    Creation and Preclinical Testing of a Spirometer with Extended Functionality

    by V. S. Shabaev, V. A. Onoshko, A. S. Galushko, V. A. Mazurok, I. V. Orazmagomedova, L. G. Vasilyeva, D. A. Aleksandrova

    RELEVANCE. We present the results of preclinical testing of an upgraded portable AR­1 gas flow analyzer produced by JSC Krasnogvardeets (Saint Petersburg) in order to create import-substituting technologies and develop practical and scientific spheres of healthcare.THE AIM OF THE STUDY. was to substantiate the possibility of clinical use of the upgraded device, originally intended for testing ventilators and inhalation anesthesia devices, as a monitor of the external respiration apparatus function.MATERIAL AND METHODS. The preclinical study of the upgraded gas flow analyzer was conducted at the V.A. Almazov National Medical Research Center in comparison with devices for conventional (Bellavista 950, Berner Ross Medical, Russia) and high-frequency (IPV-2C, Intrapulmonary Percussive Ventilation, Percussionaire Corporation, USA) mechanical ventilation in volume- and pressure-controlled modes using an artificial lung. The following reflected spirometry parameters were compared: tidal and minute volume under inhalation and exhalation, respiratory rate, maximum and minimum flows, peak and positive end expiratory pressure, fraction of inspired oxygen.RESULTS. A high accuracy of parameter matching shown by the gas flow analyzer and ventilators was demonstrated.CONCLUSION. The upgraded model of the gas flow analyzer can be used clinically as a portable spirometer at the prehospital and hospital stages.

  • Open Access

    Sonography indicators of diaphragm and their correlation with spirometry data in healthy individuals: a prospective study

    by V. S. Shabaev, I. V. Orazmagomedova, Вадим Альбертович Мазурок, A. V. Berezina, L. G. Vasilyeva, D. A. Aleksandrova

    OBJECTIVE: Revealing the correlation between sonography indicators of diaphragm performance and spirometry data of healthy persons. MATERIALS AND METHODS: The study was conducted at the Almazov National Medical Research Centre. The structural (thickness) and functional (thickening fraction and excursion of diaphragm) state of diaphragm of 50 healthy individuals (female — 30) was assessed with an ultrasound machine, and the spirometry characteristics of the external breathing apparatus were assessed with a ventilator. Afterwards the statistical and correlation analysis was conducted. RESULTS: It was possible to assess the thickness of diaphragm on both sides and the diaphragm excursion on the right in all subjects, the diaphragm excursion on the left — only in 20 % of subjects. Spirometry has been performed in all subjects. The obtained data are consistent with the literature. In particular, sonography and spirometry indicators of the healthy individuals are within reference values. Inspiratory muscles strength has also proved to be consistent with the literature data. Correlation analysis has revealed no statistically significant relationship between the examined sonography and spirometry parameters. In addition, no relation between age and sonography indicators of diaphragm has been found. There are weak statistically significant relations revealed between the structural and functional state of diaphragm and such anthropometric characteristics of the subjects as body mass and body mass index. CONCLUSIONS: Sonography indicators of diaphragm performance do not correlate or correlate poorly with spirometry data. There is no reason to use sonography of diaphragm in healthy individuals since it does not practically provide any additional information about the state of external respiratory apparatus.


  • Diaphragmatic dysfunction in patients with chronic heart failure

    by V.S. Shabaev, I.V. Orazmagomedova, V.A. Mazurok, A.V. Berezina, A.E. Bautin, L.G. Vasilyeva, D.A. Aleksandrova

    Objective. To detect diaphragmatic dysfunction in patients with chronic heart failure (CHF) via assessment of structural and functional state of external respiration. Material and methods. The study was conducted at the Almazov National Medical Research Center and included 58 subjects. There were 40 patients with CHF and 18 ones without CHF (control group). Inclusion criterion for the main group was CHF NYHA class II—IV. Exclusion criteria for both groups were pulmonary diseases, morbid obesity, abdominal diseases and anemia. We performed ultrasonic assessment of structural (thickness) and functional (thickening fraction and excursion) state of diaphragm under calm and deep inhalation/exhalation. External respiration was assessed using spirometry functions of a ventilator. Results. Patients with CHF had a thicker diaphragm on both sides and smaller volume of deep inhalation. Diaphragm thickening index was significantly less under deep inhalation on the right. Patients with CHF had a larger excursion of the right and left domes of the diaphragm under calm breathing, whereas no significant differences were found under deep breathing. We found a moderate positive linear correlation between CHF and diaphragm thickness on both sides under calm inhalation. Conclusion. Structural and functional diaphragmatic dysfunction makes a contribution to respiratory failure in patients with CHF.


  • sonography indicators of diaphragm in healthy individuals

    by V.S. Shabaev, I.V. Orazmagomedova, V.A. Mazurok, A.V. Berezina, L.G. Vasilyeva, D.A. Aleksandrova

    ЦЕЛЬ ИССЛЕДОВАНИЯ Получить сонографические показатели функционирования диафрагмы у здоровых в положении, приближенном к условиям пребывания на реанимационной койке. МАТЕРИАЛ И МЕТОДЫ Исследование проведено на базе ФГБУ «НМИЦ им. В.А. Алмазова» Минздрава России. Оценивали структурное функциональное состояние диафрагмы у 50 добровольцев (женщин — 30). Критерий невключения — наличие любых заболеваний и состояний, способных изменять работу диафрагмы. С помощью ультразвуковой диагностической системы CX50 (Philips Ultrasound, Inc., США) оценивали структурное (толщину) и функциональное (индекс утолщения и экскурсию диафрагмы) состояние диафрагмы во время спокойного и глубокого вдоха/выдоха. РЕЗУЛЬТАТЫ Визуализация экскурсии диафрагмы справа и толщина диафрагмы с обеих сторон оценена у 100% испытуемых, визуализация экскурсии слева — у 20% (n=10) испытуемых. Абсолютные величины толщины и экскурсии диафрагмы сопоставимы с данными литературы. Показатели ультразвукового исследования правой и левой гемисфер не имеют статистически значимых различий. Выявлены половые различия толщины диафрагмы: на высоте глубокого вдоха справа у мужчин 4,8 (4,2; 5,4) мм, у женщин 4,2 (3,5; 4,9) мм (p=0,02); при глубоком выдохе справа у мужчин 1,3 (1,2; 1,4) мм, у женщин 1,1 (0,9; 1,3) мм (p=0,01); на высоте спокойного вдоха слева у мужчин 2,0 (1,7; 2,2) мм, у женщин 1,7 (1,4; 1,8) мм (p=0,006); при спокойном выдохе слева у мужчин 1,5 (1,4; 1,7) мм, у женщин 1,3 (1,2; 1,5) мм (p=0,02); при глубоком выдохе слева у мужчин 1,2 (1,0; 1,4) мм, у женщин 1,1 (0,9; 1,1) мм (p=0,02), а также максимальной амплитуды экскурсии: при глубоком дыхании справа у мужчин 7,4 (6,3; 8,2) см, у женщин 6,6 (5,7; 7,5) см (p=0,04). ЗАКЛЮЧЕНИЕ Ультразвуковое исследование диафрагмы — удобный и воспроизводимый метод ее визуализации. Не выявлена статистически значимая структурная и функциональная асимметрия куполов диафрагмы. Имеются значимые половые различия.