Kriengsak Limpastan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kriengsak Limpastan has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Chanon Srihagulang
Department of Surgery, Chiang Mai University, Chiang Mai, Thailand
1 shared publication Chumpon Jetjumnong
Neurosurgery Unit, Clinical Surgical Research Center, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
1 shared publication- Chumpon Jetjumnong
Department of Surgery, Chiang Mai University, Chiang Mai, Thailand
1 shared publication - Jirapong Vongsfak
Division of Neurosurgery, Department of Surgery, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
1 shared publication Kittisak Unsrisong
Department of Radiology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
1 shared publicationTanat Vaniyapong
Neurosurgery Unit, Clinical Surgical Research Center, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
1 shared publication
Latest Publications
- Open Access
- 21 June 2024
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 15, 208
Intracranial pressure monitoring for severe traumatic brain injury retrospective study of 273 consecutive patients
Background: Intracranial pressure (ICP) monitoring is essential in severe traumatic brain injury (sTBI) cases; yet, the frequency of high ICP occurrences remains debated. This study presents a 9-year analysis of ICP monitoring using intraventricular catheters among sTBI patients. Methods: A retrospective review of 1760 sTBI patients (Glasgow Coma Score 20 mmHg for 10–15 min during 72 h were categorized with high ICP. Data collected included demographics, computed tomography (CT) findings, intra- and post-operative ICP, and complications. Results: Of 273 patients, 228 were male and 45 females, aged 18–80 (71.30% aged 18–45). Traffic accidents were the primary cause (90.48%). Fifty-two-point 75% experienced high ICP, correlating significantly with subdural hematoma (P < 0.001), intraventricular hemorrhage (P < 0.013), and compressed basal cisterns (P = 0.046) on initial CT. Twenty patients (7.3%) developed meningitis. Lower mortality rates and improved outcomes were observed in the low ICP group across discharge 3-and 6-month follow-ups. Conclusion: Adherence to BTF guidelines yielded a 52.75% high ICP rate. Significant correlations were found between high ICP and specific CT abnormalities. This study underscores the benefits of ICP monitoring in selected sTBI cases, suggesting a need to review criteria for initiating monitoring protocols.
- 21 June 2024
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 15, 208
Open AccessIntracranial pressure monitoring for severe traumatic brain injury retrospective study of 273 consecutive patients
Background: Intracranial pressure (ICP) monitoring is essential in severe traumatic brain injury (sTBI) cases; yet, the frequency of high ICP occurrences remains debated. This study presents a 9-year analysis of ICP monitoring using intraventricular catheters among sTBI patients. Methods: A retrospective review of 1760 sTBI patients (Glasgow Coma Score 20 mmHg for 10–15 min during 72 h were categorized with high ICP. Data collected included demographics, computed tomography (CT) findings, intra- and post-operative ICP, and complications. Results: Of 273 patients, 228 were male and 45 females, aged 18–80 (71.30% aged 18–45). Traffic accidents were the primary cause (90.48%). Fifty-two-point 75% experienced high ICP, correlating significantly with subdural hematoma (P < 0.001), intraventricular hemorrhage (P < 0.013), and compressed basal cisterns (P = 0.046) on initial CT. Twenty patients (7.3%) developed meningitis. Lower mortality rates and improved outcomes were observed in the low ICP group across discharge 3-and 6-month follow-ups. Conclusion: Adherence to BTF guidelines yielded a 52.75% high ICP rate. Significant correlations were found between high ICP and specific CT abnormalities. This study underscores the benefits of ICP monitoring in selected sTBI cases, suggesting a need to review criteria for initiating monitoring protocols.
