Michele de Nigris
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Michele de Nigris has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Abbate
RSE S.p.A.—Ricerca Sistema Energetico, Via Rubattino 54, 20134 Milan, Italy
1 shared publication - Filippo Dacarro
Experimental Techniques & Industrial Products Departments, European Centre for Training and Research in Earthquake Engineering (Eucentre), Pavia, Italy
1 shared publication - Francesco Cavalieri
European Centre for Training and Research in Earthquake Engineering (EUCENTRE), Pavia, Italy
1 shared publication - Giuseppe Donelli
Department of Civil Engineering and Architecture, University of Pavia, Via Ferrata 3, 27100 Pavia, Italy
1 shared publication - Leonardo Mancusi
RSE S.p.A.—Ricerca Sistema Energetico, Via Rubattino 54, 20134 Milan, Italy
1 shared publication - Nunzia Bernardo
Ricerca sul Sistema Energetico—RSE S.p.A., Via Rubattino 54, 20134 Milan, Italy
1 shared publication
Latest Publications
- Open Access
Risk of Powerline Failure Induced by Heavy Rainfall Hazards: Debris Flow Case Studies in Talamona and Campo Tartano
The power system is the backbone of the energy network, and overhead lines are its vital structures. Weather threats may jeopardise the reliability of lines and make them a weak link. In particular, heavy rainfall episodes can cause failures, especially in mountain areas. Current climate changes may exacerbate the effects on the ground, intensifying rainfall episodes and increasing the frequency of extreme events. In this context, debris flows triggered by rather intense precipitation and characterised by fast kinematics can destroy pylons and electric connections, affecting the infrastructures not only in the upper ridges but also downstream across the fan apex, where powerlines are much more distributed. This study presents an in-depth back-analysis of two debris flow events triggered in concomitance with a heavy cloudburst that occurred in Talamona (Sondrio Province, Italy) in July 2008 and in Campo Tartano (Sondrio Province, Italy) in April 2024. These events hit onsite powerlines, causing blackouts and showing the potential vulnerabilities of the local electricity system. An analysis of rainfall-induced landslide failure is carried out using the numerical model CRHyME (Climatic Rainfall Hydrogeological Modelling Experiment) and MIST-DF (Modelling Impulsive Sediment Transport—Debris Flow) with the aim of reconstructing the dynamics of the first (i.e., Talamona) geo-hydrological event. Powerline vulnerability is also investigated against debris flow dynamics, discussing possible strategies to reduce pylon exposure and to increase the resilience of the local electro-energetic network. Since, under climate change scenarios, heavy rainfall episodes are projected to intensify, an alternative approach based on rainfall-threshold curves is presented and applied to both cases of study. The latter, already implemented for civil protection purposes, could be useful in early-warning procedures against potential debris flow hazards. For both methodologies, the findings from the study confirm the strength of the approaches and foster their application in different situations (back-analysis and early warning) to reduce powerlines’ geo-hydrological risks.
Open AccessRisk of Powerline Failure Induced by Heavy Rainfall Hazards: Debris Flow Case Studies in Talamona and Campo Tartano
The power system is the backbone of the energy network, and overhead lines are its vital structures. Weather threats may jeopardise the reliability of lines and make them a weak link. In particular, heavy rainfall episodes can cause failures, especially in mountain areas. Current climate changes may exacerbate the effects on the ground, intensifying rainfall episodes and increasing the frequency of extreme events. In this context, debris flows triggered by rather intense precipitation and characterised by fast kinematics can destroy pylons and electric connections, affecting the infrastructures not only in the upper ridges but also downstream across the fan apex, where powerlines are much more distributed. This study presents an in-depth back-analysis of two debris flow events triggered in concomitance with a heavy cloudburst that occurred in Talamona (Sondrio Province, Italy) in July 2008 and in Campo Tartano (Sondrio Province, Italy) in April 2024. These events hit onsite powerlines, causing blackouts and showing the potential vulnerabilities of the local electricity system. An analysis of rainfall-induced landslide failure is carried out using the numerical model CRHyME (Climatic Rainfall Hydrogeological Modelling Experiment) and MIST-DF (Modelling Impulsive Sediment Transport—Debris Flow) with the aim of reconstructing the dynamics of the first (i.e., Talamona) geo-hydrological event. Powerline vulnerability is also investigated against debris flow dynamics, discussing possible strategies to reduce pylon exposure and to increase the resilience of the local electro-energetic network. Since, under climate change scenarios, heavy rainfall episodes are projected to intensify, an alternative approach based on rainfall-threshold curves is presented and applied to both cases of study. The latter, already implemented for civil protection purposes, could be useful in early-warning procedures against potential debris flow hazards. For both methodologies, the findings from the study confirm the strength of the approaches and foster their application in different situations (back-analysis and early warning) to reduce powerlines’ geo-hydrological risks.
