Zhixin Xiong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhixin Xiong has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Long Liang
Institute of Chemical Industry of Forest Products, Chinese Academy of Forestry, Nanjing, China
6 shared publicationsHonghong Wang
College of Light Industry and Food Engineering, Nanjing Forestry University, Nanjing, China
4 shared publicationsYing Wang
College of Information Science and Technology & Artificial Intelligence, Nanjing Forestry University, Nanjing, China
4 shared publicationsYunchao Hu
College of Light Industry and Food Engineering, Nanjing Forestry University, Nanjing 210037, China
4 shared publicationsXianzhi Wu
College of Light Industry and Food Engineering, Nanjing Forestry University, Nanjing, China
3 shared publicationsXinyu Chen
School of Optoelectronic Engineering, Changzhou Institute of Technology, Changzhou, China
3 shared publications
Latest Publications
- 4 June 2026
- Published by Springer Nature in Wood Science and Technology
- Vol. 60 (4) , 67
Model sharing for near-infrared analysis of lignin content in pulpwood based on hybrid calibration combined with LSTM algorithm
- 4 June 2026
- Published by Springer Nature in Wood Science and Technology
- Vol. 60 (4) , 67
Model sharing for near-infrared analysis of lignin content in pulpwood based on hybrid calibration combined with LSTM algorithm
- 14 January 2025
- Published by Elsevier in Journal of Chromatography A
- Vol. 1743, 465683
Analysis of volatile compounds and vintage discrimination of raw Pu-erh tea based on GC-IMS and GC–MS combined with data fusion
- 14 January 2025
- Published by Elsevier in Journal of Chromatography A
- Vol. 1743, 465683
Analysis of volatile compounds and vintage discrimination of raw Pu-erh tea based on GC-IMS and GC–MS combined with data fusion
- 4 April 2024
- Published by Springer Nature in Analytical Sciences
- Vol. 40 (7) , 1261-1268
Pulpwood holocellulose model transfer based on screening with consistent and stable signals algorithm
In this study, in order to realize the sharing of the near-infrared analysis model of holocellulose between three spectral instruments of the same type, 84 pulp samples and their content of holocellulose were taken as the research objects. The effects of 10 pre-processing methods, such as 1st derivative (D1st), 2nd derivative (D2nd), multiplicative scatter correction (MSC), standard normal variable transformation (SNV), autoscaling, normalization, mean centering and pairwise combination, on the transfer effect of the stable wavelength selected by screening wavelengths with consistent and stable signals (SWCSS) were discussed. The results showed that the model established by the wavelength selected by the SWCSS algorithm after the autoscaling pre-processing method had the best analysis effect on the two target samples. Root mean square error of prediction (RMSEP) decreased from 2.4769 and 2.3119 before the model transfer to 1.2563 and 1.2384, respectively. Compared with the full-spectrum model, the value of AIC decreased from 3209.83 to 942.82. Therefore, the autoscaling pre-processing method combined with SWCSS algorithm can significantly improve the accuracy and efficiency of model transfer and provide help for the application of SWCSS algorithm in the rapid determination of pulp properties by near-infrared spectroscopy (NIRS). Graphical abstract
- 4 April 2024
- Published by Springer Nature in Analytical Sciences
- Vol. 40 (7) , 1261-1268
Pulpwood holocellulose model transfer based on screening with consistent and stable signals algorithm
In this study, in order to realize the sharing of the near-infrared analysis model of holocellulose between three spectral instruments of the same type, 84 pulp samples and their content of holocellulose were taken as the research objects. The effects of 10 pre-processing methods, such as 1st derivative (D1st), 2nd derivative (D2nd), multiplicative scatter correction (MSC), standard normal variable transformation (SNV), autoscaling, normalization, mean centering and pairwise combination, on the transfer effect of the stable wavelength selected by screening wavelengths with consistent and stable signals (SWCSS) were discussed. The results showed that the model established by the wavelength selected by the SWCSS algorithm after the autoscaling pre-processing method had the best analysis effect on the two target samples. Root mean square error of prediction (RMSEP) decreased from 2.4769 and 2.3119 before the model transfer to 1.2563 and 1.2384, respectively. Compared with the full-spectrum model, the value of AIC decreased from 3209.83 to 942.82. Therefore, the autoscaling pre-processing method combined with SWCSS algorithm can significantly improve the accuracy and efficiency of model transfer and provide help for the application of SWCSS algorithm in the rapid determination of pulp properties by near-infrared spectroscopy (NIRS). Graphical abstract
- 3 February 2024
- Published by Springer Nature in Journal of Materials Science
- Vol. 59 (7) , 3191-3204
A model transfer strategy based on screening stable wavelength for quantitative analysis of holocellulose and lignin content distribution in pulpwood
- 3 February 2024
- Published by Springer Nature in Journal of Materials Science
- Vol. 59 (7) , 3191-3204
A model transfer strategy based on screening stable wavelength for quantitative analysis of holocellulose and lignin content distribution in pulpwood