- Open Access
- 10 December 2022
- Published by Georg Thieme Verlag KG in Asian Journal of Neurosurgery
- Vol. 17 (04) , 614-620
Benefits of Combined MRI Sequences in Meningioma Consistency Prediction: A Prospective Study of 287 Consecutive Patients
Objective Consistency of meningiomas is one of the most important factors affecting the completeness of removal and major risks of meningioma surgery. This study used preoperative magnetic resonance imaging (MRI) sequences in single and in combination to predict meningioma consistency. Methods The prospective study included 287 intracranial meningiomas operated on by five attending neurosurgeons at Chiang Mai University Hospital from July 2012 through June 2020. The intraoperative consistency was categorized in four grades according to the method of surgical removal and intensity of ultrasonic aspirator, then correlated with preoperative tumor signal intensity pattern on MRI including T1-weighted image, T2-weighted image (T2WI), fluid-attenuated inversion recovery (FLAIR), and diffusion-weighted image (DWI), which were described as hypointensity, isointensity, and hyperintensity signals which were blindly interpreted by one neuroradiologist. Results Among 287 patients, 29 were male and 258 female. The ages ranged from 22 to 83 years. A total of 189 tumors were situated in the supratentorial space and 98 were in the middle fossa and infratentorial locations. Note that 125 tumors were found to be of soft consistency (grades 1, 2) and 162 tumors of hard consistency (grades 3, 4). Hyperintensity signals on T2WI, FLAIR, and DWI were significantly associated with soft consistency of meningiomas (relative risk [RR] 2.02, 95% confidence interval [CI] 1.35–3.03, p = 0.001, RR 2.19, 95% CI 1.43–3.35, p < 0.001, and RR 1.47, 95% CI 1.02–2.11, p = 0.037, respectively). Further, chance to be soft consistency significantly increased when two and three hyperintensity signals were combined (RR 2.75, 95% CI 1.62–4.65, p ≤ 0.001, RR 2.79, 95% CI 1.58–4.93, p < 0.001, respectively). Hypointensity signals on T2WI, FLAIR, and DWI were significantly associated with hard consistency of meningiomas (RR 1.82, 95% CI 1.18–2.81, p = 0.007, RR 1.80, 95% CI 1.15–2.83, p = 0.010, RR 1.67, 95% CI 1.07–2.59, p = 0.023, respectively) and chance to be hard consistency significantly increased when three hypointensity signals were combined (RR 1.82, 95% CI 1.11–2.97, p = 0.017). Conclusion T2WI, FLAIR, and DWI hyperintensity signals of the meningiomas was solely significantly associated with soft consistency and predictive value significantly increased when two and three hyperintensity signals were combined. Each of hypointensity signals on T2WI, FLAIR, and DWI was significantly associated with hard consistency of tumors and tendency to be hard consistency significantly increased when hypointensity was found in all three sequences. Article published online: 10 December 2022 © 2022. Asian Congress of Neurological Surgeons. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
- 10 December 2022
- Published by Georg Thieme Verlag KG in Asian Journal of Neurosurgery
- Vol. 17 (04) , 614-620
Open AccessBenefits of Combined MRI Sequences in Meningioma Consistency Prediction: A Prospective Study of 287 Consecutive Patients
Objective Consistency of meningiomas is one of the most important factors affecting the completeness of removal and major risks of meningioma surgery. This study used preoperative magnetic resonance imaging (MRI) sequences in single and in combination to predict meningioma consistency. Methods The prospective study included 287 intracranial meningiomas operated on by five attending neurosurgeons at Chiang Mai University Hospital from July 2012 through June 2020. The intraoperative consistency was categorized in four grades according to the method of surgical removal and intensity of ultrasonic aspirator, then correlated with preoperative tumor signal intensity pattern on MRI including T1-weighted image, T2-weighted image (T2WI), fluid-attenuated inversion recovery (FLAIR), and diffusion-weighted image (DWI), which were described as hypointensity, isointensity, and hyperintensity signals which were blindly interpreted by one neuroradiologist. Results Among 287 patients, 29 were male and 258 female. The ages ranged from 22 to 83 years. A total of 189 tumors were situated in the supratentorial space and 98 were in the middle fossa and infratentorial locations. Note that 125 tumors were found to be of soft consistency (grades 1, 2) and 162 tumors of hard consistency (grades 3, 4). Hyperintensity signals on T2WI, FLAIR, and DWI were significantly associated with soft consistency of meningiomas (relative risk [RR] 2.02, 95% confidence interval [CI] 1.35–3.03, p = 0.001, RR 2.19, 95% CI 1.43–3.35, p < 0.001, and RR 1.47, 95% CI 1.02–2.11, p = 0.037, respectively). Further, chance to be soft consistency significantly increased when two and three hyperintensity signals were combined (RR 2.75, 95% CI 1.62–4.65, p ≤ 0.001, RR 2.79, 95% CI 1.58–4.93, p < 0.001, respectively). Hypointensity signals on T2WI, FLAIR, and DWI were significantly associated with hard consistency of meningiomas (RR 1.82, 95% CI 1.18–2.81, p = 0.007, RR 1.80, 95% CI 1.15–2.83, p = 0.010, RR 1.67, 95% CI 1.07–2.59, p = 0.023, respectively) and chance to be hard consistency significantly increased when three hypointensity signals were combined (RR 1.82, 95% CI 1.11–2.97, p = 0.017). Conclusion T2WI, FLAIR, and DWI hyperintensity signals of the meningiomas was solely significantly associated with soft consistency and predictive value significantly increased when two and three hyperintensity signals were combined. Each of hypointensity signals on T2WI, FLAIR, and DWI was significantly associated with hard consistency of tumors and tendency to be hard consistency significantly increased when hypointensity was found in all three sequences. Article published online: 10 December 2022 © 2022. Asian Congress of Neurological Surgeons. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India