Hai-Yan Feng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hai-Yan Feng has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Liangshuai Liu
State Grid Hebei Electric Power Research Institute, Shijiazhuang, China
2 shared publications - Yanpeng Ji
State grid Hebei electric power research institute, Shijiazhuang 050000, China
2 shared publications - Jia-Qi Du
State grid Hebei electric power research institute, Shijiazhuang 050000, China
1 shared publication - Jianli Zhao
State Grid Hebei Electric Power Research Institute, Shijiazhuang 050021, China
1 shared publication - Shaokang Zhao
State Grid Hebei Electric Power Co., Ltd., Shijiazhuang 050031, China
1 shared publication - Xia Fang
School of Mechanical Engineering, Sichuan University, Chengdu, China
1 shared publication
Latest Publications
- Open Access
Dual-Branch Discriminative Transmission Line Bolt Image Classification Based on Contrastive Learning
The classification of transmission tower bolt images faces challenges such as class imbalance, sample scarcity, and the low pixel proportion of pins. Traditional classification methods exhibit poor performance in identifying key categories with small proportions, fail to leverage the correlation between transmission line fittings and bolts, and suffer from severe false positive issues. This study proposes a novel approach that dynamically integrates two sampling strategies to address the class imbalance problem while incorporating contrastive learning and category labels to enhance the discrimination of easily confused samples. Additionally, an auxiliary branch discrimination mechanism effectively exploits the correlation between fittings and bolts and, combined with a threshold-based decision process, significantly reduces the false positive rate (by 3.74%). The experimental results demonstrate that, compared to the baseline SimCLR framework with ResNet18, the proposed method improves accuracy (Acc) by 10.22%, reduces the false alarm rate by 5%, and significantly enhances classification reliability in transmission line inspections, thereby mitigating unnecessary human resource consumption.
Open AccessDual-Branch Discriminative Transmission Line Bolt Image Classification Based on Contrastive Learning
The classification of transmission tower bolt images faces challenges such as class imbalance, sample scarcity, and the low pixel proportion of pins. Traditional classification methods exhibit poor performance in identifying key categories with small proportions, fail to leverage the correlation between transmission line fittings and bolts, and suffer from severe false positive issues. This study proposes a novel approach that dynamically integrates two sampling strategies to address the class imbalance problem while incorporating contrastive learning and category labels to enhance the discrimination of easily confused samples. Additionally, an auxiliary branch discrimination mechanism effectively exploits the correlation between fittings and bolts and, combined with a threshold-based decision process, significantly reduces the false positive rate (by 3.74%). The experimental results demonstrate that, compared to the baseline SimCLR framework with ResNet18, the proposed method improves accuracy (Acc) by 10.22%, reduces the false alarm rate by 5%, and significantly enhances classification reliability in transmission line inspections, thereby mitigating unnecessary human resource consumption.
- Open Access
A New Orientation Detection Method for Tilting Insulators Incorporating Angle Regression and Priori Constraints
The accurate detection of insulators is an important prerequisite for insulator fault diagnosis. To solve the problem of background interference and overlap caused by the axis-aligned bounding boxes in the tilting insulator detection tasks, we construct an improved detection architecture according to the scale and tilt features of the insulators from several perspectives, such as bounding box representation, loss function, and anchor box construction. A new orientation detection method for tilting insulators based on angle regression and priori constraints is put forward in this paper. Ablation tests and comparative validation tests were conducted on a self-built aerial insulator image dataset. The results show that the detection accuracy of our model was increased by 7.98% compared with that of the baseline, and the overall detection accuracy reached 82.33%. Moreover, the detection effect of our method was better than that of the YOLOv5 detection model and other orientation detection models. Our model provides a new idea for the accurate orientation detection of insulators.
Open AccessA New Orientation Detection Method for Tilting Insulators Incorporating Angle Regression and Priori Constraints
The accurate detection of insulators is an important prerequisite for insulator fault diagnosis. To solve the problem of background interference and overlap caused by the axis-aligned bounding boxes in the tilting insulator detection tasks, we construct an improved detection architecture according to the scale and tilt features of the insulators from several perspectives, such as bounding box representation, loss function, and anchor box construction. A new orientation detection method for tilting insulators based on angle regression and priori constraints is put forward in this paper. Ablation tests and comparative validation tests were conducted on a self-built aerial insulator image dataset. The results show that the detection accuracy of our model was increased by 7.98% compared with that of the baseline, and the overall detection accuracy reached 82.33%. Moreover, the detection effect of our method was better than that of the YOLOv5 detection model and other orientation detection models. Our model provides a new idea for the accurate orientation detection of insulators.