Shubhrojit Misra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Shubhrojit Misra has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Dyah Titisari
Department of Medical Electronics Technology, Poltekkes Kemenkes Surabaya, Surabaya, Indonesia
2 shared publicationsFarid Amrinsani
Department of Medical Electronics Technology, Poltekkes Kemenkes Surabaya, Indonesia
2 shared publicationsHer Gumiwang Ariswati
Department of Medical Electronics Technology, Poltekkes Kemenkes Surabaya, Surabaya, Indonesia
2 shared publicationsTorib Hamzah
Department of Medical Electronics Technology, Poltekkes Kemenkes Surabaya
2 shared publicationsAdam Meredita Realdo
Politeknik Perkapalan Negeri Surabaya
1 shared publicationAndjar Pudji
Department of Medical Electronics Engineering Technology, Poltekkes Kemenkes Surabaya
1 shared publication
Latest Publications
- Open Access
- 29 August 2023
- Published by Poltekkes Kemenkes Surabaya in Indonesian Journal of electronics, electromedical engineering, and medical informatics
- Vol. 5 (3) , 135-143
Anc Bed For Preeclamsi Early Detection Using Web System
One of the causes of the high maternal mortality rate is dominated by three factors, one of which is preeclampsia. Preeclampsia is a condition in which the mother experiences hypertension and changes in BMI (Body Mass Index) at the 20th week of gestation. Preeclampsia indications in pregnant women are related to examinations, namely Antenatal care (ANC). Antenatal care is one of the prenatal checks with certain standards. Pregnant women need extra antenatal supervision from health workers. Preeclampsia detection carried out in health care facilities is currently considered to be still not optimal so that there are still many cases of preeclampsia that are not handled properly. One of the efforts that can be made to improve services for pregnant women is with a web-based ANC examination. The purpose of this study is to analyze NIBP and BMI data sent and received by IoT media so that they are useful for the diagnostic process. The contribution of this research is knowing the response of NIBP and BMI data sent and received via IoT media. The procedure for achieving this goal is with the MPX5050 sensor and Loadcell whose output will be processed and displayed on a web page. From this study it can be concluded that the sending of IoT-based NIBP and IMT data affects lost data or delays received. The findings from this study are expected to be developed in further research. So that it can be said that the use of the ESP32 module as the delivery of ANC BED inspection results resulted in no loss of data found in sending ANC inspection results with 100% data results being sent without any data loss and delay with an average of 2 seconds.
- 29 August 2023
- Published by Poltekkes Kemenkes Surabaya in Indonesian Journal of electronics, electromedical engineering, and medical informatics
- Vol. 5 (3) , 135-143
Open AccessAnc Bed For Preeclamsi Early Detection Using Web System
One of the causes of the high maternal mortality rate is dominated by three factors, one of which is preeclampsia. Preeclampsia is a condition in which the mother experiences hypertension and changes in BMI (Body Mass Index) at the 20th week of gestation. Preeclampsia indications in pregnant women are related to examinations, namely Antenatal care (ANC). Antenatal care is one of the prenatal checks with certain standards. Pregnant women need extra antenatal supervision from health workers. Preeclampsia detection carried out in health care facilities is currently considered to be still not optimal so that there are still many cases of preeclampsia that are not handled properly. One of the efforts that can be made to improve services for pregnant women is with a web-based ANC examination. The purpose of this study is to analyze NIBP and BMI data sent and received by IoT media so that they are useful for the diagnostic process. The contribution of this research is knowing the response of NIBP and BMI data sent and received via IoT media. The procedure for achieving this goal is with the MPX5050 sensor and Loadcell whose output will be processed and displayed on a web page. From this study it can be concluded that the sending of IoT-based NIBP and IMT data affects lost data or delays received. The findings from this study are expected to be developed in further research. So that it can be said that the use of the ESP32 module as the delivery of ANC BED inspection results resulted in no loss of data found in sending ANC inspection results with 100% data results being sent without any data loss and delay with an average of 2 seconds.
