AVAkshay Venkatesh

Akshay Venkatesh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Akshay Venkatesh has a total of 57 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Origins of Aortic Coarctation: A Vascular Smooth Muscle Compartment Boundary Model

    by Christina L. Greene, Geoffrey Traeger, Akshay Venkatesh, David Han, Mark W. Majesky

    Compartment boundaries divide the embryo into segments with distinct fates and functions. In the vascular system, compartment boundaries organize endothelial cells into arteries, capillaries, and veins that are the fundamental units of a circulatory network. For vascular smooth muscle cells (SMCs), such boundaries produce mosaic patterns of investment based on embryonic origins with important implications for the non-uniform distribution of vascular disease later in life. The morphogenesis of blood vessels requires vascular cell movements within compartments as highly-sensitive responses to changes in fluid flow shear stress and wall strain. These movements underline the remodeling of primitive plexuses, expansion of lumen diameters, regression of unused vessels, and building of multilayered artery walls. Although the loss of endothelial compartment boundaries can produce arterial–venous malformations, little is known about the consequences of mislocalization or the failure to form SMC-origin-specific boundaries during vascular development. We propose that the failure to establish a normal compartment boundary between cardiac neural-crest-derived SMCs of the 6th pharyngeal arch artery (future ductus arteriosus) and paraxial-mesoderm-derived SMCs of the dorsal aorta in mid-gestation embryos leads to aortic coarctation observed at birth. This model raises new questions about the effects of fluid flow dynamics on SMC investment and the formation of SMC compartment borders during pharyngeal arch artery remodeling and vascular development.


  • Open Access

    Stromal cell-derived factor-encapsulated nanoparticles target ischemic myocardium and attenuate myocardial injury via proangiogenic effects

    by Shin Yajima, Seung Hyun Lee, Junkai Yang, Matthew D. Vergel, Manoj K. Manna, Sho Kusadokoro, Yuanjia Zhu, Stefan Elde, Danielle M. Mullis, Akshay Venkatesh, et al.


  • Open Access

    Origins of Aortic Coarctation: A Vascular Smooth Muscle Compartment Boundary Model

    by Christina L. Greene, Geoffrey Traeger, Akshay Venkatesh, David Han, Mark W. Majesky

    Compartment boundaries divide the embryo into segments with distinct fates and functions. In the vascular system, compartment boundaries organize endothelial cells into arteries, capillaries, and veins that are the fundamental units of a circulatory network. For vascular smooth muscle cells (SMCs) such boundaries produce mosaic patterns of investment based on embryonic origins with important implications for the non-uniform distribution of vascular disease later in life. Morphogenesis of blood vessels requires vascular cell movements within compartments as highly-sensitive responses to changes in fluid flow shear stress and wall strain. These movements underlie remodeling of primitive plexuses, expansion of lumen diameters, regression of unused vessels, and building multilayered artery walls. Although loss of endothelial compartment boundaries can produce arterial-venous malformations, little is known about the consequences of mislocalization or failure to form SMC origin-specific boundaries during vascular development. We propose that the failure to establish a normal compartment boundary between cardiac neural crest-derived SMCs of the 6th pharyngeal arch artery (future ductus arteriosus) and paraxial mesoderm-derived SMCs of the dorsal aorta in mid-gestation embryos leads to aortic coarctation observed at birth. This model raises new questions about the effects of fluid flow dynamics on SMC investment and the formation of SMC compartment borders during pharyngeal arch artery remodeling and vascular development.

  • Large Animal Translational Validation of 3 Mitral Valve Repair Operations for Mitral Regurgitation Using a Mitral Valve Prolapse Model: A Comprehensive In Vivo Biomechanical Engineering Analysis

    by Yuanjia Zhu, Shin Yajima, Matthew H. Park, Akshay Venkatesh, Charles J. Stark, Nicholas A. Tran, Sabrina K. Walsh, Sidarth Ethiraj, Robert J. Wilkerson, Luca E. Lin, et al.