- Open Access
- 1 January 2023
- Published by Tech Science Press in Journal of Renewable Materials
- Vol. 11 (6) , 2713-2727
Application of Wavelength Selection Combined with DS Algorithm for Model Transfer between NIR Instruments
This study aims to realize the sharing of near-infrared analysis models of lignin and holocellulose content in pulp wood on two different batches of spectrometers and proposes a combined algorithm of SPA-DS, MCUVE-DS and SiPLS-DS. The Successive Projection Algorithm (SPA), the Monte-Carlo of Uninformative Variable Elimination (MCUVE) and the Synergy Interval Partial Least Squares (SiPLS) algorithms are respectively used to reduce the adverse effects of redundant information in the transmission process of the full spectrum DS algorithm model. These three algorithms can improve model transfer accuracy and efficiency and reduce the manpower and material consumption required for modeling. These results show that the modeling effects of the characteristic wavelengths screened by the SPA, MCUVE and SiPLS algorithms are all greatly improved compared with the full-spectrum modeling, in which the SPA-PLS result in the best prediction with RPDs above 6.5 for both components. The three wavelength selection methods combined with the DS algorithm are used to transfer the models of the two instruments. Among them, the MCUVE combined with the DS algorithm has the best transfer effect. After the model transfer, the RMSEP of lignin is 0.701, and the RMSEP of holocellulose is 0.839, which was improved significantly than the full-spectrum model transfer of 0.759 and 0.918.
- 1 January 2023
- Published by Tech Science Press in Journal of Renewable Materials
- Vol. 11 (6) , 2713-2727
Open AccessApplication of Wavelength Selection Combined with DS Algorithm for Model Transfer between NIR Instruments
This study aims to realize the sharing of near-infrared analysis models of lignin and holocellulose content in pulp wood on two different batches of spectrometers and proposes a combined algorithm of SPA-DS, MCUVE-DS and SiPLS-DS. The Successive Projection Algorithm (SPA), the Monte-Carlo of Uninformative Variable Elimination (MCUVE) and the Synergy Interval Partial Least Squares (SiPLS) algorithms are respectively used to reduce the adverse effects of redundant information in the transmission process of the full spectrum DS algorithm model. These three algorithms can improve model transfer accuracy and efficiency and reduce the manpower and material consumption required for modeling. These results show that the modeling effects of the characteristic wavelengths screened by the SPA, MCUVE and SiPLS algorithms are all greatly improved compared with the full-spectrum modeling, in which the SPA-PLS result in the best prediction with RPDs above 6.5 for both components. The three wavelength selection methods combined with the DS algorithm are used to transfer the models of the two instruments. Among them, the MCUVE combined with the DS algorithm has the best transfer effect. After the model transfer, the RMSEP of lignin is 0.701, and the RMSEP of holocellulose is 0.839, which was improved significantly than the full-spectrum model transfer of 0.759 and 0.918.
- 6 December 2022
- Published by Taylor & Francis in Wood Material Science & Engineering
- Vol. 18 (4) , 1405-1414
Application of wavelength selection strategy based on SWCSS-UVE algorithm in improving model transfer for near infrared analysis of holocellulose and lignin
- 6 December 2022
- Published by Taylor & Francis in Wood Material Science & Engineering
- Vol. 18 (4) , 1405-1414
Application of wavelength selection strategy based on SWCSS-UVE algorithm in improving model transfer for near infrared analysis of holocellulose and lignin
- Open Access
- 20 October 2022
- Published by Springer Nature in Research Square
Application of SWSRA-DS Algorithm in Improving the Model Transfer for Near Infrared Analysis of Pulpwood Holocellulose
The SWSRA-DS combined algorithm was proposed with the goal of sharing the NIR analysis model of the holocellulose content of pulpwood on three different types of spectroscopic instruments. That was, the Screening wavelengths based on spectrum ratio analysis (SWSRA) algorithm was used to select the wavelengths with good stability and consistency. These important wavelength variables, which were insensitive to the measured sample parameters, can reduce the differences in sample information response by different instruments or measurement conditions. Then the systematic errors that still existed after the SWSRA method calibration were further calibrated using the Direct Standardization (DS) method on the basis of these wavelengths. This combined algorithm can improve the generalizability of the master model, reduce the spectrum matrix dimension, and make the model transfer more stabilized and simply. The results show that the SWSRA-DS combined algorithm was able to reduce the RMSEP of the master model to predict the holocellulose content of samples measured on the target 1 and target 2 instruments from 2.0114 and 9.4518 to 0.9641 and 1.0798, respectively. This result was compared with the calibration results of SWSRA and DS alone and the commonly used PDS and S/B model transfer algorithms to transfer performance was significantly improved, which provides a new idea for the sharing of NIR analysis models among different types of spectroscopic instruments.