- Open Access
- 30 May 2023
- Published by Poltekkes Kemenkes Surabaya in Indonesian Journal of electronics, electromedical engineering, and medical informatics
- Vol. 5 (2) , 92-100
Waterbath Temperature Control System with Fuzzy Logic
Unstable temperature or being outside the control temperature of a sample will cause a change in the quality of the sample itself. The purpose of this study was to create a temperature control system on waterbath with fuzzy logic using 7 labels. Used the DS18B20 sensor as a temperature sensor, a processor in the form of an UNO arduino, a thermostat as part of safety control, and displayed on a 16x4 LCD. Temperature selection between 30°C-60C. Design research using pre-experimental methods with one type group of post-testing design research, by comparing modules with comparison tools in the form of digital thermometers. The results of the research in the manufacture of waterbath tools were conducted compared to the results of measurements in the room with a digital thermometer. Obtained the highest Error value of 0.91% at 35 °C and the lowest error of 0.049% at 60 °C. While the error value based on the setting temperature obtained the highest error value at the temperature setting of 30°C of 1.38% and the lowest error at the temperature setting of 60 °C of 0.05%. The average time required to reach the shortest setting temperature in the temperature range is 27°C-30°C for 193 seconds, and the longest time in the temperature range is 27°C-60°C for 2257 seconds. the results showed that the fuzzy method is better compared to conventional methods. The results of this study can be implemented for waterbath temperature control system to get more stable results in maintaining setting temperature.
- 30 May 2023
- Published by Poltekkes Kemenkes Surabaya in Indonesian Journal of electronics, electromedical engineering, and medical informatics
- Vol. 5 (2) , 92-100
Open AccessWaterbath Temperature Control System with Fuzzy Logic
Unstable temperature or being outside the control temperature of a sample will cause a change in the quality of the sample itself. The purpose of this study was to create a temperature control system on waterbath with fuzzy logic using 7 labels. Used the DS18B20 sensor as a temperature sensor, a processor in the form of an UNO arduino, a thermostat as part of safety control, and displayed on a 16x4 LCD. Temperature selection between 30°C-60C. Design research using pre-experimental methods with one type group of post-testing design research, by comparing modules with comparison tools in the form of digital thermometers. The results of the research in the manufacture of waterbath tools were conducted compared to the results of measurements in the room with a digital thermometer. Obtained the highest Error value of 0.91% at 35 °C and the lowest error of 0.049% at 60 °C. While the error value based on the setting temperature obtained the highest error value at the temperature setting of 30°C of 1.38% and the lowest error at the temperature setting of 60 °C of 0.05%. The average time required to reach the shortest setting temperature in the temperature range is 27°C-30°C for 193 seconds, and the longest time in the temperature range is 27°C-60°C for 2257 seconds. the results showed that the fuzzy method is better compared to conventional methods. The results of this study can be implemented for waterbath temperature control system to get more stable results in maintaining setting temperature.
- Open Access
- 8 December 2022
- Published by Poltekkes Kemenkes Surabaya in Jurnal Teknokes
- Vol. 15 (4) , 223–229
High Flow Oxygen Analyzer Design on High Flow Nasal Cannula (HFNC) for Monitoring Oxygen therapy in Adults
High Flow Nasal Canulla (HFNC) is a technique that provides a high flow of heated and humidified gas. HFNC is simpler to use and implement than noninvasive ventilation (NIV) and appears to be a good alternative treatment for hypoxemic acute respiratory failure (ARF). This study aims to help facilitate medical personnel or equipment operators in monitoring the flow that enters the patient's body so that oxygen therapy can be given according to the right dose. This study uses an Arduino microcontroller to process the output flow from the Sensirion SFM-3000 flow sensor, then the processed flow value will be displayed on the TFT LCD. The independent variable in this study is the flow setting value, while the dependent variable is the SFM-3000 flow sensor. The largest error flow value is in the setting at 30 LPM with an error value of 2.70%. The flow value is set using a flowmeter, while the comparison tool used is a flow analyzer (Citrex H3). In the testing phase, the measurement value is 10 LPM to 60 LPM with a time of 5 minutes at each point. Based on the measurements that have been made, the largest error value is obtained at the value of 30 LPM, which is 2.70% and the smallest error value is at the value of 60 LPM, which is 0.74%. Data retrieval using a compressor and central oxygen is very influential on the results of the flow and oxygen concentration. The results obtained are more stable than without the use of a compressor and central oxygen.The conclusion from these results is that the calibrator module has a relative error (error value) that is still within the allowable tolerance limit, which is ±5%. And also the design of this tool is portable and low cost and is made to be used in hospital agencies as a support for maintenance on HFNC equipment