- Open Access
- 14 December 2022
- Published by MDPI AG in Infrastructures
- Vol. 7 (12) , 171
Shake Table Testing of Voltage and Current Transformers and Numerical Derivation of Corresponding Fragility Curves
Damage to devices installed in electric substations, which have shown vulnerable behaviour under strong earthquakes in the last decades, may endanger power delivery in the emergency phases during and after an earthquake. Within seismic risk assessment of power networks, the definition of the fragility functions of electric equipment is paramount. However, in the current literature the availability of such fragility models for some specific electric substation components, including instrument transformers, is relatively limited, this being the reason behind the deployment of the current experimental and numerical research endeavour. Two voltage transformers and two current transformers having different system voltage levels (respectively in the high voltage HV and extra-high voltage EHV ranges) were subjected to shake table tests, and the experimental results were used to calibrate the corresponding 3D numerical models developed in OpenSees. A number of nonlinear dynamic analyses carried out within a multiple-stripe analysis (MSA) framework allowed the derivation of 16 fragility curves for the four transformers in both stand-alone and elevated/supported configurations, considering also two different soil types. Based on the derived curves, one of the voltage transformers is expected to experience light or negligible damage due to earthquake shaking, owing to its high resonance frequencies (and hence stiffness), whilst the remaining three devices may suffer moderate damage under medium to strong shaking intensities; however, their seismic risk is in effect mitigated by the presence of the typically employed supporting column. Comparison against models available in the literature lent valuable reassurance on the adequacy of the employed methodology and the reliability of the derived fragility curves.
- 14 December 2022
- Published by MDPI AG in Infrastructures
- Vol. 7 (12) , 171
Open AccessShake Table Testing of Voltage and Current Transformers and Numerical Derivation of Corresponding Fragility Curves
Damage to devices installed in electric substations, which have shown vulnerable behaviour under strong earthquakes in the last decades, may endanger power delivery in the emergency phases during and after an earthquake. Within seismic risk assessment of power networks, the definition of the fragility functions of electric equipment is paramount. However, in the current literature the availability of such fragility models for some specific electric substation components, including instrument transformers, is relatively limited, this being the reason behind the deployment of the current experimental and numerical research endeavour. Two voltage transformers and two current transformers having different system voltage levels (respectively in the high voltage HV and extra-high voltage EHV ranges) were subjected to shake table tests, and the experimental results were used to calibrate the corresponding 3D numerical models developed in OpenSees. A number of nonlinear dynamic analyses carried out within a multiple-stripe analysis (MSA) framework allowed the derivation of 16 fragility curves for the four transformers in both stand-alone and elevated/supported configurations, considering also two different soil types. Based on the derived curves, one of the voltage transformers is expected to experience light or negligible damage due to earthquake shaking, owing to its high resonance frequencies (and hence stiffness), whilst the remaining three devices may suffer moderate damage under medium to strong shaking intensities; however, their seismic risk is in effect mitigated by the presence of the typically employed supporting column. Comparison against models available in the literature lent valuable reassurance on the adequacy of the employed methodology and the reliability of the derived fragility curves.