Xiaoling Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiaoling Wang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Bojiao Yan
College of Visual Arts, Changchun Sci-Tech University, Changchun 130600, China
1 shared publication Chunyan Shi
Key Laboratory of Songliao Aquatic Environment, Ministry of Education, Jilin Jianzhu University, Changchun City, Jilin Province, P. R. China
1 shared publicationHai Lu
Key Laboratory of Songliao Aquatic Environment, Ministry of Education, Jilin Jianzhu University, Changchun City, Jilin Province, P. R. China
1 shared publication- Hai Lu
Key Laboratory of Songliao Aquatic Environment, Ministry of Education, Jilin Jianzhu University, Changchun 130118, China
1 shared publication - Jing Luo
School of Materials Science and Engineering, Jilin Jianzhu University, Changchun 130118, China
1 shared publication Wenbo Pan
Key Laboratory of Songliao Aquatic Environment, Ministry of Education, Jilin Jianzhu University, Changchun City, Jilin Province, P. R. China
1 shared publication
Latest Publications
- 14 March 2023
- Published by Springer Nature in Korean Journal of Chemical Engineering
- Vol. 40 (7) , 1661-1671
Variation in the quantity and composition of phosphorus accumulating organisms in activated sludge driven by nitrate-nitrogen
- 14 March 2023
- Published by Springer Nature in Korean Journal of Chemical Engineering
- Vol. 40 (7) , 1661-1671
Variation in the quantity and composition of phosphorus accumulating organisms in activated sludge driven by nitrate-nitrogen
- Open Access
Effect of Reactor Stages in Series in the Main Anoxic Section on Anoxic Phosphorus Absorption Performance of Modified A2O Process
Based on the kinetics of the treatment process of the completely mixed reactor in series, this study reveals the relationship between the reactor stages and the treatment efficiency, and it was applied to the simultaneous nitrogen and phosphorus removal process. The strengthening effect of the reactor stages of the main anoxic sections on the anoxic phosphorus absorption efficiency and the contribution to improving the treatment effect were investigated. Using sewage with a low carbon-to-nitrogen ratio as the research object and keeping the operation parameters of the improved anaerobic–anoxic–oxic (A2O) process unchanged, the experimental research was carried out under the condition that reactor stages in series of the main anoxic section were one, two, three and four, respectively. The results showed an increase in the number of reactors in series in the main anoxic zone. The total phosphorus (TP) concentration in the effluent of the main anoxic stage decreased significantly, and the phosphorus uptake increased from 4.411 g/d (when n; the number of reactor stages in series was one) to 5.086 g/d when n was 4. Additionally, the nitrate nitrogen (NO3−–N) concentration in the effluent decreased, from 12.53 mg/L when n was one, to 9.62 mg/L when n was four, the removal rate of total nitrogen (TN) increased, from 56.86% when n was one to 65.98% when n was four, and the reduction power of nitrate nitrogen increased, and the denitrification rate increased. The increase in the number of reactors in series enhanced the anoxic phosphorus absorption and denitrification performance. Therefore, the main anoxic section of the synchronous nitrogen and phosphorus removal system can be designed and operated as reactors in series.
Open AccessEffect of Reactor Stages in Series in the Main Anoxic Section on Anoxic Phosphorus Absorption Performance of Modified A2O Process
Based on the kinetics of the treatment process of the completely mixed reactor in series, this study reveals the relationship between the reactor stages and the treatment efficiency, and it was applied to the simultaneous nitrogen and phosphorus removal process. The strengthening effect of the reactor stages of the main anoxic sections on the anoxic phosphorus absorption efficiency and the contribution to improving the treatment effect were investigated. Using sewage with a low carbon-to-nitrogen ratio as the research object and keeping the operation parameters of the improved anaerobic–anoxic–oxic (A2O) process unchanged, the experimental research was carried out under the condition that reactor stages in series of the main anoxic section were one, two, three and four, respectively. The results showed an increase in the number of reactors in series in the main anoxic zone. The total phosphorus (TP) concentration in the effluent of the main anoxic stage decreased significantly, and the phosphorus uptake increased from 4.411 g/d (when n; the number of reactor stages in series was one) to 5.086 g/d when n was 4. Additionally, the nitrate nitrogen (NO3−–N) concentration in the effluent decreased, from 12.53 mg/L when n was one, to 9.62 mg/L when n was four, the removal rate of total nitrogen (TN) increased, from 56.86% when n was one to 65.98% when n was four, and the reduction power of nitrate nitrogen increased, and the denitrification rate increased. The increase in the number of reactors in series enhanced the anoxic phosphorus absorption and denitrification performance. Therefore, the main anoxic section of the synchronous nitrogen and phosphorus removal system can be designed and operated as reactors in series.