- 8 December 2022
- Published by Poltekkes Kemenkes Surabaya in Jurnal Teknokes
- Vol. 15 (4) , 223–229
Open AccessHigh Flow Oxygen Analyzer Design on High Flow Nasal Cannula (HFNC) for Monitoring Oxygen therapy in Adults
High Flow Nasal Canulla (HFNC) is a technique that provides a high flow of heated and humidified gas. HFNC is simpler to use and implement than noninvasive ventilation (NIV) and appears to be a good alternative treatment for hypoxemic acute respiratory failure (ARF). This study aims to help facilitate medical personnel or equipment operators in monitoring the flow that enters the patient's body so that oxygen therapy can be given according to the right dose. This study uses an Arduino microcontroller to process the output flow from the Sensirion SFM-3000 flow sensor, then the processed flow value will be displayed on the TFT LCD. The independent variable in this study is the flow setting value, while the dependent variable is the SFM-3000 flow sensor. The largest error flow value is in the setting at 30 LPM with an error value of 2.70%. The flow value is set using a flowmeter, while the comparison tool used is a flow analyzer (Citrex H3). In the testing phase, the measurement value is 10 LPM to 60 LPM with a time of 5 minutes at each point. Based on the measurements that have been made, the largest error value is obtained at the value of 30 LPM, which is 2.70% and the smallest error value is at the value of 60 LPM, which is 0.74%. Data retrieval using a compressor and central oxygen is very influential on the results of the flow and oxygen concentration. The results obtained are more stable than without the use of a compressor and central oxygen.The conclusion from these results is that the calibrator module has a relative error (error value) that is still within the allowable tolerance limit, which is ±5%. And also the design of this tool is portable and low cost and is made to be used in hospital agencies as a support for maintenance on HFNC equipment
- Open Access
- 24 November 2022
- Published by Poltekkes Kemenkes Surabaya in Indonesian Journal of electronics, electromedical engineering, and medical informatics
- Vol. 4 (4) , 160-167
Analysis of The Accuracy of Temperature Sensors at The Calibrator Incubator Laboratory are equipped with data storage base on Internet of Thing
A laboratory incubator is a tool used to incubate or incubate a breed. Incubators provide optimum temperature conditions for microorganisms to grow. The incubator has a temperature regulator so that the temperature can be adjusted according to the breed to be incarnated. Incubators utilize hot-dry like ovens. The purpose of this study is to conduct testing and analyze the accuracy of thermocouple sensors with incubator media in laboratory incubator calibrator tools. The contribution of the research is to know the level of accuracy of the sustainable sensor for sensing the temperature in the lab incubator. The main Design consists of 8 MAX 6675 Standards, 8 Thermocouple type K, Arduino Mega, and SD Card Standards. The temperature not in the incubator device is measured by a Type K thermocouple sensor. Thermocouple sensor numbers 8 channels that measure the temperature at each incubator camber point. The temperature will be stored on the SD card to analyze the data and the data can be processed into the form of a graphic. Benchmarking is done using a data logger temperature tool. This is done to make the Design results are under the standards of the Standard. After comparing with the Standard get the largest error value is 3.98%, at channel T6 temperature 35 °C with ordinary incubator media and the smallest error in ordinary incubator media point T6 temperature 37 ° C which is 0.06 % and in fan incubator temperature 35 C has the largest error which is 2.98 % and the smallest error 0.86%. The conclusion of this study is that the design can work well in measuring the temperature of the incubator, as well as the system for storing readings using the SD card Design and sending data using the internet network can work well.