- 20 October 2022
- Published by Springer Nature in Research Square
Open AccessApplication of SWSRA-DS Algorithm in Improving the Model Transfer for Near Infrared Analysis of Pulpwood Holocellulose
The SWSRA-DS combined algorithm was proposed with the goal of sharing the NIR analysis model of the holocellulose content of pulpwood on three different types of spectroscopic instruments. That was, the Screening wavelengths based on spectrum ratio analysis (SWSRA) algorithm was used to select the wavelengths with good stability and consistency. These important wavelength variables, which were insensitive to the measured sample parameters, can reduce the differences in sample information response by different instruments or measurement conditions. Then the systematic errors that still existed after the SWSRA method calibration were further calibrated using the Direct Standardization (DS) method on the basis of these wavelengths. This combined algorithm can improve the generalizability of the master model, reduce the spectrum matrix dimension, and make the model transfer more stabilized and simply. The results show that the SWSRA-DS combined algorithm was able to reduce the RMSEP of the master model to predict the holocellulose content of samples measured on the target 1 and target 2 instruments from 2.0114 and 9.4518 to 0.9641 and 1.0798, respectively. This result was compared with the calibration results of SWSRA and DS alone and the commonly used PDS and S/B model transfer algorithms to transfer performance was significantly improved, which provides a new idea for the sharing of NIR analysis models among different types of spectroscopic instruments.
- 3 October 2022
- Published by BioResources in BioResources
- Vol. 17 (4) , 6476-6489
Transfer strategy for near infrared analysis model of holocellulose and lignin based on improved slope/bias algorithm
Model transfer techniques in near infrared spectroscopy are important for avoiding duplicate modeling, sharing samples and data resources, and reducing the human and material consumption required for modeling. Use of the slope/bias correction algorithm (S/B) based on screening wavelengths with consistent and stable signals (SWCSS) for model transfer is a new strategy. To enable sharing of near infrared analysis models of pulp holocellulose and lignin content in two different types of spectroscopic instruments, a combined SWCSS-S/B algorithm was proposed. The stable and consistent wavelengths between the spectroscopic instruments screened by the SWCSS method reduced the differences between the instruments, thereby improving the universality and transmission accuracy of the S/B method. The SWCSS-S/B based model transfer method reduced the predicted standard deviation RMSEP of holocellulose and lignin contents of the samples measured on the target spectrometer of the from 5.4686 and 7.6823 to 1.2133 and 1.3494, respectively. This result showed a significant improvement in the transfer effect compared to the SWCSS and S/B correction results alone, and the prediction of holocellulose was better than that of the prediction effect of lignin. The method has fewer wavelength variables involved in model transfer, fast transfer speed, and high prediction accuracy, which provides a new solution for the wide application of NIR analytical models.
- 3 October 2022
- Published by BioResources in BioResources
- Vol. 17 (4) , 6476-6489
Transfer strategy for near infrared analysis model of holocellulose and lignin based on improved slope/bias algorithm
Model transfer techniques in near infrared spectroscopy are important for avoiding duplicate modeling, sharing samples and data resources, and reducing the human and material consumption required for modeling. Use of the slope/bias correction algorithm (S/B) based on screening wavelengths with consistent and stable signals (SWCSS) for model transfer is a new strategy. To enable sharing of near infrared analysis models of pulp holocellulose and lignin content in two different types of spectroscopic instruments, a combined SWCSS-S/B algorithm was proposed. The stable and consistent wavelengths between the spectroscopic instruments screened by the SWCSS method reduced the differences between the instruments, thereby improving the universality and transmission accuracy of the S/B method. The SWCSS-S/B based model transfer method reduced the predicted standard deviation RMSEP of holocellulose and lignin contents of the samples measured on the target spectrometer of the from 5.4686 and 7.6823 to 1.2133 and 1.3494, respectively. This result showed a significant improvement in the transfer effect compared to the SWCSS and S/B correction results alone, and the prediction of holocellulose was better than that of the prediction effect of lignin. The method has fewer wavelength variables involved in model transfer, fast transfer speed, and high prediction accuracy, which provides a new solution for the wide application of NIR analytical models.