T. Trupke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
T. Trupke has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
R. A. Bardos
University of New South Wales Centre of Excellence for Advanced Silicon Photovoltaics and Photonics Sydney 2052, Australia
2 shared publicationsA. Lorenz
Evergreen Solar
1 shared publicationAbbott
University of New South Wales, Sydney, 2052, NSW, Australia. Phone: +61 2 9385 4054, Fax: +61 2 9662 4240
1 shared publicationF.W. Chen
University of New South Wales, Sydney, 2052, NSW, Australia. Phone: +61 2 9385 4054, Fax: +61 2 9662 4240
1 shared publicationJ.E. Cotter
University of New South Wales, Sydney, 2052, NSW, Australia. Phone: +61 2 9385 4054, Fax: +61 2 9662 4240
1 shared publicationM. C. Schubert
Fraunhofer Institute for Solar Energy Systems , Heidenhofstrasse 2, D-79110 Freiburg, Germany
1 shared publication
Latest Publications
- 15 September 2006
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 100 (6) , 063531
Influence of photon reabsorption on quasi-steady-state photoluminescence measurements on crystalline silicon
The influence of reabsorption of spontaneously emitted photons within silicon samples on quasi-steady-state photoluminescence lifetime measurements and on implied current voltage curves obtained from photoluminescence is analyzed. It is shown that experimental artifacts resulting from reabsorption can generally be expected to be small and that they are expected only if the relative carrier density profile varies strongly with injection level. Such strong variations in the relative carrier density profile are shown to be expected only if the effective minority carrier lifetime varies with injection level over the range from 1to50μs which even then results in an under- or overestimation of the effective minority carrier lifetime by less than 20%.
- 15 September 2006
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 100 (6) , 063531
Influence of photon reabsorption on quasi-steady-state photoluminescence measurements on crystalline silicon
The influence of reabsorption of spontaneously emitted photons within silicon samples on quasi-steady-state photoluminescence lifetime measurements and on implied current voltage curves obtained from photoluminescence is analyzed. It is shown that experimental artifacts resulting from reabsorption can generally be expected to be small and that they are expected only if the relative carrier density profile varies strongly with injection level. Such strong variations in the relative carrier density profile are shown to be expected only if the effective minority carrier lifetime varies with injection level over the range from 1to50μs which even then results in an under- or overestimation of the effective minority carrier lifetime by less than 20%.
- Top Cited Papers
- 24 July 2006
- Published by AIP Publishing in Applied Physics Letters
- Vol. 89 (4) , 044107
Photoluminescence imaging of silicon wafers
Photoluminescence imaging is demonstrated to be an extremely fast spatially resolved characterization technique for large silicon wafers. The spatial variation of the effective minority carrier lifetime is measured without being affected by minority carrier trapping or by excess carriers in space charge regions, effects that lead to experimental artifacts in other techniques. Photoluminescence imaging is contactless and can therefore be used for process monitoring before and after individual processing stages, for example, in photovoltaics research. Photoluminescence imaging is also demonstrated to be fast enough to be used as an in-line tool for spatially resolved characterization in an industrial environment.
- 24 July 2006
- Published by AIP Publishing in Applied Physics Letters
- Vol. 89 (4) , 044107
Top Cited PapersPhotoluminescence imaging of silicon wafers
Photoluminescence imaging is demonstrated to be an extremely fast spatially resolved characterization technique for large silicon wafers. The spatial variation of the effective minority carrier lifetime is measured without being affected by minority carrier trapping or by excess carriers in space charge regions, effects that lead to experimental artifacts in other techniques. Photoluminescence imaging is contactless and can therefore be used for process monitoring before and after individual processing stages, for example, in photovoltaics research. Photoluminescence imaging is also demonstrated to be fast enough to be used as an in-line tool for spatially resolved characterization in an industrial environment.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1 (01608371) , 928-931
Fast Photoluminescence Imaging of Silicon Wafers
Photoluminescence (PL) imaging is demonstrated as a fast characterization tool allowing variations of the minority carrier lifetime within large area silicon wafers to be measured with high spatial resolution and with a data acquisition time of only one second. PL imaging is contactless and can therefore be applied to silicon solar cells before and after every processing stage including fully processed cells and bare, unpassivated mc-Si wafers, which makes it an extremely effective process monitoring tool that is ideally suited for inline applications in the PV industry. The combination of PL imaging with electroluminescence imaging and the application of PL imaging with external bias control are demonstrated to give very quick access to additional valuable information about local series resistance variations
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1 (01608371) , 928-931
Fast Photoluminescence Imaging of Silicon Wafers
Photoluminescence (PL) imaging is demonstrated as a fast characterization tool allowing variations of the minority carrier lifetime within large area silicon wafers to be measured with high spatial resolution and with a data acquisition time of only one second. PL imaging is contactless and can therefore be applied to silicon solar cells before and after every processing stage including fully processed cells and bare, unpassivated mc-Si wafers, which makes it an extremely effective process monitoring tool that is ideally suited for inline applications in the PV industry. The combination of PL imaging with electroluminescence imaging and the application of PL imaging with external bias control are demonstrated to give very quick access to additional valuable information about local series resistance variations
- 24 October 2005
- Published by AIP Publishing in Applied Physics Letters
- Vol. 87 (18) , 184102
Self-consistent calibration of photoluminescence and photoconductance lifetime measurements
An experimental method is introduced by which relative photoluminescence or photoconductance signals can be converted into an absolute excess carrier concentration. This method is demonstrated by comparison of self-consistently calibrated quasi-steady-state photoluminescence measurements with transient photoluminescence and with transient and quasi-steady-state photoconductance measurements on silicon samples. The method simplifies photoluminescence lifetime measurements and the recently introduced Suns-photoluminescence technique as it allows these techniques to be used in a self-contained way, without the previous requirement for a separate experimental technique for calibration. Important experimental observations regarding photoconductance lifetime measurements are also discussed.
- 24 October 2005
- Published by AIP Publishing in Applied Physics Letters
- Vol. 87 (18) , 184102
Self-consistent calibration of photoluminescence and photoconductance lifetime measurements
An experimental method is introduced by which relative photoluminescence or photoconductance signals can be converted into an absolute excess carrier concentration. This method is demonstrated by comparison of self-consistently calibrated quasi-steady-state photoluminescence measurements with transient photoluminescence and with transient and quasi-steady-state photoconductance measurements on silicon samples. The method simplifies photoluminescence lifetime measurements and the recently introduced Suns-photoluminescence technique as it allows these techniques to be used in a self-contained way, without the previous requirement for a separate experimental technique for calibration. Important experimental observations regarding photoconductance lifetime measurements are also discussed.