- 24 November 2022
- Published by Poltekkes Kemenkes Surabaya in Indonesian Journal of electronics, electromedical engineering, and medical informatics
- Vol. 4 (4) , 160-167
Open AccessAnalysis of The Accuracy of Temperature Sensors at The Calibrator Incubator Laboratory are equipped with data storage base on Internet of Thing
A laboratory incubator is a tool used to incubate or incubate a breed. Incubators provide optimum temperature conditions for microorganisms to grow. The incubator has a temperature regulator so that the temperature can be adjusted according to the breed to be incarnated. Incubators utilize hot-dry like ovens. The purpose of this study is to conduct testing and analyze the accuracy of thermocouple sensors with incubator media in laboratory incubator calibrator tools. The contribution of the research is to know the level of accuracy of the sustainable sensor for sensing the temperature in the lab incubator. The main Design consists of 8 MAX 6675 Standards, 8 Thermocouple type K, Arduino Mega, and SD Card Standards. The temperature not in the incubator device is measured by a Type K thermocouple sensor. Thermocouple sensor numbers 8 channels that measure the temperature at each incubator camber point. The temperature will be stored on the SD card to analyze the data and the data can be processed into the form of a graphic. Benchmarking is done using a data logger temperature tool. This is done to make the Design results are under the standards of the Standard. After comparing with the Standard get the largest error value is 3.98%, at channel T6 temperature 35 °C with ordinary incubator media and the smallest error in ordinary incubator media point T6 temperature 37 ° C which is 0.06 % and in fan incubator temperature 35 C has the largest error which is 2.98 % and the smallest error 0.86%. The conclusion of this study is that the design can work well in measuring the temperature of the incubator, as well as the system for storing readings using the SD card Design and sending data using the internet network can work well.
- Open Access
- 18 September 2022
- Published by Elsevier in Measurement: Sensors
- Vol. 24
Deep learning approach to solve image retrieval issues associated with IOT sensors
- 18 September 2022
- Published by Elsevier in Measurement: Sensors
- Vol. 24
Open AccessDeep learning approach to solve image retrieval issues associated with IOT sensors
- Open Access
- 28 July 2022
- Published by Poltekkes Kemenkes Surabaya in Journal of Electronics, Electromedical Engineering, and Medical Informatics
- Vol. 4 (3) , 135-143
Sensor Accuracy Analysis on Incubator Analyzer to Measure Noise and Airflow Parameters
Infant incubators are equipment to maintain a stable body temperature for premature babies. Premature babies need room conditioning that is close to conditions in the womb. Room conditioning is carried out in a baby incubator by providing a stable temperature, relative humidity, and measured air flow. This parameter must be controlled so as not to exceed the threshold that will harm the baby. Periodic calibration should be applied to the infant incubator to monitor its function. To ensure the availability of baby incubators according to service standards, it is necessary to conduct test (calibrate) using an incubator analyzer. The purpose of this study is to conduct further research on the incubator analyzer that focuses on discussing the accuracy of noise and airflow sensors with the gold standard. In this study, an experiment was carried out for the sensitivity level of several sensors that had been treated by giving treatment to sensors to choose sensors with good sensitivity to be assembled into one in the incubator analyzer module. The noise sensors (KY-037 and Analog Sound Sensor V2.2) were further compared with the values on the sound level meter and the airflow sensor (D6F-V03A1) was compared with the anemometer. Sensors whose values are close to the comparison values were selected to be integrated into the incubator analyzer module. The incubator analyzer module used Arduino Mega2560 as a data processor and was equipped with an SD Card for the data storage. The built incubator analyzer module was also compared to the Fluke INCU II gold standard for data analysis. The results showed that the Analog Sound Sensor V2.2 had the highest error value (-4.6%) at 32°C and the D6F-V03A1 had the ability to measure sensitivity, where the results were more accurate than INCU II. Based on the error value of the noise sensor, the V2.2 sensor can be applied to measure noise in the baby incubator and the D6F-V03A1 airflow sensor produced an accuracy of up to 3 digits behind the comma which is more accurate than the standard module. The results of the INCU analyzer from this study can be used to calibrate the baby incubator, so that the certainty of the feasibility of the baby incubator is guaranteed. This research can be used as a reference for other researchers who will develop research on incubator analyzers in the future.
