Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Azka Rehman has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Opportunistic Screening of Carotid Atherosclerosis and Cardiovascular Mortality Risk Using Chest Radiographs: A Comparative Study of Foundation Models

    by Azka Rehman, Jaewon Kim, Hyeokjong Lee, Jooyoung Chang, Sang Min Park

    Background: Cardiovascular disease (CVD) remains a leading cause of death, but population‐level screening for atherosclerosis often depends on specialized imaging that is not routinely available. We evaluated foundation models for opportunistic detection of carotid atherosclerosis from chest radiographs, assessed the prognostic value of the resulting biomarker for CVD death, and examined model explainability. Methods: Among 5785 participants with carotid sonography annotations, we compared Rad‐DINO, DINOv2, OpenCLIP, and CheXagent for chest radiograph–based atherosclerosis detection using linear probing, selective fine‐tuning, and low‐rank adaptation. Performance was assessed by area under the receiver operating characteristic curve with 95% CIs. Explainability was evaluated using gradient‐weighted class activation mapping and a clinical relevance index, which quantified attention within cardiovascular anatomic masks. The selected model generated a Deep‐Learning Chest X‐Ray Atherosclerosis Score, which was tested for association with CVD death in 32 524 participants using Framingham Risk Score–adjusted Cox models. Results: Rad‐DINO achieved the highest performance with selective fine‐tuning (area under the receiver operating characteristic curve, 0.74 [95% CI, 0.71–0.77]) and low‐rank adaptation (area under the receiver operating characteristic curve, 0.74 [95% CI, 0.70–0.76]), with the highest anatomic relevance under low‐rank adaptation (clinical relevance index, 0.31). Higher Deep‐Learning Chest X‐Ray Atherosclerosis Score tertiles were strongly associated with CVD death (adjusted hazard ratio, 9.36 [95% CI, 3.35–26.15] for high versus low; P ‐trend<0.005). The model concordance index was 0.73 (95% CI, 0.67–0.75). Conclusions: Foundation models enable opportunistic detection of carotid atherosclerosis from chest radiographs and yield a biomarker that provides prognostic information for CVD death. Explainability analyses demonstrated alignment with CVD anatomic regions, supporting clinical relevance and scalable risk stratification.

  • Open Access

    SA-AVAE: A sex-Aware adversarial variational autoencoder network for biological brain age estimation in IoMT-Enabled multimodal neuroimages

    by Abd Ur Rehman, Azka Rehman, Muhammad Umar Farooq, Taehyun Lee, Tariq M. Khan, Imran Razzak, Sung-Min Gho, Aleum Lee, Dong-Kyu Chae, Muhammad Usman


  • Open Access

    Biological Brain Age Estimation using Sex-Aware Adversarial Variational Autoencoder with Multimodal Neuroimages

    by Abd Ur Rehman, Azka Rehman, Muhammad Usman, Abdullah Shahid, Sung-Min Gho, Aleum Lee, Tariq M. Khan, Imran Razzak

    Brain aging involves structural and functional changes and therefore serves as a key biomarker for brain health. Combining structural magnetic resonance imaging (sMRI) and functional magnetic resonance imaging (fMRI) has the potential to improve brain age estimation by leveraging complementary data. However, fMRI data, being noisier than sMRI, complicates multimodal fusion. Traditional fusion methods often introduce more noise than useful information, which can reduce accuracy compared to using sMRI alone. In this paper, we propose a novel multimodal framework for biological brain age estimation, utilizing a sex-aware adversarial variational autoencoder (SA-AVAE). Our framework integrates adversarial and variational learning to effectively disentangle the latent features from both modalities. Specifically, we decompose the latent space into modality-specific codes and shared codes to represent complementary and common information across modalities, respectively. To enhance the disentanglement, we introduce cross-reconstruction and shared-distinct distance ratio loss as regularization terms. Importantly, we incorporate sex information into the learned latent code, enabling the model to capture sex-specific aging patterns for brain age estimation via an integrated regressor module. We evaluate our model using the publicly available OpenBHB dataset, a comprehensive multi-site dataset for brain age estimation. The results from ablation studies and comparisons with state-of-the-art methods demonstrate that our framework outperforms existing approaches and shows significant robustness across various age groups, highlighting its potential for real-time clinical applications in the early detection of neurodegenerative diseases.

