MAMohamed A. Abdelshakour

Mohamed A. Abdelshakour

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mohamed A. Abdelshakour has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Environment‐Friendly High‐Performance Liquid Chromatography Method for Simultaneous Determination of Six Drugs Used for Common Cold Treatment in Different Pharmaceutical Dosage Forms

    by Alaa A. El‐Waey, Mostafa I. Abdelglil, Randa A. Abdel Salam, Ghada M. Hadad, Alaa El‐Gindy, Mohamed A. Abdelshakour

    A sustainable and environmentally benign reversed‐phase high‐performance liquid chromatography method was developed for the simultaneous determination of six widely used anti‐cold drugs: pseudoephedrine hydrochloride, paracetamol, caffeine, cetirizine dihydrochloride, guaifenesin, and ibuprofen. The method was designed in accordance with green analytical chemistry concepts, allowing the simultaneous analysis of multiple components in a single chromatographic run within a short analysis time. Notably, the procedure eliminates the need for derivatization or prior sample preparation and operates with relatively low energy requirements. Chromatographic separation and quantification were achieved using a reversed‐phase C18 column. The mobile phase system consisted of ethanol as solvent A and 0.1% aqueous acetic acid as solvent B, delivered through a simple gradient elution program at a flow rate of 1.2 mL/min. Detection was performed using an ultraviolet detector set at 215 nm. Validation of the developed method was carried out following International Council for Harmonization guidelines, confirming its linearity, selectivity, sensitivity, accuracy, precision, and robustness. The applicability of the method was demonstrated through successful analysis of 12 different pharmaceutical formulations, including tablets, capsules, and oral drops. The results showed excellent selectivity and accuracy, with no interference observed from common excipients. Overall, the proposed method offers a reliable and environmentally friendly alternative for routine quality control analysis of the investigated drugs. Evaluation of its environmental impact using the National Environmental Methods Index, Green Analytical Procedure Index, and Analytical GREEnness Metric Approach tools revealed a high level of greenness, with an Eco‐Scale score of 92, indicating excellent environmental compatibility.

  • Eco-Friendly UV-Spectrophotometric Methods Employing Magnetic Nano-Composite Polymer for the Extraction and Analysis of Sexual Boosters in Adulterated Food Products: Application of Computer-Aided Design

    by Mohamed A Abdelshakour, Khaled Attala, Ahmed Elsonbaty, Randa A Abdel Salam, Ghada M Hadad, Aziza E Mostafa, Maya S Eissa

    Background: Solid phase extraction (SPE) techniques, based on computationally designed magnetic-based multi-targeting molecular imprinted polymer (MT-MIP), combined with UV spectrophotometric approaches provide advantages in the examination of counterfeit samples. Objective: The current work describes an innovative and sustainable methodology for the simultaneous determination of tadalafil (TAD) and dapoxetine hydrochloride (DAP) in aphrodisiac counterfeit products (honey and instant coffee) utilizing SPE exploiting MT-MIP. Additionally, an innovative UV spectrophotometric method capable of resolving TAD in its pharmaceutical binary mixtures with DAP was developed. A novel computational approach was implemented to tailor the synthesis and design of the MT-MIP particles. Methods: We applied a newly developed UV spectrophotometric method which was based on a Fourier self-deconvolution (FSD) method coupled with the isoabsorptive point for determination of TAD and DAP in pharmaceutical dosage form. We also applied an SPE process based on MT-MIP designed particles, assisting in the analysis of both drugs in counterfeit food samples. The SPE process and the UV spectroscopic methodology were assessed regarding their greenness using the pioneering green analytical procedure index (GAPI), analytical greeness including sample preparation (AGREEprep) and AGREE tools. The synthesized MT-MIP particles were characterized by scanning electron microscopy and energy-dispersive x-ray spectroscopy. Results: The suggested spectrophotometric methods revealed a wide linear concentration range of 2–50 µg/mL with lower LODs in the range of 0.604–0.994 µg/mL. Additionally, the suggested method demonstrated the utmost sensitivity and eco-friendliness for their target in its mixed dosage form and counterfeit food products. Conclusion: The SPE process and the developed analytical UV spectroscopic methodology were validated as per the ICH guidelines, and were found to be suitable for overseeing some counterfeiting activities in commercially available honey and instant coffee aphrodisiac products. Highlights: An SPE method based on MT-MIP magnetic-based polymer and a UV spectroscopic method were successfully developed for analysis of TAD and DAP in different matrices.