- 28 July 2022
- Published by Poltekkes Kemenkes Surabaya in Journal of Electronics, Electromedical Engineering, and Medical Informatics
- Vol. 4 (3) , 135-143
Open AccessSensor Accuracy Analysis on Incubator Analyzer to Measure Noise and Airflow Parameters
Infant incubators are equipment to maintain a stable body temperature for premature babies. Premature babies need room conditioning that is close to conditions in the womb. Room conditioning is carried out in a baby incubator by providing a stable temperature, relative humidity, and measured air flow. This parameter must be controlled so as not to exceed the threshold that will harm the baby. Periodic calibration should be applied to the infant incubator to monitor its function. To ensure the availability of baby incubators according to service standards, it is necessary to conduct test (calibrate) using an incubator analyzer. The purpose of this study is to conduct further research on the incubator analyzer that focuses on discussing the accuracy of noise and airflow sensors with the gold standard. In this study, an experiment was carried out for the sensitivity level of several sensors that had been treated by giving treatment to sensors to choose sensors with good sensitivity to be assembled into one in the incubator analyzer module. The noise sensors (KY-037 and Analog Sound Sensor V2.2) were further compared with the values on the sound level meter and the airflow sensor (D6F-V03A1) was compared with the anemometer. Sensors whose values are close to the comparison values were selected to be integrated into the incubator analyzer module. The incubator analyzer module used Arduino Mega2560 as a data processor and was equipped with an SD Card for the data storage. The built incubator analyzer module was also compared to the Fluke INCU II gold standard for data analysis. The results showed that the Analog Sound Sensor V2.2 had the highest error value (-4.6%) at 32°C and the D6F-V03A1 had the ability to measure sensitivity, where the results were more accurate than INCU II. Based on the error value of the noise sensor, the V2.2 sensor can be applied to measure noise in the baby incubator and the D6F-V03A1 airflow sensor produced an accuracy of up to 3 digits behind the comma which is more accurate than the standard module. The results of the INCU analyzer from this study can be used to calibrate the baby incubator, so that the certainty of the feasibility of the baby incubator is guaranteed. This research can be used as a reference for other researchers who will develop research on incubator analyzers in the future.
- Open Access
- 7 June 2022
- Published by Poltekkes Kemenkes Surabaya in Jurnal Teknokes
- Vol. 15 (2) , 117-123
Infant Warmer with Digital Scales for Auto Adjustment PID Control Parameters
Babies need temperatures that match the temperature of the mother's womb, which is between 35°C – 37°C. The latest research on infant warmer device used fuzzy method as a system for controlling temperature in infant warmers. The problem raised in the previous research is that the temperature was not evenly distributed throughout the bed at each predetermined temperature setting. When it reached the setting temperature, the warmer continued to turn on so that the bed got hotter. Therefore, the purpose of the current research is to make an infant warmer device equipped with digital scales with a temperature setting of 350C- 370C using PID control to stabilize the temperature and ensure that the heat is evenly distributed on the bed. In addition, skin temperature is also added, allowing the nurses know at which level of patient's body temperature is when observations should be made. The infant warmer in this module used an arduino microcontroller which is displayed in 7 segments, the skin sensor used is the DS18B20 temperature sensor to read the skin temperature, while the infant warmer temperature sensor used is LM35 as a PID control system. The results of the current research in making the device module were compared with the measurement results of the comparator. It was revealed that current research has obtained smallest error of 0% in temperature setting of 350C. For the comparison with the incu analyzer, the smallest error was obtained at the temperature setting of 370C with an error value of 0% on the T5 measurement. Meanwhile, the difference in skin temperature against the thermometer is 0.10C. The results showed that the temperature distributed on the module had different error values. Hence, this research can be implemented on the PID control of infant warmer system to improve the performance of infant temperature stability.
- 7 June 2022
- Published by Poltekkes Kemenkes Surabaya in Jurnal Teknokes
- Vol. 15 (2) , 117-123
Open AccessInfant Warmer with Digital Scales for Auto Adjustment PID Control Parameters
Babies need temperatures that match the temperature of the mother's womb, which is between 35°C – 37°C. The latest research on infant warmer device used fuzzy method as a system for controlling temperature in infant warmers. The problem raised in the previous research is that the temperature was not evenly distributed throughout the bed at each predetermined temperature setting. When it reached the setting temperature, the warmer continued to turn on so that the bed got hotter. Therefore, the purpose of the current research is to make an infant warmer device equipped with digital scales with a temperature setting of 350C- 370C using PID control to stabilize the temperature and ensure that the heat is evenly distributed on the bed. In addition, skin temperature is also added, allowing the nurses know at which level of patient's body temperature is when observations should be made. The infant warmer in this module used an arduino microcontroller which is displayed in 7 segments, the skin sensor used is the DS18B20 temperature sensor to read the skin temperature, while the infant warmer temperature sensor used is LM35 as a PID control system. The results of the current research in making the device module were compared with the measurement results of the comparator. It was revealed that current research has obtained smallest error of 0% in temperature setting of 350C. For the comparison with the incu analyzer, the smallest error was obtained at the temperature setting of 370C with an error value of 0% on the T5 measurement. Meanwhile, the difference in skin temperature against the thermometer is 0.10C. The results showed that the temperature distributed on the module had different error values. Hence, this research can be implemented on the PID control of infant warmer system to improve the performance of infant temperature stability.
