Ludvik Alkhoury
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ludvik Alkhoury has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Moshe Kam
Department of Electrical and Computer Engineering, Newark College of Engineering, New Jersey Institute of Technology, Newark, NJ 07102, USA
6 shared publications - Nicholas Jeremy Hill
National Center for Adaptive Neurotechnologies, Albany Stratton VA Medical Center Albany, 113 Holland Ave, Albany, New York, 12208, UNITED STATES
4 shared publications - Atilla Sivri
Department of Electrical and Computer Engineering, Newark College of Engineering, New Jersey Institute of Technology, Newark, NJ 07102, USA
2 shared publications Barry S. Shender
Naval Air Warfare Center Aircraft Division,Human Systems Department,Patuxent River,MD,USA,20670
2 shared publicationsChizhong Wang
Newark College of Engineering, New Jersey Institute of Technology,Department of Electrical and Computer Engineering,New Jersey,USA,07102
2 shared publications- Giacomo Scanavini
Yale University
2 shared publications
Latest Publications
- Open Access
- 9 June 2026
- Published by Elsevier in SSRN Electronic Journal
pycasa: A Python toolkit for computer-assisted semen analysis
Computer-assisted semen analysis (CASA) systems are used in specialized laboratories to measure the kinematic parameters that characterize sperm motility. These systems are typically proprietary, costly, and closed, which makes their underlying methods difficult to access, tune, reprogram, reproduce, or compare. We introduce pycasa, an open-source Python toolkit that accepts semen time-lapse videos as input and outputs sperm cell detections, trajectories, motility parameters, and visualizations, providing the fundamental functionality a CASA system relies on: video loading, video preprocessing, sperm cell detection and tracking, motility parameter calculation, and visualization. Rather than prescribing a single fixed workflow, pycasa integrates a range of state-of-the-art methods in each module, including Digital Washing and You Only Look Once (YOLO) for detection, and Simple Online and Realtime Tracking (SORT) and the Joint Probabilistic Data Association Filter (JPDAF) for tracking. To support out-of-the-box use, the toolkit provides access to a recording from the Human Semen Time-Lapse Imaging (HSTLI) dataset, a publicly available collection of annotated semen videos, without requiring any local data collection. pycasa is designed to be flexible, allowing users to combine and configure its methods freely to suit the needs of their application.
- 9 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open Accesspycasa: A Python toolkit for computer-assisted semen analysis
Computer-assisted semen analysis (CASA) systems are used in specialized laboratories to measure the kinematic parameters that characterize sperm motility. These systems are typically proprietary, costly, and closed, which makes their underlying methods difficult to access, tune, reprogram, reproduce, or compare. We introduce pycasa, an open-source Python toolkit that accepts semen time-lapse videos as input and outputs sperm cell detections, trajectories, motility parameters, and visualizations, providing the fundamental functionality a CASA system relies on: video loading, video preprocessing, sperm cell detection and tracking, motility parameter calculation, and visualization. Rather than prescribing a single fixed workflow, pycasa integrates a range of state-of-the-art methods in each module, including Digital Washing and You Only Look Once (YOLO) for detection, and Simple Online and Realtime Tracking (SORT) and the Joint Probabilistic Data Association Filter (JPDAF) for tracking. To support out-of-the-box use, the toolkit provides access to a recording from the Human Semen Time-Lapse Imaging (HSTLI) dataset, a publicly available collection of annotated semen videos, without requiring any local data collection. pycasa is designed to be flexible, allowing users to combine and configure its methods freely to suit the needs of their application.
- Open Access
- 12 May 2026
- Published by Elsevier in SSRN Electronic Journal
TinZr: A Compact Wireless ESP32-C3 Platform for Multi-modal Physiological Data Acquisition
Microcontrollers have become central to wearable technologies. As these systems continue to evolve, both form factor and functional integration have become critical design considerations. In this study, we present TinZr, a compact, wireless, and open-source controller based on the ESP32-C3 microcontroller. The TinZr integrates an inertial measurement unit (IMU), an onboard battery management circuit, Wi-Fi and Bluetooth Low Energy, a microSD card reader, and multiple GPIOs supporting digital, analog, I2C, SPI, and UART interfaces. The complete system measures only 25 mm × 25 mm, making it well-suited for wearable applications. All production files, including PCB design, firmware, and a 3D model of a wearable enclosure, are publicly available. Two primary use cases for TinZr are demonstrated: (a) multi-device communication and coordination, and (b) wireless IMU data acquisition. The TinZr supports both real-time data streaming via Wi-Fi/BLE and local logging to a microSD card. Local streaming makes the TinZr suitable for extended research experiments and field studies where continuous wireless connectivity may not be available. An accompanying Arduino library, TinZrConnect, is provided to facilitate programming and integration with existing systems. Overall, the combination of compact design, wireless flexibility, and open-source accessibility, makes TinZr a versatile solution for various sensing applications.