    BACKGROUND: Various mitral repair techniques have been described. Though these repair techniques can be highly effective when performed correctly in suitable patients, limited quantitative biomechanical data are available. Validation and thorough biomechanical evaluation of these repair techniques from translational large animal in vivo studies in a standardized, translatable fashion are lacking. We sought to evaluate and validate biomechanical differences among different mitral repair techniques and further optimize repair operations using a large animal mitral valve prolapse model. METHODS: Male Dorset sheep (n=20) had P2 chordae severed to create the mitral valve prolapse model. Fiber Bragg grating force sensors were implanted to measure chordal forces. Ten sheep underwent 3 randomized, paired mitral valve repair operations: neochord repair, nonresectional leaflet remodeling, and triangular resection. The other 10 sheep underwent neochord repair with 2, 4, and 6 neochordae. Data were collected at baseline, mitral valve prolapse, and after each repair. RESULTS: All mitral repair techniques successfully eliminated regurgitation. Compared with mitral valve prolapse (0.54±0.18 N), repair using neochord (0.37±0.20 N; P =0.02) and remodeling techniques (0.30±0.15 N; P =0.001) reduced secondary chordae peak force. Neochord repair further decreased primary chordae peak force (0.21±0.14 N) to baseline levels (0.20±0.17 N; P =0.83), and was associated with lower primary chordae peak force compared with the remodeling (0.34±0.18 N; P =0.02) and triangular resectional techniques (0.36±0.27 N; P =0.03). Specifically, repair using 2 neochordae resulted in higher peak primary chordal forces (0.28±0.21 N) compared with those using 4 (0.22±0.16 N; P =0.02) or 6 neochordae (0.19±0.16 N; P =0.002). No difference in peak primary chordal forces was observed between 4 and 6 neochordae ( P =0.05). Peak forces on the neochordae were the lowest using 6 neochordae (0.09±0.11 N) compared with those of 4 neochordae (0.15±0.14 N; P =0.01) and 2 neochordae (0.29±0.18 N; P =0.001). CONCLUSIONS: Significant biomechanical differences were observed underlying different mitral repair techniques in a translational large animal model. Neochord repair was associated with the lowest primary chordae peak force compared to the remodeling and triangular resectional techniques. Additionally, neochord repair using at least 4 neochordae was associated with lower chordal forces on the primary chordae and the neochordae. This study provided key insights about mitral valve repair optimization and may further improve repair durability.


  • Open Access

    NEXT-GENERATION SEQUENCING IN COVID-19 ANALYSIS

    by S. Narendra Kumar, Ajeet Kumar Srivastava, Lingayya Hiremath, Akshay Venkatesh, Pallavi M.D, Yuktha K.M, Maloshka P.

    Next generation sequencing is a high throughput sequencingtechnology that can be used for diagnostic purposes. This review discusses the use of next generation sequencing technology for the detection and analysis of SARS-CoV-2. There are different parameters to be considered while comparing next generation sequencing technology to more traditional methods of testing. The review also includes the various mutations and evolutions undergone by the virus across the population during the pandemic. This review addresses the methodology, analysis and processing of next generation sequencing in the analysis of SARS-CoV-2 along with other relevant aspects.

  • Open Access

    Three-Dimensional Bioprinting with Alginate by Freeform Reversible Embedding of Suspended Hydrogels with Tunable Physical Properties and Cell Proliferation

    by Yuanjia Zhu, Charles J. Stark, Sarah Madira, Sidarth Ethiraj, Akshay Venkatesh, Shreya Anilkumar, Jinsuh Jung, Seunghyun Lee, Catherine A. Wu, Sabrina K. Walsh, et al.

    Extrusion-based three-dimensional (3D) bioprinting is an emerging technology that allows for rapid bio-fabrication of scaffolds with live cells. Alginate is a soft biomaterial that has been studied extensively as a bio-ink to support cell growth in 3D constructs. However, native alginate is a bio-inert material that requires modifications to allow for cell adhesion and cell growth. Cells grown in modified alginates with the RGD (arginine-glycine-aspartate) motif, a naturally existing tripeptide sequence that is crucial to cell adhesion and proliferation, demonstrate enhanced cell adhesion, spreading, and differentiation. Recently, the bioprinting technique using freeform reversible embedding of suspended hydrogels (FRESH) has revolutionized 3D bioprinting, enabling the use of soft bio-inks that would otherwise collapse in air. However, the printability of RGD-modified alginates using the FRESH technique has not been evaluated. The associated physical properties and bioactivity of 3D bio-printed alginates after RGD modification remains unclear. In this study, we characterized the physical properties, printability, and cellular proliferation of native and RGD-modified alginate after extrusion-based 3D bioprinting in FRESH. We demonstrated tunable physical properties of native and RGD-modified alginates after FRESH 3D bioprinting. Sodium alginate with RGD modification, especially at a high concentration, was associated with greatly improved cell viability and integrin clustering, which further enhanced cell proliferation.