- Open Access
- 28 May 2022
- Published by Poltekkes Kemenkes Surabaya in Indonesian Journal of electronics, electromedical engineering, and medical informatics
- Vol. 4 (2) , 107-113
Analysis of Changes in Flow Setting Against Rise Time Using Gas Board 7500E Sensor on Bubble CPAP
Respiratory distress in neonates is one of the biggest problems encountered on a daily basis. Respiratory distress looks like rapid breathing in a newborn. CPAP Bubble is the right treatment in this case. Rise time is the time for airway pressure to reach the maximum standard value. A fast time value can make it possible to bring the breath pressure to a standard level. This study aims to analyze changes in setting flow to rise time using a gasboard sensor 7500E on a CPAP bubble device. The main advantage of this proposed method is that the results are displayed in the form of graphics, portable and there is data storage. This design uses a Gasboard 7500E sensor as a detector of oxygen concentration, a TFT LCD as a graphic display and an SD Card as data storage. The data collection is in the form of the average rise time of oxygen concentration followed by changes in its rate. Data were taken five times with three different CPAPs. The results showed that the increase in the rate affect the rise time of the CPAP oxygen concentration.
- 28 May 2022
- Published by Poltekkes Kemenkes Surabaya in Indonesian Journal of electronics, electromedical engineering, and medical informatics
- Vol. 4 (2) , 107-113
Open AccessAnalysis of Changes in Flow Setting Against Rise Time Using Gas Board 7500E Sensor on Bubble CPAP
Respiratory distress in neonates is one of the biggest problems encountered on a daily basis. Respiratory distress looks like rapid breathing in a newborn. CPAP Bubble is the right treatment in this case. Rise time is the time for airway pressure to reach the maximum standard value. A fast time value can make it possible to bring the breath pressure to a standard level. This study aims to analyze changes in setting flow to rise time using a gasboard sensor 7500E on a CPAP bubble device. The main advantage of this proposed method is that the results are displayed in the form of graphics, portable and there is data storage. This design uses a Gasboard 7500E sensor as a detector of oxygen concentration, a TFT LCD as a graphic display and an SD Card as data storage. The data collection is in the form of the average rise time of oxygen concentration followed by changes in its rate. Data were taken five times with three different CPAPs. The results showed that the increase in the rate affect the rise time of the CPAP oxygen concentration.
- Open Access
- 6 November 2021
- Published by Poltekkes Kemenkes Surabaya in Indonesian Journal of electronics, electromedical engineering, and medical informatics
- Vol. 3 (4) , 179-184
Design and Development of Electricity Use Management System of Surabaya State Shipping Polytechnic Based on Decision Tree Algorithm
Electrical energy has become a primary need in society, including in education. This is related to the number of electrical equipment used to support teaching and learning activities. However, this is not directly proportional to the students' awareness of the importance of saving energy. From this, the authors create a management system for electric power, which aims to save electricity consumption by limiting the use of electrical loads. In this system, the method used is a decision tree; the goal is to limit and set priorities for electrical loads. When three classes are ON simultaneously, there will be a reduction in the electrical load. There is a website for monitoring and changing the automatic or manual mode in this system. The manual mode is used to control the electrical load according to the status entered on the website. While the automatic mode regulates the use of electrical loads by controlling the ON or OFF conditions using a schedule that has been made, the website also monitors current, voltage, power, energy, and usage costs. The system has been tested with automatic and manual modes for monitoring data on the website. It has data updates every 10 minutes. The system has also been tested by scheduling using a decision tree and compared with scheduling without using a decision tree. From the test results for a day, it can be concluded that the system created is able to save electricity consumption. This is reinforced by a decrease in energy use of 1,17 kWh and a cost of Rp. 1.116.
