Jiayi Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jiayi Hu has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Peng Dong
4 shared publications- Jinrui Cao
Department of Mechanics and Aerospace Engineering, Southern University of Science and Technology
3 shared publications Yuanlong Li
3 shared publicationsChen Lin
2 shared publicationsGui Li
2 shared publications- Hongyan Yuan
Department of Mechanics and Aerospace Engineering, Southern University of Science and Technology, Shenzhen, China
2 shared publications
Latest Publications
- Open Access
- 26 October 2026
- Published by Elsevier in Theoretical and Applied Mechanics Letters
Architecting resilience: Mechanical and multi-physics metamaterials for next-generation structural engineering
- 26 October 2026
- Published by Elsevier in Theoretical and Applied Mechanics Letters
Open AccessArchitecting resilience: Mechanical and multi-physics metamaterials for next-generation structural engineering
- 18 October 2026
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 331
Bi-material hexagonal multistable metamaterials with tunable bandgap and wave propagation
- 18 October 2026
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 331
Bi-material hexagonal multistable metamaterials with tunable bandgap and wave propagation
- 15 April 2025
- Published by Elsevier in Construction and Building Materials
- Vol. 476
Cementitious metamaterials for low-frequency vibration suppression: Inverse design and performance analysis
- 15 April 2025
- Published by Elsevier in Construction and Building Materials
- Vol. 476
Cementitious metamaterials for low-frequency vibration suppression: Inverse design and performance analysis
- Open Access
- 14 July 2024
- Published by Elsevier in Materials & Design
- Vol. 244
Topology-optimized lattice enhanced cementitious composites
- 14 July 2024
- Published by Elsevier in Materials & Design
- Vol. 244
Open AccessTopology-optimized lattice enhanced cementitious composites
- 11 June 2024
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 141 (34)
Large strain mechanical behaviors of optically clear adhesives for flexible electronic devices under different temperature, humidity, and strain rates
Optically clear adhesives (OCAs), a type of polymer pressure‐sensitive adhesive, are valued for their transparency, strong bonding, thermal stability, and reliability in flexible electronics. Accurately determining the mechanical properties of OCAs is importance for effectively assessing the structural integrity of foldable screens in finite element simulations. However, previous studies have primarily focused on small strain and conventional environmental conditions. To address this gap, the present study investigates the mechanical behaviors of OCAs under extreme conditions, including large strain (up to 1000%), high/low temperatures (−40, −20, 0, 25, 65, and 80°C), and high humidity (95% relative humidity). Specifically, the tensile, simple shear, and creep properties of OCAs have been assessed in an attempt to explore their visco‐hyperelastic behavior. The experimental findings indicate that OCA exhibits noticeable temperature sensitivity and viscoelasticity, along with volume‐incompressible properties. Notably, when the temperature is varied from −40 to 25°C and from 25 to 80°C, the modulus of OCA experiences an average reduction of 84% and 41% respectively. Moreover, it has been observed that humidity has a negligible effect on the material's modulus. The Yeoh model and Prony series are employed for fitting purposes. The proposed fitting parameters are subsequently validated through numerical simulations of three‐point bending case studies. Remarkably, the simulation results closely matched with the experimental data, with errors remaining below 10%.
- 11 June 2024
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 141 (34)
Large strain mechanical behaviors of optically clear adhesives for flexible electronic devices under different temperature, humidity, and strain rates
Optically clear adhesives (OCAs), a type of polymer pressure‐sensitive adhesive, are valued for their transparency, strong bonding, thermal stability, and reliability in flexible electronics. Accurately determining the mechanical properties of OCAs is importance for effectively assessing the structural integrity of foldable screens in finite element simulations. However, previous studies have primarily focused on small strain and conventional environmental conditions. To address this gap, the present study investigates the mechanical behaviors of OCAs under extreme conditions, including large strain (up to 1000%), high/low temperatures (−40, −20, 0, 25, 65, and 80°C), and high humidity (95% relative humidity). Specifically, the tensile, simple shear, and creep properties of OCAs have been assessed in an attempt to explore their visco‐hyperelastic behavior. The experimental findings indicate that OCA exhibits noticeable temperature sensitivity and viscoelasticity, along with volume‐incompressible properties. Notably, when the temperature is varied from −40 to 25°C and from 25 to 80°C, the modulus of OCA experiences an average reduction of 84% and 41% respectively. Moreover, it has been observed that humidity has a negligible effect on the material's modulus. The Yeoh model and Prony series are employed for fitting purposes. The proposed fitting parameters are subsequently validated through numerical simulations of three‐point bending case studies. Remarkably, the simulation results closely matched with the experimental data, with errors remaining below 10%.
- Open Access
- 9 December 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (49) , eabn7097
A myocardial infarct border-zone-on-a-chip demonstrates distinct regulation of cardiac tissue function by an oxygen gradient
After a myocardial infarction, the boundary between the injured, hypoxic tissue and the adjacent viable, normoxic tissue, known as the border zone, is characterized by an oxygen gradient. Yet, the impact of an oxygen gradient on cardiac tissue function is poorly understood, largely due to limitations of existing experimental models. Here, we engineered a microphysiological system to controllably expose engineered cardiac tissue to an oxygen gradient that mimics the border zone and measured the effects of the gradient on electromechanical function and the transcriptome. The gradient delayed calcium release, reuptake, and propagation; decreased diastolic and peak systolic stress; and increased expression of inflammatory cascades that are hallmarks of myocardial infarction. These changes were distinct from those observed in tissues exposed to uniform normoxia or hypoxia, demonstrating distinct regulation of cardiac tissue phenotypes by an oxygen gradient. Our border-zone-on-a-chip model advances functional and mechanistic insight into oxygen-dependent cardiac tissue pathophysiology.
- 9 December 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (49) , eabn7097
Open AccessA myocardial infarct border-zone-on-a-chip demonstrates distinct regulation of cardiac tissue function by an oxygen gradient
After a myocardial infarction, the boundary between the injured, hypoxic tissue and the adjacent viable, normoxic tissue, known as the border zone, is characterized by an oxygen gradient. Yet, the impact of an oxygen gradient on cardiac tissue function is poorly understood, largely due to limitations of existing experimental models. Here, we engineered a microphysiological system to controllably expose engineered cardiac tissue to an oxygen gradient that mimics the border zone and measured the effects of the gradient on electromechanical function and the transcriptome. The gradient delayed calcium release, reuptake, and propagation; decreased diastolic and peak systolic stress; and increased expression of inflammatory cascades that are hallmarks of myocardial infarction. These changes were distinct from those observed in tissues exposed to uniform normoxia or hypoxia, demonstrating distinct regulation of cardiac tissue phenotypes by an oxygen gradient. Our border-zone-on-a-chip model advances functional and mechanistic insight into oxygen-dependent cardiac tissue pathophysiology.