CAChristopher N. Andrews

Christopher N. Andrews

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Christopher N. Andrews has a total of 187 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Letter to the Editor: Response to “Evaluation of Body Surface Gastric Mapping Phenotypes for Gastroduodenal Disorders: Ten Points for Discussion”

    by Gregory O'Grady, Chris Varghese, Thomas L. Abell, Armen Gharibans, Christopher N. Andrews, the BSGM Technical Group

  • Response to: Pairing the Auckland Classification With a Brief Psychosocial Context Layer

    by Mikaela Law, Christopher N. Andrews, Greg O'GRady

  • Open Access

    Artificial Intelligence in Gastrointestinal Motility Diagnostics: A Systematic Review

    by Dylan Muggleston, Greg O'GRady, Chris Varghese, Christopher Andrews

    Background: The assessment of gastrointestinal (GI) motility disorders is limited by the invasive, resource‐intensive, and subjective nature of current testing. Artificial Intelligence (AI) is being applied to address these challenges. This review aimed to comprehensively identify, appraise, and synthesize the spectrum of AI applications in GI motility diagnostics. Methods: A systematic search of PubMed, Embase, Scopus, Web of Science, and Medline for original studies was conducted in March 2025. Results were narratively synthesized and grouped by anatomic region. Key Results: Of 1383 articles, 90 primary studies met the inclusion criteria. In the esophagus ( n = 31), the primary focus was automation of High‐Resolution Esophageal Manometry (HREM), pH impedance, and Functional Luminal Imaging Probe (FLIP) panometry analysis. In the gastroduodenum ( n = 21), studies looked to improve diagnostic accuracy and interpretability of legacy electrogastrography (EGG). In the small and large intestine ( n = 19), AI was used to determine transit time and predict post‐operative ileus. In the anorectum ( n = 9), tools focused on standardizing manometry interpretation. Review of pan‐GI applications ( n = 10) highlighted AI's application to wireless capsule endoscopy and bowel sounds analysis. While promising, all areas need more rigorous research and external validation before widespread deployment. Conclusions and Inferences: AI will play an essential role in improving and automating the interpretation of GI motility diagnostics. However, even the most promising models require large‐scale prospective validation before clinical implementation. Trial Registration: PROSPERO (ID: 1128662)


  • Open Access

    Navigating Care Amid Crisis: The Impact of the COVID-19 Pandemic on Eosinophilic Esophagitis Management in Canada

    by Sunil Samnani, Muhammad Anas Fazal, Krystyna Pokraka, Joel David, Christopher N. Andrews, Michelle Buresi, Dorothy Y. Li, Matthew Woo, Christopher Ma, Milli Gupta

    Background and Objectives: The COVID-19 pandemic caused significant disruptions in healthcare services. Foreign body impactions (FBIs), with Eosinophilic Esophagitis (EoE) being one of the leading underlying causes in adults, are some of the most common emergencies and often require endoscopy. The study assesses the impact of COVID-19 on the incidence and outcomes of foreign body impactions (FBIs) requiring endoscopy at Canadian tertiary centres in a single city. Methods: Patients presenting to tertiary care hospital emergency departments in Calgary (March 2019–Feb 2022) for FBI were identified using the AACRS (Alberta Ambulatory Care Reporting System) database using International Classification of Disease (ICD-9 and ICD-10) codes (T178, T181) and provincial diagnostic codes (935.1, 530.4) for a foreign body in the esophagus (530.13 and K20.0). One-way ANOVA (SPSS® 27.0) analyzed incidence and disease progression across Pre-COVID-19 and COVID-19 years. Results: 759 patients were included in the analysis (274 Pre-COVID-19 (PC: March 2019–Feb 2020), 234 COVID-19 Year 1 (CY1: March 2020–Feb 2021), and 251 COVID-19 Year 2 (CY2: March 2021–Feb 2022)). The mean age remained consistent, with two-thirds being male. Food was the predominant type of FBI (>90%). The incidence of new EoE in EDs declined from PC (60.9%) to CY1 (47.4%) (p < 0.001), while endoscopic resolution remained >96%. Follow-up endoscopies in outpatient settings remained stable (~60%). Non-EoE causes of FBI, including esophagitis and cancer, increased in CY2. The mean ED length of stay rose in CY2, but this was not statistically significant (p = 0.06). Conclusions: This study highlights the resilience of emergent endoscopic care in Calgary during COVID, despite a decline in new EoE diagnoses, which might be due to access barriers.