- 6 November 2021
- Published by Poltekkes Kemenkes Surabaya in Indonesian Journal of electronics, electromedical engineering, and medical informatics
- Vol. 3 (4) , 179-184
Open AccessDesign and Development of Electricity Use Management System of Surabaya State Shipping Polytechnic Based on Decision Tree Algorithm
Electrical energy has become a primary need in society, including in education. This is related to the number of electrical equipment used to support teaching and learning activities. However, this is not directly proportional to the students' awareness of the importance of saving energy. From this, the authors create a management system for electric power, which aims to save electricity consumption by limiting the use of electrical loads. In this system, the method used is a decision tree; the goal is to limit and set priorities for electrical loads. When three classes are ON simultaneously, there will be a reduction in the electrical load. There is a website for monitoring and changing the automatic or manual mode in this system. The manual mode is used to control the electrical load according to the status entered on the website. While the automatic mode regulates the use of electrical loads by controlling the ON or OFF conditions using a schedule that has been made, the website also monitors current, voltage, power, energy, and usage costs. The system has been tested with automatic and manual modes for monitoring data on the website. It has data updates every 10 minutes. The system has also been tested by scheduling using a decision tree and compared with scheduling without using a decision tree. From the test results for a day, it can be concluded that the system created is able to save electricity consumption. This is reinforced by a decrease in energy use of 1,17 kWh and a cost of Rp. 1.116.
- Open Access
- 28 May 2021
- Published by Poltekkes Kemenkes Surabaya in Indonesian Journal of electronics, electromedical engineering, and medical informatics
- Vol. 3 (2) , 59-64
Design a Low-Cost Digital Pressure Meter Equipped with Temperature and Humidity Parameters
Calibration is a technical activity which consists of determining one or more properties and characteristics of a product, process or service according to a predetermined special procedure. The purpose of calibration is to ensure measurement results comply with national and international standards. The purpose of this study is to design two mode digital pressure meter (DPM) device equipped with a thermo-hygrometer and pressure in which the design is completed with a selection mode to determine the positive and negative pressure (vacuum) using MPX 5050GP sensor as a positive pressure sensor. In this design DHT 22 sensors is used to measure the humidity and temperature. To test the leak test this device is also equipped with timer. This design uses a 2.4 inch Nextion TFT LCD screen to display data. Data analysis was performed by comparing modul with standard tools. In the measurement process, Mercury tensimeter was carried out 6 times the data and the smallest results were 0 mmHg on the module and 0 mmHg on the standard tool and the largest was 298.0 mmHg on the module and 300 mmHg on the standard tool. Data were collected in a room with a temperature of 31̊C and humidity of 87%. Finally, this design is applicable for daily used for electromedical engineer to calibrate the sphygmomanometer in the hospitals
- 28 May 2021
- Published by Poltekkes Kemenkes Surabaya in Indonesian Journal of electronics, electromedical engineering, and medical informatics
- Vol. 3 (2) , 59-64
Open AccessDesign a Low-Cost Digital Pressure Meter Equipped with Temperature and Humidity Parameters
Calibration is a technical activity which consists of determining one or more properties and characteristics of a product, process or service according to a predetermined special procedure. The purpose of calibration is to ensure measurement results comply with national and international standards. The purpose of this study is to design two mode digital pressure meter (DPM) device equipped with a thermo-hygrometer and pressure in which the design is completed with a selection mode to determine the positive and negative pressure (vacuum) using MPX 5050GP sensor as a positive pressure sensor. In this design DHT 22 sensors is used to measure the humidity and temperature. To test the leak test this device is also equipped with timer. This design uses a 2.4 inch Nextion TFT LCD screen to display data. Data analysis was performed by comparing modul with standard tools. In the measurement process, Mercury tensimeter was carried out 6 times the data and the smallest results were 0 mmHg on the module and 0 mmHg on the standard tool and the largest was 298.0 mmHg on the module and 300 mmHg on the standard tool. Data were collected in a room with a temperature of 31̊C and humidity of 87%. Finally, this design is applicable for daily used for electromedical engineer to calibrate the sphygmomanometer in the hospitals