the largest Pt3Co particle size was lowest. Interestingly, with increasing number of decay cycles (0.6 to 1.0 V, 50 mV/s), the relative improvement in performance of the cathode based on 8.1 nm Pt3Co over the 4.9 nm Pt3Co increased, owing to better stability of the 8.1 nm catalyst. The electron microprobe analysis (EMPA) of the decayed membrane-electrode assembly (MEA) showed that the amount of Co in the membrane was lower for the larger particles, and the platinum loss into the membrane also decreased with increasing particle size. This suggests that the higher initial performance at high currents with 8.1 nm Pt3Co could be due to lower contamination of the ionomer in the electrode. Furthermore, lower loss of Co from the catalyst with increased particle size could be one of the factors contributing to the stability of ECA and mass activity of electrodes with larger cathode catalyst particles. To delineate the impact of particle size and alloy effects, these results are compared with prior work from our research group on size effects of pure platinum catalysts. The impact of PEMFC operating conditions, including upper potential, relative humidity, and temperature on the alloy catalyst decay trends, along with the EMPA analysis of the decayed MEAs, are reported.
- Open Access
A Mathematical Model for Predicting the Life of PEM Fuel Cell Membranes Subjected to Hydration Cycling
Under typical PEM fuel cell operating conditions, part of membrane electrode assembly is subjected to humidity cycling due to variation of inlet gas RH and/or flow rate. Cyclic membrane hydration/dehydration would cause cyclic swelling/shrinking of the unconstrained membrane. In a constrained membrane, it causes cyclic stress resulting in mechanical failure in the area adjacent to the gas inlet. A mathematical modeling framework for prediction of the lifetime of a PEM FC membrane subjected to hydration cycling is developed in this paper. The model predicts membrane lifetime as a function of RH cycling amplitude and membrane mechanical properties. The modeling framework consists of three model components: a fuel cell RH distribution model, a hydration/dehydration induced stress model that predicts stress distribution in the membrane, and a damage accrual model that predicts membrane life-time. Short descriptions of the model components along with overall framework are presented in the paper. The model was used for lifetime prediction of a GORE-SELECT membrane.
Open AccessA Mathematical Model for Predicting the Life of PEM Fuel Cell Membranes Subjected to Hydration Cycling
Under typical PEM fuel cell operating conditions, part of membrane electrode assembly is subjected to humidity cycling due to variation of inlet gas RH and/or flow rate. Cyclic membrane hydration/dehydration would cause cyclic swelling/shrinking of the unconstrained membrane. In a constrained membrane, it causes cyclic stress resulting in mechanical failure in the area adjacent to the gas inlet. A mathematical modeling framework for prediction of the lifetime of a PEM FC membrane subjected to hydration cycling is developed in this paper. The model predicts membrane lifetime as a function of RH cycling amplitude and membrane mechanical properties. The modeling framework consists of three model components: a fuel cell RH distribution model, a hydration/dehydration induced stress model that predicts stress distribution in the membrane, and a damage accrual model that predicts membrane life-time. Short descriptions of the model components along with overall framework are presented in the paper. The model was used for lifetime prediction of a GORE-SELECT membrane.
- Open Access
The Dynamics of Platinum Precipitation in an Ion Exchange Membrane
Microscopy of polymer electrolyte membranes that have undergone operation under fuel cell conditions, have revealed a well defined band of platinum in the membrane. Here, we propose a physics based model that captures the mechanism of platinum precipitation in the polymer electrolyte membrane. While platinum is observed throughout the membrane, the preferential growth of platinum at the band of platinum is dependent on the electrochemical potential distribution in the membrane. In this paper, the location of the platinum band is calculated as a function of the gas concentration at the cathode and anode, gas diffusion coefficients and solubility constants of the gases in the membrane, which are functions of relative humidity. Under H2/N2 conditions the platinum band is located near the cathode-membrane interface, as the oxygen concentration in the cathode gas stream increases and/or the hydrogen concentration in the anode gas stream decreases, the band moves towards the anode. The model developed in this paper agrees with the set of experimental data on the platinum band location and the platinum particle distribution and size.
Open AccessThe Dynamics of Platinum Precipitation in an Ion Exchange Membrane
Microscopy of polymer electrolyte membranes that have undergone operation under fuel cell conditions, have revealed a well defined band of platinum in the membrane. Here, we propose a physics based model that captures the mechanism of platinum precipitation in the polymer electrolyte membrane. While platinum is observed throughout the membrane, the preferential growth of platinum at the band of platinum is dependent on the electrochemical potential distribution in the membrane. In this paper, the location of the platinum band is calculated as a function of the gas concentration at the cathode and anode, gas diffusion coefficients and solubility constants of the gases in the membrane, which are functions of relative humidity. Under H2/N2 conditions the platinum band is located near the cathode-membrane interface, as the oxygen concentration in the cathode gas stream increases and/or the hydrogen concentration in the anode gas stream decreases, the band moves towards the anode. The model developed in this paper agrees with the set of experimental data on the platinum band location and the platinum particle distribution and size.
