Aruna Tripathy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Aruna Tripathy has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Abhyarthana Bisoyi
School of Electronic Sciences, Odisha University of Technology and Research, Bhubaneswar, India
2 shared publications - Rani Pradhan
Odisha University of Technology and Research
2 shared publications - Sukanta Kumar Swain
Centurian University of Technology and Management
2 shared publications - Abhyarthana Bisoyi
Odisha University of Technology and Research
1 shared publication - Aishwarya Dash
Odisha University of Technology and Research, Bhubaneswar, India
1 shared publication - Ananya Dastidar
Odisha University of Technology and Research
1 shared publication
Latest Publications
- 2 September 2026
- Published by Springer Nature
- p. 915-927
Temperature-Dependent Performance Analysis of Hetero Junction Dual Gate Vertical TFET
- 2 September 2026
- Published by Springer Nature
- p. 915-927
Temperature-Dependent Performance Analysis of Hetero Junction Dual Gate Vertical TFET
- 27 February 2026
- Published by Springer Nature in Journal of Computational Electronics
- Vol. 25 (2) , 73
Impact of oxide layer engineering on HJ-DG-VTFET performance and its application in gas sensing
- 27 February 2026
- Published by Springer Nature in Journal of Computational Electronics
- Vol. 25 (2) , 73
Impact of oxide layer engineering on HJ-DG-VTFET performance and its application in gas sensing
- 2 January 2026
- Published by Springer Nature
- p. 93-107
Analog Performance Evaluation of a Gate Stack Engineered Double Oxide Tunnel Field Effect Transistor
- 2 January 2026
- Published by Springer Nature
- p. 93-107
Analog Performance Evaluation of a Gate Stack Engineered Double Oxide Tunnel Field Effect Transistor
- Open Access
- 22 October 2025
- Published by Springer Nature in Research Square
Simulation of Polymeric Microstructures for Biosensing Applications using COMSOL Multiphysics
Applications in the field of biomedical engineering have been made possible by the rapid advancement of MEMS (micro-electronic-mechanical) systems. The field of biosensing application has benefited greatly from the quick development of polymeric micro cantilever technology. In this study, polycrystalline silicon, and polydimethylsiloxane (PDMS) is used as substrate elements for the biosensor. The polymer has been proposed for numerous uses, including sensing, due to its intriguing characteristics. When compared to other sensors, PDMS offers highly amazing sensing capabilities. A biosensor is a tool that detects the build-up of biological species, such as biomolecules or even biological compositions. It primarily consists of three categories: a signal-generating component that fundamentally identifies the biological species, a signal transducer, and a reading device. To determine the minimal force needed for a divergence of and to demonstrate the application of polymeric micro-cantilevers for the accurate early detection of diseases like HIV (Human Immunodeficiency Virus) and TB (Tuberculosis). This paper presents simulation results of cantilevers made of polymeric materials and compares them to cantilevers made of standard polysilicon. Polymeric micro cantilever simulations for biosensor applications were carried out using the Multiphysics simulation program COMSOL 5.3. As a final thought, we can presume that affordable, biocompatible, and straightforward-to-produce sensors are absent from the health care system today. It is synthesized on a single-use, cost-effective basis using micro-cantilevers and micro-beams. PDMS is an elastomer that is frequently used to create medical microstructures based on specifications. For the application, having Young's modulus of under 750 kPa is highly desirable and 160 GPa for Polycrystalline Silicon. The paper focuses on creating and simulating PDMS cantilever structures of devices that have already been made in the lab, as well as assessing the specific divergence that will be used to determine the precise mass that should be placed on the edge of these micro-structures. To improve the device's sensitivity, a modification to the microcantilever beam's design is unavoidable. The project contains a study of the sensitivity of the microcantilever biosensor to improve the deflection of the microcantilever beam by considering several parameters including the length of the beam, the thickness of the beam, and some shape modifications of the microcantilever beam. The microcantilever beam's length or thickness can be changed to increase or decrease the deflection. The deflection values for two microcantilever beam forms with identical length, thickness, and materials are noted, and it is inferred that shape alteration will increase the microcantilever beam's deflection.