- 12 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessTinZr: A Compact Wireless ESP32-C3 Platform for Multi-modal Physiological Data Acquisition
Microcontrollers have become central to wearable technologies. As these systems continue to evolve, both form factor and functional integration have become critical design considerations. In this study, we present TinZr, a compact, wireless, and open-source controller based on the ESP32-C3 microcontroller. The TinZr integrates an inertial measurement unit (IMU), an onboard battery management circuit, Wi-Fi and Bluetooth Low Energy, a microSD card reader, and multiple GPIOs supporting digital, analog, I2C, SPI, and UART interfaces. The complete system measures only 25 mm × 25 mm, making it well-suited for wearable applications. All production files, including PCB design, firmware, and a 3D model of a wearable enclosure, are publicly available. Two primary use cases for TinZr are demonstrated: (a) multi-device communication and coordination, and (b) wireless IMU data acquisition. The TinZr supports both real-time data streaming via Wi-Fi/BLE and local logging to a microSD card. Local streaming makes the TinZr suitable for extended research experiments and field studies where continuous wireless connectivity may not be available. An accompanying Arduino library, TinZrConnect, is provided to facilitate programming and integration with existing systems. Overall, the combination of compact design, wireless flexibility, and open-source accessibility, makes TinZr a versatile solution for various sensing applications.
- Open Access
- 30 March 2026
- Published by Elsevier in SSRN Electronic Journal
TinZr: A Compact Wireless ESP32-C3 Platform for Multi-modal Physiological Data Acquisition
Microcontrollers have become central to wearable technologies. As these systems continue to evolve, both form factor and functional integration have become critical design considerations. In this study, we present TinZr, a compact, wireless, and open-source controller based on the ESP32-C3 microcontroller. The TinZr integrates an inertial measurement unit (IMU), an onboard battery management circuit, Wi-Fi and Bluetooth Low Energy, a microSD card reader, and multiple GPIOs supporting digital, analog, I 2 C, SPI, and UART interfaces. The complete system measures only 25 mm × 25 mm, making it well-suited for wearable applications. All production files, including PCB design, firmware, and a 3D model of a wearable enclosure, are publicly available. Two primary use cases for TinZr are demonstrated: (a) multi-device communication and coordination, and (b) wireless IMU data acquisition. The TinZr supports both real-time data streaming via Wi-Fi/BLE and local logging to a microSD card. Local streaming makes the TinZr suitable for extended research experiments and field studies where continuous wireless connectivity may not be available. An accompanying Arduino library, TinZrConnect, is provided to facilitate programming and integration with existing systems. Overall, the combination of compact design, wireless flexibility, and open-source accessibility, makes TinZr a versatile solution for various sensing applications.
- 30 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessTinZr: A Compact Wireless ESP32-C3 Platform for Multi-modal Physiological Data Acquisition
Microcontrollers have become central to wearable technologies. As these systems continue to evolve, both form factor and functional integration have become critical design considerations. In this study, we present TinZr, a compact, wireless, and open-source controller based on the ESP32-C3 microcontroller. The TinZr integrates an inertial measurement unit (IMU), an onboard battery management circuit, Wi-Fi and Bluetooth Low Energy, a microSD card reader, and multiple GPIOs supporting digital, analog, I 2 C, SPI, and UART interfaces. The complete system measures only 25 mm × 25 mm, making it well-suited for wearable applications. All production files, including PCB design, firmware, and a 3D model of a wearable enclosure, are publicly available. Two primary use cases for TinZr are demonstrated: (a) multi-device communication and coordination, and (b) wireless IMU data acquisition. The TinZr supports both real-time data streaming via Wi-Fi/BLE and local logging to a microSD card. Local streaming makes the TinZr suitable for extended research experiments and field studies where continuous wireless connectivity may not be available. An accompanying Arduino library, TinZrConnect, is provided to facilitate programming and integration with existing systems. Overall, the combination of compact design, wireless flexibility, and open-source accessibility, makes TinZr a versatile solution for various sensing applications.