- 1 January 2011
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 158 (3) , B322-B330
The Dynamics of Platinum Precipitation in an Ion Exchange Membrane
Microscopy of polymer electrolyte membranes (PEMs) that have undergone operation under fuel cell conditions, have revealed a well defined band of platinum in the membrane. Here, we propose a physics based model that captures the mechanism of platinum precipitation in the polymer electrolyte membrane. While platinum is observed throughout the membrane, preferential growth of the platinum at the band of platinum is dependent on the electrochemical potential distribution in the membrane. In this paper, the location of the platinum band is calculated as a function of gas concentration at the cathode and anode, gas diffusion coefficients, and solubility constants of the gases in the membrane, which are functions of relative humidity. Potential cycling the PEM fuel cell under H2∕N2H2∕N2 conditions that resulted in the platinum band is near the cathode-membrane interface. As the oxygen concentration in the cathode gas stream increases and/or the hydrogen concentration in the anode gas stream decreases, the band moves toward the anode. The model developed in this paper agrees with the set of experimental data on the platinum band location and the platinum particle distribution and size.
- 1 January 2011
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 158 (3) , B322-B330
The Dynamics of Platinum Precipitation in an Ion Exchange Membrane
Microscopy of polymer electrolyte membranes (PEMs) that have undergone operation under fuel cell conditions, have revealed a well defined band of platinum in the membrane. Here, we propose a physics based model that captures the mechanism of platinum precipitation in the polymer electrolyte membrane. While platinum is observed throughout the membrane, preferential growth of the platinum at the band of platinum is dependent on the electrochemical potential distribution in the membrane. In this paper, the location of the platinum band is calculated as a function of gas concentration at the cathode and anode, gas diffusion coefficients, and solubility constants of the gases in the membrane, which are functions of relative humidity. Potential cycling the PEM fuel cell under H2∕N2H2∕N2 conditions that resulted in the platinum band is near the cathode-membrane interface. As the oxygen concentration in the cathode gas stream increases and/or the hydrogen concentration in the anode gas stream decreases, the band moves toward the anode. The model developed in this paper agrees with the set of experimental data on the platinum band location and the platinum particle distribution and size.
- 1 January 2010
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 157 (11) , B1542-B1548
Degradation of Polymer-Electrolyte Membranes in Fuel Cells
A physics-based theoretical model that predicts the chemical degradation of the perfluorosulfonic acid polymer electrolyte membrane during fuel cell operation is developed. The model includes the transport and reaction of crossover gases, hydrogen and oxygen, to produce radicals in the membrane that subsequently react with the polymer to release hydrogen fluoride. The model assumes that a uniform distribution of nanometer-sized platinum deposits in the membrane (as a model input) originating from cathode dissolution provides the sites for radical generation. The degradation rate, measured by the release of hydrogen fluoride, depends on the net radical generation sites in the membrane, the concentration of the crossover gases, the hydration level of the membrane, the operating temperature, the operating voltage, and the thickness of the membrane. The model-predicted trends agree well with those reported and with our experimental results reported in the first article of this series by Madden et al. [ J. Electrochem. Soc. , 156 , B657 (2009)] . Furthermore, the model provides insight to the factors that affect radical generation vs radical quenching, which aids in explaining the experimentally observed nonlinear trends of fluoride emission with reactant concentration and membrane thickness.
- 1 January 2010
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 157 (11) , B1542-B1548
Degradation of Polymer-Electrolyte Membranes in Fuel Cells
A physics-based theoretical model that predicts the chemical degradation of the perfluorosulfonic acid polymer electrolyte membrane during fuel cell operation is developed. The model includes the transport and reaction of crossover gases, hydrogen and oxygen, to produce radicals in the membrane that subsequently react with the polymer to release hydrogen fluoride. The model assumes that a uniform distribution of nanometer-sized platinum deposits in the membrane (as a model input) originating from cathode dissolution provides the sites for radical generation. The degradation rate, measured by the release of hydrogen fluoride, depends on the net radical generation sites in the membrane, the concentration of the crossover gases, the hydration level of the membrane, the operating temperature, the operating voltage, and the thickness of the membrane. The model-predicted trends agree well with those reported and with our experimental results reported in the first article of this series by Madden et al. [ J. Electrochem. Soc. , 156 , B657 (2009)] . Furthermore, the model provides insight to the factors that affect radical generation vs radical quenching, which aids in explaining the experimentally observed nonlinear trends of fluoride emission with reactant concentration and membrane thickness.