  • Open Access

    Glucagon-like Peptide-1 Agonist Liraglutide Induces Temporary Impairment to Gastric Electrical Activity in Healthy Volunteers

    by Schynell Coutinho, Chris Varghese, Eric Buenz, Stefan Calder, Armen Gharibans, Greg O’GRady, Charlotte Daker, Christopher N. Andrews


  • Spectrum of Interstitial Cell of Cajal Deficits in Chronic Gastroduodenal Disorders: Systematic Review and Meta-Analysis

    by Chris Varghese, Pankaj J. Pasricha, Thomas L. Abell, Henry P. Parkman, Christopher N. Andrews, Daniel Keszthelyi, Armen A. Gharibans, Gianrico Farrugia, Greg O'GRady

    INTRODUCTION: Chronic neurogastroduodenal disorders are heterogeneous and thought to lie on a spectrum of disease encompassing both sensory and neuromuscular pathologies. Abnormalities of interstitial cells of Cajal (ICC), a subset of which generate pacemaker signals and subsequently motility, have been implicated in their pathophysiology. We systematically reviewed the literature to pool ICC deficits observed in chronic neurogastroduodenal disorders. METHODS: Studies quantifying gastric ICC from the corpus or antrum, in adult patients with gastroparesis, functional dyspepsia (FD), or chronic nausea and vomiting syndromes (CNVS) were analyzed (PROSPERO: CRD42024613226). MEDLINE, Embase and CENTRAL databases were searched systematically. Random effects meta-analyses were used to compare ICC counts by disorder group with subgroup analysis by quantification methodology. RESULTS: Overall, 2,158 studies were screened and 22 included. Comparative studies (n = 12) showed patients with chronic neurogastroduodenal disorders (n = 167 with gastroparesis, n = 19 with FD ± CNVS) had lower ICC counts than nondiabetic controls (n = 130); standardized mean difference −1.58, 95% confidence interval −2.09 to −1.07, P < 0.0001, with more severe deficits in gastroparesis compared to FD ± CNVS (standardized mean difference [SMD] −0.44, P = 0.048). A spectrum of ICC deficits was evident in a subgroup of studies using gold-standard methods with c-KIT antibody and 4',6-diamidino-2-phenylindole-stained nuclei confirmation (7 studies, 246 patients: mean ICC counts 2.29 in gastroparesis vs 3.49 in FD ± CNVS, and 5.27 in controls; P < 0.001 all comparisons). Most studies were at high risk of bias (n = 21). DISCUSSION: Marked depletion of ICC is a consistent finding in neurogastroduodenal disorders. A spectrum of disease is revealed, with greater depletion associated with delayed emptying. Techniques for clinically defining ICC-driven gastric neuromuscular dysfunction should be prioritized.


  • Predictors of Outcomes After Gastric Peroral Endoscopic Myotomy for Refractory Gastroparesis: A Systematic Review

    by Chris Varghese, Alexandria Lim, Charlotte Daker, Gabrielle Sebaratnam, Armen A. Gharibans, Christopher N. Andrews, William L. Hasler, Greg O'GRady

    INTRODUCTION: Gastroparesis is a debilitating gastroduodenal disorder for which gastric peroral endoscopic myotomy (GPOEM) has emerged as an efficacious treatment option. However, response to GPOEM varies between 50% and 80%, such that preoperative predictors of treatment success are needed to guide patient selection. METHODS: We performed a systematic review to identify predictors of clinical and functional response to GPOEM among adult patients with gastroparesis (PROSPERO: CRD42023457359). MEDLINE, Embase, and CENTRAL databases were searched systematically for studies reporting outcomes after GPOEM in September 2023. A narrative synthesis of predictive factors on univariable and multivariable analysis was performed with consideration of response rates through meta-analysis and evaluation of discrimination if prognostic models were developed. Risk Of Bias In Non-randomized Studies - of Exposures (ROBINS-E) was used for risk of bias assessment. RESULTS: Of 1899 articles reviewed, 30 were included. The GPOEM response rate was 63.1% (95% confidence interval 56.3%–69.5%) with most studies defining clinical success on the basis of improvement in gastroparesis cardinal symptom index (87%, 26/30). Older age, shorter duration of gastroparesis, nondiabetic etiology, lower body mass index, and response to intrapyloric botulinum toxin were associated with positive response to GPOEM on multivariable analyses. Predictors on physiological tests such as EndoFLIP or gastric emptying scintigraphy were inconsistent. No prognostic models underwent external validation. DISCUSSION: Currently, there are limited reproducible predictors of response to GPOEM among patients with refractory gastroparesis. Robust prospective studies investigating scalable, reproducible, and actionable biomarkers of treatment response are required.