  • Computer-Aided Design of Eco-Friendly Imprinted Polymer Decorated Sensors Augmented by Self-Validated Ensemble Modeling Designs for the Quantitation of Drotaverine Hydrochloride in Dosage Form and Human Plasma

    by Aziza E. Mostafa, Maya S Eissa, Ahmed Elsonbaty, Khaled Attala, Randa A. Abdel Salam, Ghada M. Hadad, Mohamed A Abdelshakour

    Computationally-designed molecular imprinted polymers (MIP) incorporation into electrochemical sensors has many advantages to the performance of the designed sensors. The innovative self-validated ensemble modeling (SVEM) approach is a smart machine learning-based technique that enabled the design of more accurate predictive models utilizing smaller data sets. The novel SVEM experimental design methodology is exploited here exclusively to optimize the composition of four eco-friendly PVC membranes augmented by a computationally designed magnetic molecularly imprinted polymer to quantitatively determine drotaverine hydrochloride in its combined dosage form and human plasma. Besides, the application of hybrid computational simulations such as molecular dynamics and quantum mechanical calculations (MD/QM) is a time-saving and eco-friendly provider for the tailored design of the MIP particles. Here, for the first time, the predictive power of machine learning is assembled with computational simulations to develop four PVC-based sensors decorated by computationally designed MIP particles utilizing four different experimental designs known as central composite, SVEM-LASSO, SVEM-FWD, and SVEM-PFWD. The pioneering Agree approach further assessed the greenness of the analytical methods, proving their eco-friendliness. The proposed sensors showed decent Nernstian responses towards drotaverine hydrochloride in the range of (58.60—59.09 mV/decade) with a linear quantitative range of (1 x 10−7—1 x 10−2 M) and limits of detection in the range of (9.55 x 10−8 – 7.08 x 10−8 M). Moreover, the proposed sensors showed ultimate eco-friendliness and selectivity for their target in its combined dosage form and spiked human plasma. The proposed sensors were validated as per IUPAC recommendations proving their sensitivity and selectivity for drotaverine determination in dosage form and human plasma. This work presents the first ever application of both the innovative SVEM designs and MD/QM simulations in the optimization and fabrication of drotaverine-sensitive and selective MIP-decorated PVC sensors.


  • Acute toxic effects of new synthetic cannabinoid on brain: Neurobehavioral and Histological: Preclinical studies

    by Shrouk Mohamed Ali, Eman Kolieb, Samar Imbaby, Abeer M. Hagras, Horeya Erfan Korayem Arafat, Eman Mohamed Kamel, Mohamed A. Abdelshakour, Maha Ismail Mohammed Ali


  • Monitoring of Organophosphorus and Organochlorine Pesticides Residues in Freshwater of Suez Canal Region, Egypt by Gas Chromatography

    by Mohamed Abdel Shakour, Randa Abdel Salam, Ghada Hadad, Diaa T.A. Yousef

    Water is very essential for the human, animal and agriculture existence. Water supplies are exposed to contamination by different sources from industrial, pharmaceutical, agricultural and natural origins. Traditionally, analytical methods based on gas chromatography or liquid chromatography were used tomonitor water quality. The objective of this research was to monitor some OPPs and OCPs pesticides residues in Ismailia freshwater canal in the three governorates (Ismailia, Port Said and Suez) over a period started from May 2008 to January 2011 by GC using flame photometric detector (FPD) for OPPs and electron capture detector for OCPs pesticides. No OCPs pesticides residues were found in freshwater at quantification level of the GC method, however OPPs pesticides methamidophos (1.97 ngL-1) and ethoprophos (1.73 ngL-1) were detected in freshwater samples collected from Port Said governorate in February 2009.