- Open Access
- 1 June 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (3) , 036048
Artifact-reference multivariate backward regression (ARMBR): a novel method for EEG blink artifact removal with minimal data requirements
Objective . We present a novel and lightweight method that removes ocular artifacts from electroencephalography (EEG) recordings while demanding minimal training data. Approach . A robust, cross-validated thresholding procedure automatically detects the times at which eye blinks occur, then a linear scalp projection is estimated by regressing a simplified time-locked reference signal against the multi-channel EEG. Main results . Performance was compared against four commonly-used and readily available blink removal methods: signal subspace projection and forward regression (Reg) from the MNE toolbox, EEGLab’s independent component analysis (ICA) combined with ICLabel for automated component identification, and Artifact Subspace Reconstruction (ASR) Python implementation compatible with MNE. On semi-synthetic blink-contaminated EEG data, our method exhibited better reconstruction of the ground truth than the two MNE native methods, and comparable (or better in some scenarios) performance to ASR algorithm and ICA+IClabel. We also examined a real EEG dataset from 16 human participants, where the ground truth was unknown. Our method affected contaminated channels in blink intervals more than the two MNE native methods and ASR, while having a smaller impact on non-blink intervals, uncontaminated channels, and higher-frequency amplitudes, than the two MNE methods; its performance was again similar to ICA+ICLabel. On a second real dataset from 42 human participants, we showed that ARMBR removed the unwanted blink artifacts while successfully preserving the desired event-related-potential signals. Significance . The proposed algorithm exhibited comparable, and in some scenarios better performance relative to readily-available implementations of other widely-used methods. Another feature of our method is its potential as method for online applications. Therefore, it stands to make valuable contributions towards the automation of neural-engineering technologies and their translation from laboratory to clinical and other real-world usage.
- 1 June 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (3) , 036048
Open AccessArtifact-reference multivariate backward regression (ARMBR): a novel method for EEG blink artifact removal with minimal data requirements
Objective . We present a novel and lightweight method that removes ocular artifacts from electroencephalography (EEG) recordings while demanding minimal training data. Approach . A robust, cross-validated thresholding procedure automatically detects the times at which eye blinks occur, then a linear scalp projection is estimated by regressing a simplified time-locked reference signal against the multi-channel EEG. Main results . Performance was compared against four commonly-used and readily available blink removal methods: signal subspace projection and forward regression (Reg) from the MNE toolbox, EEGLab’s independent component analysis (ICA) combined with ICLabel for automated component identification, and Artifact Subspace Reconstruction (ASR) Python implementation compatible with MNE. On semi-synthetic blink-contaminated EEG data, our method exhibited better reconstruction of the ground truth than the two MNE native methods, and comparable (or better in some scenarios) performance to ASR algorithm and ICA+IClabel. We also examined a real EEG dataset from 16 human participants, where the ground truth was unknown. Our method affected contaminated channels in blink intervals more than the two MNE native methods and ASR, while having a smaller impact on non-blink intervals, uncontaminated channels, and higher-frequency amplitudes, than the two MNE methods; its performance was again similar to ICA+ICLabel. On a second real dataset from 42 human participants, we showed that ARMBR removed the unwanted blink artifacts while successfully preserving the desired event-related-potential signals. Significance . The proposed algorithm exhibited comparable, and in some scenarios better performance relative to readily-available implementations of other widely-used methods. Another feature of our method is its potential as method for online applications. Therefore, it stands to make valuable contributions towards the automation of neural-engineering technologies and their translation from laboratory to clinical and other real-world usage.