- 22 October 2025
- Published by Springer Nature in Research Square
Open AccessSimulation of Polymeric Microstructures for Biosensing Applications using COMSOL Multiphysics
Applications in the field of biomedical engineering have been made possible by the rapid advancement of MEMS (micro-electronic-mechanical) systems. The field of biosensing application has benefited greatly from the quick development of polymeric micro cantilever technology. In this study, polycrystalline silicon, and polydimethylsiloxane (PDMS) is used as substrate elements for the biosensor. The polymer has been proposed for numerous uses, including sensing, due to its intriguing characteristics. When compared to other sensors, PDMS offers highly amazing sensing capabilities. A biosensor is a tool that detects the build-up of biological species, such as biomolecules or even biological compositions. It primarily consists of three categories: a signal-generating component that fundamentally identifies the biological species, a signal transducer, and a reading device. To determine the minimal force needed for a divergence of and to demonstrate the application of polymeric micro-cantilevers for the accurate early detection of diseases like HIV (Human Immunodeficiency Virus) and TB (Tuberculosis). This paper presents simulation results of cantilevers made of polymeric materials and compares them to cantilevers made of standard polysilicon. Polymeric micro cantilever simulations for biosensor applications were carried out using the Multiphysics simulation program COMSOL 5.3. As a final thought, we can presume that affordable, biocompatible, and straightforward-to-produce sensors are absent from the health care system today. It is synthesized on a single-use, cost-effective basis using micro-cantilevers and micro-beams. PDMS is an elastomer that is frequently used to create medical microstructures based on specifications. For the application, having Young's modulus of under 750 kPa is highly desirable and 160 GPa for Polycrystalline Silicon. The paper focuses on creating and simulating PDMS cantilever structures of devices that have already been made in the lab, as well as assessing the specific divergence that will be used to determine the precise mass that should be placed on the edge of these micro-structures. To improve the device's sensitivity, a modification to the microcantilever beam's design is unavoidable. The project contains a study of the sensitivity of the microcantilever biosensor to improve the deflection of the microcantilever beam by considering several parameters including the length of the beam, the thickness of the beam, and some shape modifications of the microcantilever beam. The microcantilever beam's length or thickness can be changed to increase or decrease the deflection. The deflection values for two microcantilever beam forms with identical length, thickness, and materials are noted, and it is inferred that shape alteration will increase the microcantilever beam's deflection.
- 24 December 2024
- Published by Springer Nature
- p. 109-124
Large Signal Modelling of GaN HEMTs
- 24 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Low RCS Target Detection with Ground Clutter in Multistatic Airborne Radar
Multistatic radar plays an important role in the detection of low RCS targets. The detection process becomes complicated in multiple target scenarios. Although multistatic radar provides better detection performance, the performance degrades when clutters are present in the received signal. In this paper a space-time adaptive processing technique is implemented to detect multiple targets and cancellation of ground clutters. A transmitted waveform with a large time-bandwidth product is required to detect small targets with long distances in the increased coverage area. So an orthogonal frequency division multiplexing- linear frequency modulated signal is used as the transmitted waveform. A performance comparison has been made for the multistatic radar in terms of probability detection with space-time processing techniques with different transmitter and receiver configurations. The multistatic radar performance is evaluated through simulations and it has been observed that when the number of receiving antenna increases the probability of detection increases.
- 24 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Low RCS Target Detection with Ground Clutter in Multistatic Airborne Radar
Multistatic radar plays an important role in the detection of low RCS targets. The detection process becomes complicated in multiple target scenarios. Although multistatic radar provides better detection performance, the performance degrades when clutters are present in the received signal. In this paper a space-time adaptive processing technique is implemented to detect multiple targets and cancellation of ground clutters. A transmitted waveform with a large time-bandwidth product is required to detect small targets with long distances in the increased coverage area. So an orthogonal frequency division multiplexing- linear frequency modulated signal is used as the transmitted waveform. A performance comparison has been made for the multistatic radar in terms of probability detection with space-time processing techniques with different transmitter and receiver configurations. The multistatic radar performance is evaluated through simulations and it has been observed that when the number of receiving antenna increases the probability of detection increases.