  • Advancing Metaverse-Based Healthcare With Multimodal Neuroimaging Fusion via Multi-Task Adversarial Variational Autoencoder for Brain Age Estimation

    by Muhammad Usman, Azka Rehman, Abdullah Shahid, Abd Ur Rehman, Sung-Min Gho, Aleum Lee, Tariq M. Khan, Imran Razzak

    The metaverse, which integrates physical and virtual realities through technologies such as high-speed internet, virtual and augmented reality, and artificial intelligence (AI), offers transformative prospects across various fields, particularly healthcare. This integration introduces a new paradigm in AI-driven medical imaging, particularly in assessing brain age'a crucial marker for detecting age-related neuropathologies such as Alzheimer's disease (AD) using magnetic resonance imaging (MRI). Despite advances in deep learning for estimating brain age from structural MRI (sMRI), incorporating functional MRI (fMRI) data presents significant challenges due to its complex data structure and the noisy nature of functional connectivity measurements. To address these challenges, we present the Multitask Adversarial Variational Autoencoder (M-AVAE), a bespoke deep learning framework designed to enhance brain age predictions through multimodal MRI data integration. The M-AVAE uniquely separates latent variables into generic and unique codes, effectively isolating shared and modality-specific features. Additionally, integrating multitask learning with sex classification as a supplementary task enables the model to account for sex-specific aging nuances. Evaluated on the OpenBHB dataset'a comprehensive multisite brain MRI aggregation-the M-AVAE demonstrates exceptional performance, achieving a mean absolute error of 2.77 years, surpassing conventional methodologies. This success positions M-AVAE as a powerful tool for metaverse-based healthcare applications in brain age estimation. The source code is made publicly available at: https://github.com/engrussman/MAVAE .


  • Open Access

    Selective Deeply Supervised Multi-Scale Attention Network for Brain Tumor Segmentation

    by Azka Rehman, Muhammad Usman, Abdullah Shahid, Siddique Latif, Junaid Qadir

    Brain tumors are among the deadliest forms of cancer, characterized by abnormal proliferation of brain cells. While early identification of brain tumors can greatly aid in their therapy, the process of manual segmentation performed by expert doctors, which is often time-consuming, tedious, and prone to human error, can act as a bottleneck in the diagnostic process. This motivates the development of automated algorithms for brain tumor segmentation. However, accurately segmenting the enhanced and core tumor regions is complicated due to high levels of inter- and intra-tumor heterogeneity in terms of texture, morphology, and shape. This study proposes a fully automatic method called the selective deeply supervised multi-scale attention network (SDS-MSA-Net) for segmenting brain tumor regions using a multi-scale attention network with novel selective deep supervision (SDS) mechanisms for training. The method utilizes a 3D input composed of five consecutive slices, in addition to a 2D slice, to maintain sequential information. The proposed multi-scale architecture includes two encoding units to extract meaningful global and local features from the 3D and 2D inputs, respectively. These coarse features are then passed through attention units to filter out redundant information by assigning lower weights. The refined features are fed into a decoder block, which upscales the features at various levels while learning patterns relevant to all tumor regions. The SDS block is introduced to immediately upscale features from intermediate layers of the decoder, with the aim of producing segmentations of the whole, enhanced, and core tumor regions. The proposed framework was evaluated on the BraTS2020 dataset and showed improved performance in brain tumor region segmentation, particularly in the segmentation of the core and enhancing tumor regions, demonstrating the effectiveness of the proposed approach. Our code is publicly available.


  • Open Access

    MEDS-Net: Self-Distilled Multi-Encoders Network with Bi-Direction Maximum Intensity projections for Lung Nodule Detection

    by Muhammad Usman, Azka Rehman, Abdullah Shahid, Siddique Latif, Shi Sub Byon, Byoung Dai Lee, Sung Hyun Kim, Byung Il Lee, Yeong Gil Shin

    In this study, we propose a lung nodule detection scheme which fully incorporates the clinic workflow of radiologists. Particularly, we exploit Bi-Directional Maximum intensity projection (MIP) images of various thicknesses (i.e., 3, 5 and 10mm) along with a 3D patch of CT scan, consisting of 10 adjacent slices to feed into self-distillation-based Multi-Encoders Network (MEDS-Net). The proposed architecture first condenses 3D patch input to three channels by using a dense block which consists of dense units which effectively examine the nodule presence from 2D axial slices. This condensed information, along with the forward and backward MIP images, is fed to three different encoders to learn the most meaningful representation, which is forwarded into the decoded block at various levels. At the decoder block, we employ a self-distillation mechanism by connecting the distillation block, which contains five lung nodule detectors. It helps to expedite the convergence and improves the learning ability of the proposed architecture. Finally, the proposed scheme reduces the false positives by complementing the main detector with auxiliary detectors. The proposed scheme has been rigorously evaluated on 888 scans of LUNA16 dataset and obtained a CPM score of 93.6\%. The results demonstrate that incorporating of bi-direction MIP images enables MEDS-Net to effectively distinguish nodules from surroundings which help to achieve the sensitivity of 91.5% and 92.8% with false positives rate of 0.25 and 0.5 per scan, respectively.