- Open Access
Dual Wavelength Photoplethysmography Framework for Heart Rate Calculation
The quality of heart rate (HR) measurements extracted from human photoplethysmography (PPG) signals are known to deteriorate under appreciable human motion. Auxiliary signals, such as accelerometer readings, are usually employed to detect and suppress motion artifacts. A 2019 study by Yifan Zhang and his coinvestigatorsused the noise components extracted from an infrared PPG signal to denoise a green PPG signal from which HR was extracted. Until now, this approach was only tested on “micro-motion” such as finger tapping. In this study, we extend this technique to allow accurate calculation of HR under high-intensity full-body repetitive “macro-motion”. Our Dual Wavelength (DWL) framework was tested on PPG data collected from 14 human participants while running on a treadmill. The DWL method showed the following attributes: (1) it performed well under high-intensity full-body repetitive “macro-motion”, exhibiting high accuracy in the presence of motion artifacts (as compared to the leading accelerometer-dependent HR calculation techniques TROIKA and JOSS); (2) it used only PPG signals; auxiliary signals such as accelerometer signals were not needed; and (3) it was computationally efficient, hence implementable in wearable devices. DWL yielded a Mean Absolute Error of 1.22|0.57 BPM, Mean Absolute Error Percentage of 0.95|0.38%, and performance index (which is the frequency, in percent, of obtaining an HR estimate that is within ±5 BPM of the HR ground truth) of 95.88|4.9%. Moreover, DWL yielded a short computation period of 3.0|0.3 s to process a 360-second-long run.Open AccessDual Wavelength Photoplethysmography Framework for Heart Rate Calculation
The quality of heart rate (HR) measurements extracted from human photoplethysmography (PPG) signals are known to deteriorate under appreciable human motion. Auxiliary signals, such as accelerometer readings, are usually employed to detect and suppress motion artifacts. A 2019 study by Yifan Zhang and his coinvestigatorsused the noise components extracted from an infrared PPG signal to denoise a green PPG signal from which HR was extracted. Until now, this approach was only tested on “micro-motion” such as finger tapping. In this study, we extend this technique to allow accurate calculation of HR under high-intensity full-body repetitive “macro-motion”. Our Dual Wavelength (DWL) framework was tested on PPG data collected from 14 human participants while running on a treadmill. The DWL method showed the following attributes: (1) it performed well under high-intensity full-body repetitive “macro-motion”, exhibiting high accuracy in the presence of motion artifacts (as compared to the leading accelerometer-dependent HR calculation techniques TROIKA and JOSS); (2) it used only PPG signals; auxiliary signals such as accelerometer signals were not needed; and (3) it was computationally efficient, hence implementable in wearable devices. DWL yielded a Mean Absolute Error of 1.22|0.57 BPM, Mean Absolute Error Percentage of 0.95|0.38%, and performance index (which is the frequency, in percent, of obtaining an HR estimate that is within ±5 BPM of the HR ground truth) of 95.88|4.9%. Moreover, DWL yielded a short computation period of 3.0|0.3 s to process a 360-second-long run. - Open Access
- 7 October 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-17
An assessment tool for computer-assisted semen analysis (CASA) algorithms
Computer-Assisted Semen Analysis (CASA) enables reliable analysis of semen images, and is designed to process large number of images with high consistency, accuracy, and repeatability. Design and testing of CASA algorithms can be accelerated greatly if reliable simulations of semen images under a variety of conditions and sample quality modes are available. Using life-like simulation of semen images can quantify the performance of existing and proposed CASA algorithms, since the parameters of the simulated image are known and controllable. We present simulation models for sperm cell image and swimming modes observed in real 2D (top-down) images of sperm cells in laboratory specimen. The models simulate human sperm using four (4) types of swimming, namely linear mean, circular, hyperactive, and immotile (or dead). The simulation models are used in studying algorithms for segmentation, localization, and tracking of sperm cells. Several segmentation and localization algorithms were tested under varying levels of noise, and then compared using precision, recall, and the optimal subpattern assignment (OSPA) metric. Images of real human semen sample were used to validate the segmentation and localization observations obtained from simulations. An example is given of sperm cell tracking on simulated semen images of cells using the different tracking algorithms (nearest neighbor (NN), global nearest neighbor (GNN), probabilistic data association filter (PDAF), and joint probabilistic data association filter (JPDAF)). Tracking performance was evaluated through multi-object tracking precision (MOTP) and multi-object tracking accuracy (MOTA). Simulation models enable objective assessments of semen image processing algorithms. We demonstrate the use of a new simulation tool to assess and compare segmentation, localization, and tracking methods. The simulation software allows testing along a large spectrum of parameter values that control the appearance and behavior of simulated semen images. Users can generate scenarios of different characteristics and assess the effectiveness of different CASA algorithms in these environments. The simulation was used to assess and compare algorithms for segmentation and tracking of sperm cells in semen images.