  • Open Access

    Spatially and temporally precise microbiome profiling in the small intestine using the SIMBA capsule with X-ray tracking

    by Gang Wang, Sharanya Menon, Lynn Wilsack, Renata Rehak, Lawrence Lou, Christian Turbide, Jeremie Auger, Annie Tremblay, Olivier Mathieu, Sylvie Binda, et al.

    Introduction: Few minimally invasive options for sampling the small intestinal (SI) luminal fluid exist to study the SI microbiota in health and disease. To address the lack of tools and methods to study GI regions that are difficult to access, Nimble Science developed a fully autonomous and passive sampling method, the Small Intestine MicroBiome Aspiration (SIMBA™) capsule, for convenient, high-quality, and reliable sampling to study the diet-microbiota interactions in the SI. Methods: The sealing efficacy and microbial DNA preservation capacity of the SIMBA capsules was first validated through in vitro simulation assays. Then, a clinical study was conducted with 20 healthy participants to validate the in vivo use of SIMBA capsules to reliably capture samples for SI microbiome analysis before and after an intervention (NCT04489329). Briefly, participants ingested the capsules at baseline and 7 days later, with a probiotic capsule containing a blend of L. rhamnosus R0011 and B. longum R0175. Following baseline SIMBA capsule ingestion, multiple low-dosage x-ray scans were performed to track the sampling location. Fecal samples corresponding with the baseline and intervention capsule were analyzed for comparison. Results: The SIMBA capsules’ performance in vitro demonstrated the potential for contamination-free sampling with preservation of the microbial communities. Within the clinical study, the capsules performed safely and reliably for collection of SI content. X-ray tracking confirmed that 97.2% of the capsules completed sample collection in the SI regions before reaching the colon. Importantly, our data showed that the capsules sampled in the right area of the intestines and that baseline SIMBA microbiome profile is significantly different from fecal microbiome profile. SIMBA successfully detected a concurrent probiotic intervention in the small intestine, which was not detectable using stool samples. Discussions: The high accuracy of sampling location and sealing efficacy of the SIMBA capsules makes them potentially useful research tools in clinical trials for studying diet-microbiota interactions in health and disease, and perhaps eventually for the clinical diagnosis of GI tract conditions affecting the SI such as SIBO.


  • Open Access

    CLINICAL SAMPLING OF SMALL INTESTINE LUMINAL CONTENT FOR MICROBIOME MULTI-OMICS ANALYSIS: A PERFORMANCE ANALYSIS OF THE SMALL INTESTINE MICROBIOME ASPIRATION (SIMBA) CAPSULE AND BENCHMARKING AGAINST ENDOSCOPY

    by Gang Wang, Cedoljub Bundalovic-Torma, Sharanya Menon, Sabina Bruehlmann, Lynn Wilsack, Renata Rehak, Sahar Bagheri, Mohammad M. Banoei, Lawrence Lou, Yasmin Nasser, et al.

