BLBo Liu

Bo Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bo Liu has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Microfluidic Production of Mangiferin-Loaded Liposomes Enables Gut–Joint Axis Modulation for Early Osteoarthritis Intervention

    by Yiqun Ren, Bing Wang, Bin Ran, Wenxin Li, Mian Li, Dan Liu, Jingyu Li, Luxu Yin, Jinxiang Han, Bo Liu, et al.

    Microfluidic nanomanufacturing provides a controllable and scalable strategy for improving the oral delivery of poorly bioavailable natural compounds. Herein, mangiferin-loaded liposomes (Lip@MG) were fabricated using an in-house-developed continuous microfluidic platform integrated with a high-efficiency micromixer and evaluated as a gut–joint axis-oriented intervention for early knee osteoarthritis (KOA). Compared with the conventional batch method, microfluidic synthesis produced Lip@MG with a more uniform spherical morphology, a clearly defined bilayer structure, and a narrower particle size distribution. By adjusting the flow-rate ratio, Lip@MG with tunable particle sizes from 207.8 to 118.6 nm, reduced polydispersity, and stable negative zeta potentials of up to approximately –35 mV was obtained. In vitro, Lip@MG exhibited favorable cytocompatibility and enhanced chondrocyte viability. Transcriptomic analysis, qRT-PCR, and western blot further indicated that Lip@MG attenuated LPS-induced inflammatory responses in chondrocytes, at least partly by suppressing NF-κB signaling and inhibiting p65 phosphorylation. In an anterior cruciate ligament transection-induced KOA mouse model, oral Lip@MG administration alleviated cartilage degeneration, increased cartilage thickness from 132 to 215 μm, reduced the OARSI score from 2.5 to 1.5, increased subchondral bone mineral density by 27%, and restored colonic barrier integrity, as reflected by a 65% reduction in the colonic histopathological score. Full-length 16S rRNA gene sequencing revealed that Lip@MG reshaped KOA-associated gut dysbiosis by partially restoring the Firmicutes/Bacteroidetes balance and enriching potentially beneficial taxa. These findings demonstrate that microfluidically manufactured Lip@MG is a promising nutritional nanocarrier for microbiota-centered early KOA intervention through coordinated regulation of intestinal homeostasis and joint degeneration.

  • Characterization of Thermo‐Mechanical Coupling and Heat Pipe Failure Analysis in the SAIRS Space Reactor

    by Zhangyi Du, Kaiwei Feng, Bo Liu, Zhan Wang, Chaowei Chen, Yan Chen

    This study establishes a three‐dimensional “SAIRS” heat pipe reactor model with integration of a sodium heat pipe model to investigate the heat transfer and mechanical performance of the core under steady‐state conditions. An irradiation swelling model for uranium nitride is incorporated into the heat pipe reactor to analyze the thermo‐mechanical behavior of the core at various burnup levels, as well as the impact of heat pipe failures at varying locations and quantities on the core's thermo‐mechanical performance is examined. The computational results indicate that, under steady‐state conditions, the core temperature gradually decreases radially, with a temperature difference of 216 K, while stress distribution is influenced by multiple factors. The hexagonal core design may lead to local thermal stress concentration at peripheral sharp corners of the core. As burnup increases, core temperature, deformation, and stress all rise, with the maximum stress increase reaching 54.6 MPa. Fuel experiences the most significant temperature and deformation increases, yet exhibits the smallest stress variation due to its elastic modulus. Changes in core temperature and stress depend on the location and spacing of failed heat pipes. When two central heat pipes fail, the localized temperature can reach 1812 K, whereas failures in peripheral heat pipes lead to higher system temperature rises. Wider spacing between failed heat pipes can mitigate localized overheating and stress concentration. The reactor can maintain fuel rod thermal stress below the yield limit through heat redistribution and regulation capabilities of adjacent functional heat pipes.

  • Open Access

    Enhanced microfluidic heat sinks with a bio-inspired metal skeleton toward thermal management of flexible electronics

    by Bo Liu, Encong Hu, Minyi Wang, Jiaqian Li, Ziman Wang, Gongming Xin, Xinyu Wang

  • Numerical Investigation of Flow Patterns and Mixing Characteristics in a 3D Micromixer with Helical Elements over Wide Reynolds Numbers

    by Bo Liu, Chaozhan Chen, Bin Ran, Liuyong Shi, Jiashen Wei, Jing Jin, Yonggang Zhu

    Micromixers play an important role in the micro total analysis systems (µTAS) that require rapid and effective mixing. However, current micromixers are usually designed to meet the need for mixing at limited Reynolds numbers. Herein, this paper presents a high‐performance 3D micromixer with helical elements over wide Reynolds numbers to achieve efficient mixing and has numerically investigated flow patterns and mixing characteristics accordingly. A coupled numerical model is built to analyze the flow pattern, mixing behavior, residence time distribution (RTD), and mixing performance of the 3D micromixer. Helical elements inside could greatly enhance a secondary flow and induce chaotic advection around. Dean vortices are observed in the micromixer, enormously shortening the RTD and promoting the related mixing effect. Furthermore, the effects of various geometric parameters are systematically investigated to optimize the performance of this 3D micromixer. The optimized micromixer shows excellent mixing ability over wide Reynolds numbers ranging from 0.01 to 2333.3, with an efficiency of over 94%. In addition, the numerical results are proved well consistent with analytical and experimental data correspondingly. Therefore, this work would potentially expand the use scope of 3D micromixers and provide a constructive strategy to develop essential parts involving the mixing or reacting process in µTAS.


  • High-Throughput Microfluidic Production of Bimetallic Nanoparticles on MXene Nanosheets and Application in Hydrogen Peroxide Detection

    by Bo Liu, Bin Ran, Chaozhan Chen, Liuyong Shi, Jing Jin, Yonggang Zhu

    Nanoparticle-functionalized transition-metal carbides and nitrides (MXenes) have attracted extensive attention in electrochemical detection owing to their excellent catalytic performance. However, the mainstream synthetic routes rely on the batch method requiring strict experimental conditions, generally leading to low yield and poor size tunability of particles. Herein, we report a high-throughput and continuous microfluidic platform for preparing a functional MXene (Ti3C2Tx) with bimetallic nanoparticles (Pt-Pd NPs) at room temperature. Two 3D micromixers with helical elements were integrated into the microfluidic platform to enhance the secondary flow for promoting transport and reaction in the synthesis process. The rapid mixing and strong vortices in these 3D micromixers prevent aggregation of NPs in the synthesis process, enabling a homogeneous distribution of Pt-Pd NPs. In this study, Pt-Pd NPs loaded on the MXene nanosheets were synthesized under various hydrodynamic conditions of 1-15 mL min-1 with controlled sizes, densities, and compositions. The mean size of Pt-Pd NPs could be readily controlled within the range 2.4-9.3 nm with high production rates up to 13 mg min-1. In addition, synthetic and electrochemical parameters were separately optimized to improve the electrochemical performance of Ti3C2Tx/Pt-Pd. Finally, the optimized Ti3C2Tx/Pt-Pd was used for hydrogen peroxide (H2O2) detection and shows excellent electrocatalytic activity. The electrode modified with Ti3C2Tx/Pt-Pd here presents a wide detection range for H2O2 from 1 to 12 000 μM with a limit of detection down to 0.3 μM and a sensitivity up to 300 μA mM-1 cm-2, superior to those prepared in the traditional batch method. The proposed microfluidic approach could greatly enhance the electrochemical performance of Ti3C2Tx/Pt-Pd, and sheds new light on the large-scale production and catalytic application of the functional nanocomposites.