- 7 October 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-17
Open AccessAn assessment tool for computer-assisted semen analysis (CASA) algorithms
Computer-Assisted Semen Analysis (CASA) enables reliable analysis of semen images, and is designed to process large number of images with high consistency, accuracy, and repeatability. Design and testing of CASA algorithms can be accelerated greatly if reliable simulations of semen images under a variety of conditions and sample quality modes are available. Using life-like simulation of semen images can quantify the performance of existing and proposed CASA algorithms, since the parameters of the simulated image are known and controllable. We present simulation models for sperm cell image and swimming modes observed in real 2D (top-down) images of sperm cells in laboratory specimen. The models simulate human sperm using four (4) types of swimming, namely linear mean, circular, hyperactive, and immotile (or dead). The simulation models are used in studying algorithms for segmentation, localization, and tracking of sperm cells. Several segmentation and localization algorithms were tested under varying levels of noise, and then compared using precision, recall, and the optimal subpattern assignment (OSPA) metric. Images of real human semen sample were used to validate the segmentation and localization observations obtained from simulations. An example is given of sperm cell tracking on simulated semen images of cells using the different tracking algorithms (nearest neighbor (NN), global nearest neighbor (GNN), probabilistic data association filter (PDAF), and joint probabilistic data association filter (JPDAF)). Tracking performance was evaluated through multi-object tracking precision (MOTP) and multi-object tracking accuracy (MOTA). Simulation models enable objective assessments of semen image processing algorithms. We demonstrate the use of a new simulation tool to assess and compare segmentation, localization, and tracking methods. The simulation software allows testing along a large spectrum of parameter values that control the appearance and behavior of simulated semen images. Users can generate scenarios of different characteristics and assess the effectiveness of different CASA algorithms in these environments. The simulation was used to assess and compare algorithms for segmentation and tracking of sperm cells in semen images.
- 21 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 5, 46-51
Mitigation of Motion Artifacts in Pulse Oximetry through Redundant Sensors
Photoplethysmography (PPG) signals are used in pulse oximetry to calculate peripheral capillary oxygen saturation $(SpO_{2})$ levels. It is well known that the accuracy of the calculated $SpO_{2}$ is susceptible to motion noise. Using field data collected from human subjects during rest and while exhibiting medium to high-intensity physical exercises, we show how sensor redundancy can mitigate motion effects by employing two channels of red and infrared PPG signals. We demonstrate the advantage of redundancy using two $SpO_{2}$ calculation methods. These methods are widely used “Red over Infrared” (RoI) method and the Discrete Saturation Transform (DST) algorithm both, assisted by pre-filtering by a heart-rate tuned comb filter. The data were collected from individuals at rest and while exercising. $SpO_{2}$ levels are calculated for two channels, each using a red and an infrared PPG signal. We integrated the $SpO_{2}$ computed from the two channels with a Kalman filter (KF) and computed the $SpO_{2}$ mean absolute error (MAE) from each channel individually and after integrating the two channels. The $SpO_{2}$ MAEs of each one of the two channels separately were greater (and statistically significant) than the $SpO_{2}$ MAE obtained from the two channels integrated with a KF. We observed that when two channels of PPG (red and infrared) signals were available, then combining $SpO_{2}$ levels obtained from these two channels exhibited a smoother and more reliable estimate of the blood oxygen saturation level as compared the $SpO_{2}$ levels computed from each channel separately. The reason is that if the data for the two channels are collected at sufficient physical distance from one another, the motion artifacts affecting the two channels are uncorrelated. The KF is then able to use past measurements and modeling of the dynamics to attenuate the effect of the motion artifacts.- 21 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 5, 46-51
Mitigation of Motion Artifacts in Pulse Oximetry through Redundant Sensors
Photoplethysmography (PPG) signals are used in pulse oximetry to calculate peripheral capillary oxygen saturation $(SpO_{2})$ levels. It is well known that the accuracy of the calculated $SpO_{2}$ is susceptible to motion noise. Using field data collected from human subjects during rest and while exhibiting medium to high-intensity physical exercises, we show how sensor redundancy can mitigate motion effects by employing two channels of red and infrared PPG signals. We demonstrate the advantage of redundancy using two $SpO_{2}$ calculation methods. These methods are widely used “Red over Infrared” (RoI) method and the Discrete Saturation Transform (DST) algorithm both, assisted by pre-filtering by a heart-rate tuned comb filter. The data were collected from individuals at rest and while exercising. $SpO_{2}$ levels are calculated for two channels, each using a red and an infrared PPG signal. We integrated the $SpO_{2}$ computed from the two channels with a Kalman filter (KF) and computed the $SpO_{2}$ mean absolute error (MAE) from each channel individually and after integrating the two channels. The $SpO_{2}$ MAEs of each one of the two channels separately were greater (and statistically significant) than the $SpO_{2}$ MAE obtained from the two channels integrated with a KF. We observed that when two channels of PPG (red and infrared) signals were available, then combining $SpO_{2}$ levels obtained from these two channels exhibited a smoother and more reliable estimate of the blood oxygen saturation level as compared the $SpO_{2}$ levels computed from each channel separately. The reason is that if the data for the two channels are collected at sufficient physical distance from one another, the motion artifacts affecting the two channels are uncorrelated. The KF is then able to use past measurements and modeling of the dynamics to attenuate the effect of the motion artifacts.- 8 September 2020