    Objective: The small intestine (SI) microbiome is increasingly implicated in both functional gastrointestinal (GI) disorders and a wide range of systemic diseases. However, owing to limitations of traditional GI sampling approaches, the SI remains challenging to directly access on a large scale. This work presents the Small Intestinal MicroBiome Aspiration Capsule (SIMBA) as an effective means for sampling SI luminal content. Design: In an observational clinical study, SIMBA capsules were ingested by both healthy individuals and Irritable Bowel Syndrome (IBS) patients on two successive visits. On a first visit, X-ray scans were used to evaluate SI targeting accuracy. On a second visit, SIMBA capsule ingestion was paired with duodenal endoscopy and saliva samples for reference. For both visits, SIMBA capsules were retrieved with matching fecal samples to evaluate effective sealing during GI transit. Results: X-ray monitoring confirmed all capsules sampled from the distal small intestine with a few (5 of 49) sealing in the proximal colon. Overall, 94% of capsules were retrieved by subjects with median total gut transit time of 47 hours (IQR 24-54). Capsule sampling location and duration was also not significantly affected by IBS. Multi-omics analysis showed that microbiota and metabolomic composition of SIMBA capsules were significantly different to fecal samples, and similar to endoscopic aspirate and cytological brush sampling. Conclusions: The SIMBA capsule reliably captures and preserves SI luminal fluid in a clinically relevant context that is suitable for multi-omics data analysis, comparable to duodenal aspirate, and complements fecal sampling in its broad applicability of use. KEY MESSAGES: What is already known on this topic Research into the gastrointestinal (GI) microbiome and its role in health and disease is almost completely biased towards the colon due to the reliance on fecal sampling. Owing to the lack of reliable and scalable sampling approaches, our knowledge of the small intestine (SI) microbiome is significantly lagging by comparison. What this study adds This study presents the Small Intestine Microbiome Aspiration (SIMBA) capsule which targets the distal SI in a reliable and reproducible fashion and collects high-quality multi-omics datasets that are on par with “gold-standard” endoscopic sampling. The SIMBA capsule was compared against established sampling methodologies, providing a multi-omics glimpse into the entire biogeographic diversity of the GI tract, revealing substantial and biologically meaningful differences in both microbiome and metabolic profiles that reinforce the significant difference between SI and feces. Overall, the SIMBA capsule demonstrates clear and reproducible differences in microbiome composition of the SI that is otherwise lacking from traditionally used fecal sampling. How this study might affect research, practice or policy The SIMBA capsule collects high-quality multi-omics datasets that will enable significant insights into the SI microbiome function in health and disease and is ideal for use in research, large-scale clinical or population studies, and diagnostic applications.


  • Open Access

    Spatially and Temporally Precise Microbiome Profiling in the Small Intestine using the SIMBA Capsule with X-ray tracking

    by Gang Wang, Sharanya Menon, Lynn Wilsack, Renata Rehak, Lawrence Lou, Christian Turbide, Jeremie Auger, Annie Tremblay, Olivier Mathieu, Sylvie Binda, et al.

    Few minimally invasive options for sampling the small intestinal (SI) luminal fluid exist to study the SI microbiota in health and disease. To address the lack of tools and methods to study GI regions that are difficult to access, Nimble Science developed a fully autonomous and passive sampling method, the Small Intestine MicroBiome Aspiration (SIMBA TM ) capsule, for convenient, high-quality, and reliable sampling to study the diet-microbiota interactions in the SI. The sealing efficacy and microbial DNA preservation capacity of the SIMBA capsules was first validated through in vitro simulation assays. Then, a clinical study was conducted with 20 healthy participants to validate the in vivo use of SIMBA capsules to reliably capture samples for SI microbiome analysis before and after an intervention ( NCT04489329 ). Briefly, participants ingested the capsules at baseline and 7 days later, with a probiotic capsule containing a blend of L. rhamnosus R0011 and B. longum R0175. Following baseline SIMBA capsule ingestion, multiple low-dosage x-ray scans were performed to track the sampling location. Fecal samples corresponding with the baseline and intervention capsule were analyzed for comparison. The SIMBA capsules’ performance in vitro demonstrated the potential for contamination-free sampling with preservation of the microbial communities. Within the clinical study, the capsules performed safely and reliably for collection of SI content. X-ray tracking confirmed that 97.2% of the capsules completed sample collection in the SI regions before reaching the colon. Importantly, our data showed that the capsules sampled in the right area of the intestines and that baseline SIMBA microbiome profile is significantly different from fecal microbiome profile. SIMBA successfully detected a concurrent probiotic intervention in the small intestine, which was not detectable using stool samples. The high accuracy of sampling location and sealing efficacy of the SIMBA capsules makes them potentially useful research tools in clinical trials for studying diet-microbiota interactions in health and disease, and perhaps eventually for the clinical diagnosis of GI tract conditions affecting the SI such as SIBO.