Emmanuel Oluwatobi Badmus
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Emmanuel Oluwatobi Badmus has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Amritanshu Pandey
Department of Electrical and Biomedical Engineering, University of Vermont, Burlington, VT, USA
2 shared publications Dimitrios Stamoulis
1 shared publicationOluwamurewa Precious Odekunle
ETH Zurich: Eidgenossische Technische Hochschule Zurich
1 shared publication- Peng Sang1 shared publication
Samuel Olamide Omole
Federal University Oye-Ekiti
1 shared publication
Latest Publications
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 41 (4) , 2994-3007
Two-Stage Bidirectional Inverter Equivalent Circuit Model for Distribution Grid Steady-State Analysis and Optimization
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 41 (4) , 2994-3007
Two-Stage Bidirectional Inverter Equivalent Circuit Model for Distribution Grid Steady-State Analysis and Optimization
- 26 June 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 262
PowerChain: A verifiable agentic AI system for automating distribution grid analyses
- 26 June 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 262
PowerChain: A verifiable agentic AI system for automating distribution grid analyses
- Open Access
- 12 December 2022
- Published by Springer Nature in Research Square
Design and techno-economic analysis of impact of renewable energy on grid-connected power systems: Kakuri community, Nigeria as a case study.
This research studied the technical, economic, and environmental analysis of system hybridisation of renewable energy systems connected to the conventional grid. The HOMER Pro software analysed the potential of using grid-connected energy systems. The location for the study is the Kakuri in Kaduna, Nigeria, which had an average load of 165.44kWh/day at a 20.46kWpeak. Hybridisation simulations were to showcase the availability of electricity supply and the impact on energy cost. Sensitivity analysis was conducted to understand the impact of the increase in the average yearly solar irradiance, depending on location and weather. The most optimised scenario was the PV/Converter/Grid system which supplied 25kW power, and which PV system supplied 52% of the annual electricity production, which stood at 45,721 kWh/yr. Cost analysis also indicated that the system had a Levelized cost of energy of ₦29.29/kWh and a Net Present Cost (NPC) of ₦28.9 million. 45% NPC made up the PV, while the grid and converter shared 42% and 13%, respectively. The hybrid model was also simulated via MATLAB/SIMULINK software to showcase, analyse and implement the system’s viability for practical scenario usage.
- 12 December 2022
- Published by Springer Nature in Research Square
Open AccessDesign and techno-economic analysis of impact of renewable energy on grid-connected power systems: Kakuri community, Nigeria as a case study.
This research studied the technical, economic, and environmental analysis of system hybridisation of renewable energy systems connected to the conventional grid. The HOMER Pro software analysed the potential of using grid-connected energy systems. The location for the study is the Kakuri in Kaduna, Nigeria, which had an average load of 165.44kWh/day at a 20.46kWpeak. Hybridisation simulations were to showcase the availability of electricity supply and the impact on energy cost. Sensitivity analysis was conducted to understand the impact of the increase in the average yearly solar irradiance, depending on location and weather. The most optimised scenario was the PV/Converter/Grid system which supplied 25kW power, and which PV system supplied 52% of the annual electricity production, which stood at 45,721 kWh/yr. Cost analysis also indicated that the system had a Levelized cost of energy of ₦29.29/kWh and a Net Present Cost (NPC) of ₦28.9 million. 45% NPC made up the PV, while the grid and converter shared 42% and 13%, respectively. The hybrid model was also simulated via MATLAB/SIMULINK software to showcase, analyse and implement the system’s viability for practical scenario usage.