- Open Access
- 6 September 2023
- Published by IntechOpen
A Comparative Analysis of Linear Modulation Schemes in the Presence of FLI in Wireless Optical Systems
In this chapter three optical modulation techniques such as on off keying (OOK), binary phase shift keying (BPSK), differential phase shift keying (DPSK) are evaluated in terms of Q-factor and bit error rate (BER) in order to assess their suitability in typical indoor optical wireless communication. The modulated signals are subjected to additive white Gaussian noise (AWGN) and florescent light interference (FLI) representative of practical scenarios. The received signals are demodulated with and without using matched filter (MF). The BER in both the cases are evaluated through simulation studies using MATLAB and compared for each of the three modulated signals. It has been observed that in each of the demodulation process the rate of reduction of BER is significant when the demodulation is done by using MF.
- 6 September 2023
- Published by IntechOpen
Open AccessA Comparative Analysis of Linear Modulation Schemes in the Presence of FLI in Wireless Optical Systems
In this chapter three optical modulation techniques such as on off keying (OOK), binary phase shift keying (BPSK), differential phase shift keying (DPSK) are evaluated in terms of Q-factor and bit error rate (BER) in order to assess their suitability in typical indoor optical wireless communication. The modulated signals are subjected to additive white Gaussian noise (AWGN) and florescent light interference (FLI) representative of practical scenarios. The received signals are demodulated with and without using matched filter (MF). The BER in both the cases are evaluated through simulation studies using MATLAB and compared for each of the three modulated signals. It has been observed that in each of the demodulation process the rate of reduction of BER is significant when the demodulation is done by using MF.
- 15 December 2021
- Published by CALNESTOR Knowledge Solutions Private Limited
Two Applications of FBG Temperature Sensor for Environmental Safety
Detection and monitoring of temperature in fire sensitive areas, high temperature zones such as underground coal mines and smelting plant applications is a crucial requirement in order to ensure safety of working personnel and to avoid unnecessary damage to life and infrastructure. Underground coal mine fire mostly occurs due to smoldering combustion. The temperature gradient is one of the most important factors for detecting underground fire. Similarly smelting plants as mandated in various stages of aluminium production starting from the mixing stage typically having 160oC-180oC to the alumina electrolysis process that is characterized by about 1000°C.Therefore, detection and subsequent monitoring of temperature change in underground coal mines as well as smelting plants is an important concern. We have proposed and demonstrated a four channel FBG temperature sensor based system, where multiple FBG sensors sense different temperatures and the sensed data is transmitted through a single channel by using wavelength division multiplexing (WDM). At the receiver side a WDM demultiplexer is used to retrieve the originally transmitted signal.The performance of WDM-FBG sensor system has been compared in three different channels such as Optical fiber cable (OFC), Free Space Optics (FSO) and Optical Wireless communication (OWC) channels.
- 15 December 2021
- Published by CALNESTOR Knowledge Solutions Private Limited
Two Applications of FBG Temperature Sensor for Environmental Safety
Detection and monitoring of temperature in fire sensitive areas, high temperature zones such as underground coal mines and smelting plant applications is a crucial requirement in order to ensure safety of working personnel and to avoid unnecessary damage to life and infrastructure. Underground coal mine fire mostly occurs due to smoldering combustion. The temperature gradient is one of the most important factors for detecting underground fire. Similarly smelting plants as mandated in various stages of aluminium production starting from the mixing stage typically having 160oC-180oC to the alumina electrolysis process that is characterized by about 1000°C.Therefore, detection and subsequent monitoring of temperature change in underground coal mines as well as smelting plants is an important concern. We have proposed and demonstrated a four channel FBG temperature sensor based system, where multiple FBG sensors sense different temperatures and the sensed data is transmitted through a single channel by using wavelength division multiplexing (WDM). At the receiver side a WDM demultiplexer is used to retrieve the originally transmitted signal.The performance of WDM-FBG sensor system has been compared in three different channels such as Optical fiber cable (OFC), Free Space Optics (FSO) and Optical Wireless communication (OWC) channels.
- 10 January 1994
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 51 (2) , 245-251
Interchain crosslinking between NBR and polyacrylic rubber and effect on (i) processibility and blend‐morphology
- 10 January 1994
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 51 (2) , 245-251
Interchain crosslinking between NBR and polyacrylic rubber and effect on (i) processibility and blend‐morphology