- Published by American Society for Engineering Education
Work in Progress - Integration of Voice Technology into the First-Year Engineering Curriculum
Voice technology is a growing field and is becoming more prominent in society. In a study, National Public Research found that 65% of voice-enabled smart speakers’ users would not want to go back to life without using them and an estimated 39 million people own a voice-enabled smart speaker (National Public Media, 2017). The Amazon Alexa devices are such cloud-based, continuously improving, digital assistants designed to respond to voice commands. They are able to answer many questions and the number of questions they can answer is continuously increasing. One of the newer innovative applications of the Amazon Alexa devices is starting its integration into higher education. However, the focus of integrating voice technology thus far has been through campus life and residence halls and not through classroom instruction for actual curriculum (Ask ASU, 2018 & Developer Amazon, 2018). This work-in-progress paper will summarize our efforts on embedding voice technology into our first-year fundamentals of engineering design course that reviews the basic concepts of engineering and introduces some tools used for the design and implementation of devices and systems. The goal is to enhance student learning through hands-on projects in first-year design courses and use this to not only further engage students with the course content, but also foster the skills necessary for effective communication on projects with multiple stakeholders. Students, with little background on the subject, are designing a working device (such as a portable fan, a remotely-controlled car, or a robotic arm) using Computer-Aided Design (CAD) software, making the parts with 3D printers, creating an Arduino code to control the action of their device, and finally writing a voice interface (given a skeleton code) to actuate the servo motors on the device using voice commands. For example, students use voice to turn a fan on or off, change its speed, and enable oscillation. Ours is a unique approach towards not only integrating new emerging technology into the classroom but also finding new ways to engage students and help them learn new skills. Upon completion of this pilot, we expect that students would have expanded their communication, collaboration, and listening skills, learned how to personalize Voice technology, and the researchers would have improved the course design as well as prepared for the study to be offered on a larger scale.
- 8 September 2020
- Published by American Society for Engineering Education
Work in Progress - Integration of Voice Technology into the First-Year Engineering Curriculum
Voice technology is a growing field and is becoming more prominent in society. In a study, National Public Research found that 65% of voice-enabled smart speakers’ users would not want to go back to life without using them and an estimated 39 million people own a voice-enabled smart speaker (National Public Media, 2017). The Amazon Alexa devices are such cloud-based, continuously improving, digital assistants designed to respond to voice commands. They are able to answer many questions and the number of questions they can answer is continuously increasing. One of the newer innovative applications of the Amazon Alexa devices is starting its integration into higher education. However, the focus of integrating voice technology thus far has been through campus life and residence halls and not through classroom instruction for actual curriculum (Ask ASU, 2018 & Developer Amazon, 2018). This work-in-progress paper will summarize our efforts on embedding voice technology into our first-year fundamentals of engineering design course that reviews the basic concepts of engineering and introduces some tools used for the design and implementation of devices and systems. The goal is to enhance student learning through hands-on projects in first-year design courses and use this to not only further engage students with the course content, but also foster the skills necessary for effective communication on projects with multiple stakeholders. Students, with little background on the subject, are designing a working device (such as a portable fan, a remotely-controlled car, or a robotic arm) using Computer-Aided Design (CAD) software, making the parts with 3D printers, creating an Arduino code to control the action of their device, and finally writing a voice interface (given a skeleton code) to actuate the servo motors on the device using voice commands. For example, students use voice to turn a fan on or off, change its speed, and enable oscillation. Ours is a unique approach towards not only integrating new emerging technology into the classroom but also finding new ways to engage students and help them learn new skills. Upon completion of this pilot, we expect that students would have expanded their communication, collaboration, and listening skills, learned how to personalize Voice technology, and the researchers would have improved the course design as well as prepared for the study to be offered on a larger scale.